Search bioRxiv⌕ Search

Biology subjects

Trobaugh, J. W.

Publications and source records attributed to Trobaugh, J. W..

6 recordsLinked to original sources

Unconstrained naturalistic human brain imaging and decoding with a fully wearable high-density optical system

Understanding how the brain supports complex cognition in real-world environments requires neuroimaging systems that impose minimal constraints on natural behavior. Existing high-fidelity modalities, such as functional magnetic resonance imaging (fMRI), confine participants to the scanner, while wearable alternatives sacrifice spatial resolution or cortical coverage. Here, we developed a fully untethered whole-head optical neuroimaging system that achieves high-fidelity tomographic reconstruction through dense spatial sampling, configurable source multiplexing, and high dynamic range detection. This wearable high-density diffuse optical tomography (WHD-DOT) system achieves 151 dB effective dynamic range and nearly 3000 source-detector measurements, comparable to the highest-performing fiber-based DOT systems, while maintaining wireless, battery-powered mobility. We validate WHD-DOT across three paradigms of increasing ecological complexity, ranging from standard functional localizers to naturalistic movie viewing and live piano performance. Across all paradigms, WHD-DOT produces robust, well-localized encoding, repeatable single-trial responses, and above-chance decoding of stimulus-specific dynamics. Piano performance, which requires continuous bimanual movement and an unconstrained posture, is a rigorous real-world test for a wearable neuroimaging system. By decoding song-segment identity of free piano performance at 71.1% accuracy (chance 12.5%), WHD-DOT shows that brain activity from unconstrained, real-world behavior, previously beyond reach of high-fidelity imaging, is now both measurable and decodable.

neuroscience↗

Visual Semantic Encoding and Identification of Naturalistic Movies via High-Density Diffuse Optical Tomography

Understanding how the brain represents meaning in real-world contexts is essential for both fundamental neuroscience and clinical applications. Brain encoding and decoding models from naturalistic stimuli provide a powerful window into semantic representations. Yet, existing approaches rely on a constrained scanning environment, or on conventional fNIRS, which has been limited to sparse sampling and/or block-design paradigms. Here, we tested whether high-density diffuse optical tomography (HD-DOT), an advanced high-density tomographic optical imaging method, can support semantic encoding and decoding using naturalistic movies. We collected 3.5 hours of naturalistic movie viewing data from six participants using stimuli labeled with 1,708 categories. Encoding models robustly predicted voxel-level responses, yielding single semantic category maps consistent with prior fMRI studies. In complementary decoding analyses, we showed that DOT responses captured sufficient semantic content to identify which clips participants viewed. To assess organization across individuals, we identified a shared low-dimensional semantic space that captures common semantic dimensions. Finally, clustering analyses revealed interpretable higher-order semantic dimensions like social and animate agents, objects vs natural organisms, and textural scenes, consistently mapped across the cortex. These findings demonstrate that DOT can recover distributed, high-dimensional semantic representations from naturalistic movies, bridging fMRI-level semantic mapping with the accessibility of optical imaging.

neuroscience↗

Identifying Naturalistic Movies from Human Brain Activity with High-Density Diffuse Optical Tomography

Modern neuroimaging modalities, particularly functional MRI (fMRI), can decode detailed human experiences. Thousands of viewed images can be identified or classified, and sentences can be reconstructed. Decoding paradigms often leverage encoding models that reduce the stimulus space into a smaller yet generalizable feature set. However, the neuroimaging devices used for detailed decoding are non-portable, like fMRI, or invasive, like electrocorticography, excluding application in naturalistic use. Wearable, non-invasive, but lower-resolution devices such as electroencephalography and functional near-infrared spectroscopy (fNIRS) have been limited to decoding between stimuli used during training. Herein we develop and evaluate model-based decoding with high-density diffuse optical tomography (HD-DOT), a higher-resolution expansion of fNIRS with demonstrated promise as a surrogate for fMRI. Using a motion energy model of visual content, we decoded the identities of novel movie clips outside the training set with accuracy far above chance for single-trial decoding. Decoding was robust to modulations of testing time window, different training and test imaging sessions, hemodynamic contrast, and optode array density. Our results suggest that HD-DOT can translate detailed decoding into naturalistic use.

