Search bioRxiv⌕ Search

Biology subjects

Tinning, P. W.

Publications and source records attributed to Tinning, P. W..

5 recordsLinked to original sources

A simple computational method to increase axial contrast in multi-wavelength interference microscopy

Multi-wavelength standing wave (SW) microscopy and interference reflection microscopy (IRM) are powerful techniques that use optical interference to study topographical structure. However, the use of more than two wavelengths to image the complex cell surface results in complicated topographical maps and it can be difficult to resolve the three-dimensional contours. We present a simple image processing method to reduce the thickness and spacing of antinodal fringes in multi-wavelength interference microscopy by up to a factor of two to produce clearer and more precise topographical maps of cellular structures. We first demonstrate this improvement using model non-biological specimens, and we subsequently demonstrate the benefit of our method for reducing the ambiguity of surface topography and revealing obscured features in live and fixed cell specimens.

biophysics↗

Benchmarking thiolate driven photoswitching of cyanine dyes

Carbocyanines are among the best performing dyes in singlemolecule localization microscopy (SMLM), but their performance critically relies on optimized photoswitching buffers. As the chemical buffer composition controls the transitions between non-fluorescent off- and fluorescent on-states, it is ultimately linked to the maximum achievable resolution. Here, we describe a workflow for screening optimal buffer conditions for single-molecule photoswitching. This is achieved by creating an intensity gradient within the field of view using a single micro-electromechanical systems (MEMS) mirror in the excitation path of the wide-field setup. Photon budget, on-state and off-state lifetimes are studied for different concentrations of mercatoethylamine (MEA) and buffer pH values. Both of MEA concentration and buffer pH determine the amount of thiolate, which is the main requirement for carbocyanine dye photoswitching. We show that thiolate acts as a concentration bandpass filter for the maximum achievable resolution and determine a minimum thiolate concentration of [~]1 mM is necessary to facilitate SMLM measurements. We also identify a concentration bandwidth of 1-16 mM in which the photoswitching performance can be balanced between high molecular brightness and high off-time to on-time ratios. Furthermore, we monitor the performance of the popular oxygen scavenger system based on glucose and glucose oxidase over time and show simple measures to avoid acidification during prolonged measurements. Finally, the impact of buffer settings is quantitatively tested on the distribution of the glucose transporter protein 4 within the plasma membrane of adipocytes. Our work provides a general strategy for achieving optimal resolution in SMLM with relevance for the development of novel buffers and dyes.

biophysics↗

Miniaturised structured illumination microscopy using two 3-axis MEMS micromirrors

We present the development and performance characterisation of a novel structured illumination microscope (SIM) in which the grating pattern is generated using two optical beams controlled via 2 micro-electro-mechanical system (MEMS) three-axis scanning micromirrors. The implementation of MEMS micromirrors to accurately and repeatably control angular, radial and phase positioning delivers flexible control of the fluorescence excitation illumination, with achromatic beam delivery through the same optical path, reduced spatial footprint and cost-efficient integration being further benefits. Our SIM architecture enables the direct implementation of multi-colour imaging in a compact and adaptable package. The two-dimensional SIM system approach is enabled by a pair of 2 mm aperture electrostatically actuated three-axis micromirrors having static angular tilt motion along the x- and y- axes and static piston motion along the z-axis. This allows precise angular, radial and phase positioning of two optical beams, generating a fully controllable spatial interference pattern at the focal plane by adjusting the positions of the beam in the back-aperture of a microscope objective. This MEMS-SIM system was applied to fluorescent bead samples and cell specimens, and was able to obtain a variable lateral resolution improvement between 1.3 and 1.8 times the diffraction limited resolution.

cell biology↗

An evaluation of multi-excitation-wavelength standing-wave fluorescence microscopy (TartanSW) to improve sampling density in studies of the cell membrane and cytoskeleton

Conventional standing-wave (SW) fluorescence microscopy uses a single wavelength to excite fluorescence from the specimen, which is normally placed in contact with a first surface reflector. The resulting excitation SW creates a pattern of illumination with anti-nodal maxima at multiple evenly-spaced planes perpendicular to the optical axis of the microscope. These maxima are approximately 90 nm thick and spaced 180 nm apart. Where the planes intersect fluorescent structures, emission occurs, but between the planes are non-illuminated regions which are not sampled for fluorescence. We evaluate a multi-excitation-wavelength SW fluorescence microscopy (which we call TartanSW) as a method for increasing the density of sampling by using SWs with different axial periodicities, to resolve more of the overall cell structure. The TartanSW method increased the sampling density from 50% to 98% over seven anti-nodal planes, with no notable change in axial or lateral resolution compared to single-excitation-wavelength SW microscopy. We demonstrate the method with images of the membrane and cytoskeleton of living and fixed cells.

cell biology↗

A 340/380 nm Light Emitting Diode Illuminator For Fura-2 AM Ratiometric Ca2+ Imaging Of Live Cells With Better Than 5 nM Precision

We report the first demonstration of a fast wavelength-switchable 340/380 nm light emitting diode (LED) illuminator for Fura-2 ratiometric Ca2+ imaging of live cells. The LEDs closely match the excitation peaks of bound and free Fura-2 and enables the precise detection of cytosolic Ca2+ concentrations, which is only limited by the Ca2+ response of Fura-2. Using this illuminator, we have shown that Fura-2 acetoxymethyl ester (AM) concentrations as low as 250 nM can be used to detect induced Ca2+ events in tsA-201 cells and while utilizing the 150 s switching speeds available, it was possible to image spontaneous Ca2+ transients in hippocampal neurons at a rate of 24.39 Hz that were blunted or absent at typical 0.5 Hz acquisition rates. Overall, the sensitivity and acquisition speeds available using this LED illuminator significantly improves the temporal resolution that can be obtained in comparison to current systems and supports optical imaging of fast Ca2+ events using Fura-2.

neuroscience↗