bioengineering↗

Anatomical Modeling and Optimization of Speckle Contrast Optical Tomography

Traditional methods for mapping cerebral blood flow (CBF), such as positron emission tomography and magnetic resonance imaging, offer only isolated snapshots of CBF due to scanner logistics. Speckle contrast optical tomography (SCOT) is a promising optical technique for mapping CBF. However, while SCOT has been established in mice, the method has not yet been demonstrated in humans - partly due to a lack of anatomical reconstruction methods and uncertainty over the optimal design parameters. Herein we develop SCOT reconstruction methods that leverage MRI-based anatomical head models and finite-element modeling of the SCOT forward problem (NIRFASTer). We then simulate SCOT for CBF perturbations to evaluate sensitivity of imaging performance to exposure time and SD-distances. We find image resolution comparable to intensity-based diffuse optical tomography at superficial cortical tissue depth ([~]1.5 cm). Localization errors can be reduced by including longer SD-measurements. With longer exposure times speckle contrast decreases, however, noise decreases faster, resulting in a net increase in SNR. Specifically, extending exposure time from 10s to 10ms increased SCOT SNR by 1000X. Overall, our modeling methods provide anatomically-based image reconstructions that can be used to evaluate a broad range of tissue conditions, measurement parameters, and noise sources and inform SCOT system design.

neuroscience↗

Ultra-high density imaging arrays for diffuse optical tomography of human brain improve resolution, signal-to-noise, and information decoding

Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing ([~]13 mm) than sparse fNIRS ([~]30 mm) and therefore provide higher image quality, with spatial resolution [~]1/2 that of fMRI. Herein, simulations indicated reducing inter-optode spacing to 6.5 mm would further improve image quality and noise-resolution tradeoff, with diminishing returns below 6.5 mm. We then constructed an ultra-high-density DOT system (6.5-mm spacing) with 140 dB dynamic range that imaged stimulus-evoked activations with 30-50% higher spatial resolution and repeatable multi-focal activity with excellent agreement with participant-matched fMRI. Further, this system decoded visual stimulus position with 19-35% lower error than previous HD-DOT, throughout occipital cortex.

bioengineering↗

Multi-Mode Fiber-Based Speckle Contrast Optical Spectroscopy: Analysis of Speckle Statistics

Speckle contrast optical spectroscopy/tomography (SCOS/T) provides a real-time, non-invasive, and cost-efficient optical imaging approach to mapping of cerebral blood flow. By measuring many speckles (n>>10), SCOS/T has increased signal-to-noise ratio relative to diffuse correlation spectroscopy, which measures one or a few speckles. However, the current free-space SCOS/T designs are not ideal for large field-of-view imaging in humans because the curved head contour cannot be readily imaged with a single flat sensor and hair obstructs optical access. Herein we evaluate the feasibility of using cost-efficient multi-mode fiber (MMF) bundles for use in SCOS/T systems. One challenge with speckle contrast measurements is the potential for confounding noise sources (e.g., shot noise, readout noise) to contribute to the standard deviation measure and corrupt the speckle contrast measure that is central to the SCOS/T systems. However, for true speckle measurements, the histogram of pixel intensities from light interference follows a non-Gaussian distribution, specifically a gamma distribution with non-zero skew, whereas most noise sources have pixel intensity distributions that are Gaussian. By evaluating speckle data from static and dynamic targets imaged through MMF, we use histograms and statistical analysis of pixel histograms to evaluate whether the statistical properties of the speckles are retained. We show that flow-based speckle can be distinguished from static speckle and from sources of system noise through measures of skew in the pixel intensity histograms. Finally, we illustrate in humans that MMF bundles relay blood flow information. (C) 2022 Optica Publishing Group

bioengineering↗