Search bioRxiv⌕ Search

Biology subjects

Tate, S.

Publications and source records attributed to Tate, S..

5 recordsLinked to original sources

Performance Characteristics of Zeno Trap Scanning DIA for Sensitive and Quantitative Proteomics at High Throughput

Proteomic experiments, particularly those addressing dynamic proteome properties, time series, or genetic diversity, require the analysis of large sample numbers. Despite significant advancements in proteomic technologies in recent years, further improvements are needed to accelerate measurement and enhance proteome coverage and quantitative performance. Previously, we demonstrated that incorporating a scanning MS2 dimension into data-independent acquisition methods (Scanning SWATH, or more generally scanning DIA) but also ion trapping, improves analytical depth and quantitative performance, especially in proteomic methods using fast chromatography. Here, we evaluate the scanning DIA approach combined with ion trapping via the Zeno trap in a method termed ZT Scan DIA, using a prototype Zeno trap Q-TOF instrument (SCIEX). Applying this method to established proteome standards across various analytical setups, enabling intermediate to high sample throughput, we observed a 30-40% increase in identified precursors. This enhancement extended to overall protein identification and precise quantification. Furthermore, ZT Scan DIA effectively eliminated quantitative bias, as demonstrated by its ability to deconvolute proteomes in multi-species mixtures. We propose that ZT Scan DIA can be used for a broad range of applications in proteomics, particularly in studies requiring high quantitative precision with low sample input and high-throughput workflows. Significance StatementThe advent of faster DIA proteomics methods paved the way for investigating increasingly large sample series, including patient cohorts and strain collections containing thousands of samples. Yet, recent improvements in DIA methods still entailed compromises between analytical sensitivity and selectivity. The presented combination of a scanning quadrupole with fast ion trapping in a Zeno Trap, coined ZT Scan DIA increases quantitative precision and accuracy in fast proteomics experiments. These features of ZT Scan DIA may benefit applications that deal with low input samples and high-throughput proteomic workflows in biomedical cohort studies and systems biology.

systems biology↗

Design and Biological Activity of a Novel Brain Penetrant Urea Compound Against Glioblastoma

Glioblastoma (GBM) remains the most lethal primary brain tumor, largely due to therapy-resistant glioma stem cells (GSCs) and the ability of non-stem cells to dedifferentiate under therapeutic pressure. We developed MXC-017, a novel urea-based compound that crosses the blood-brain-barrier, directly targets GSCs, and prevents radiation-induced GSC formation. Using click chemistry pull-down and mass spectrometry, we identified vimentin as the target of MXC-017, further validated by in silico docking. Global transcriptomic profiling (bulk RNA-seq) and single-cell RNA-seq analyses revealed MXC-017s efficacy with minimal off-target effects, supported by metabolic and kinome assays. Normal cell toxicity was negligible in fibroblasts, microglia, astrocytes, and murine neural progenitors. Maximum tolerated dose was identified and we observed significantly extended median survival in 17 PDOX GBM models when treated with MXC-017 plus radiation, benchmarked against standard-of-care temozolomide. These findings underscore the therapeutic potential of vimentin-targeting agents to overcome radiation resistance and improve outcomes for GBM patients. Statement of SignificanceGlioblastomas distinctive nature and the blood-brain barrier hamper therapies targeting therapy-resistant GSCs. We developed a novel urea-based agent that crosses the barrier, targets GSCs, and prevents radiation-induced GSC formation. With minimal off-target effects, reduced toxicity, and superior survival in PDOX models, it offers potential to improve outcome in GBM.

neuroscience↗

Synergistic effects of PARP inhibitors by Schlafen 11 and BRCA2-deficiency through accumulation of single-strand DNA gaps behind a fork

Poly (ADP-ribose) polymerase (PARP) inhibitors (PARPis) induce synthetic lethality in breast cancer gene (BRCA)-deficient tumors. Besides the original model proposed by accumulation of double-strand DNA breaks due to the impaired homologous recombination, accumulation of single-strand DNA (ssDNA) gaps due to impaired BRCA-mediated Okazaki fragment processing has emerged as an alternative mechanism of synthetic lethality. Accordingly, PARPis induce ssDNA gaps behind a replication fork in BRCA-deficient cells. Schlafen 11 (SLFN11), a member of the SLFN family, binds replication protein A (RPA)-coated ssDNA gaps and sensitizes cancer cells to DNA-damaging anticancer agents. These facts motivated us to examine the combinational effects of SLFN11 and BRCA-deficiency on PARPis sensitivity. Here, we show that SLFN11 and BRCA2-deficiency synergistically increased sensitivity to PARPis (talazoparib, niraparib, olaparib, and veliparib) at specific concentrations, where SLFN11 alone showed marginal effects. Using chromatin-bound proteins and alkaline BrdU comet assays in human cancer cells, we revealed that ssDNA gaps induced by PARPis were increased by SLFN11 or BRCA2-deficiency and that the combination of the two had the greatest effect. SLFN11 was recruited to and colocalized with chromatin-bound RPA2 under PARPis. SLFN11 recruited around a fork under DNA damage blocked replication, whereas SLFN11 recruited behind a fork under PARPis did not. Chromatin recruitment of SLFN11 and RPA2 was attenuated by the MRE11 inhibitor mirin. Hence, our studies showed that BRCA2-deficiency increased ssDNA gaps behind a fork under PARPis treatment, where SLFN11 bound and further increased the gaps. Our findings provide a mechanistic understanding of favorable responses to PARPis in SLFN11-proficient and BRCA-deficient tumors. SignificanceThis study reveals how SLFN11 enhances the antitumor effects of PARP inhibitors in BRCA2-deficient cancer cells and highlights the importance of analyzing SLFN11 expression in addition to BRCA analysis in clinical practice.

cancer biology↗

High-throughput proteomics of nanogram-scale samples with Zeno SWATH DIA

The ability to conduct high-quality proteomic experiments in high throughput has opened new avenues in clinical research, drug discovery, and systems biology. Next to an increase in quantitative precision, recent developments in high-throughput proteomics have also gained proteomic depth, to the extent that earlier gaps between classic and high-throughput experiments have significantly narrowed. Here we introduce and benchmark Zeno SWATH, a data-independent acquisition technique that employs a linear ion trap pulsing (Zeno trap pulsing) in order to increase proteomic depth and dynamic range in proteomic experiments. Combined with the high acquisition speed, these gains in sensitivity are particularly attractive for conducting high-throughput proteomics experiments with high chromatographic flow rates and fast gradients. We demonstrate that when combined with either micro-flow- or analytical-flow-rate chromatography, Zeno SWATH increases protein identification in complex samples 5- to 10-fold when compared to current SWATH acquisition methods on the same instrument. Using 20-min micro-flow chromatography, Zeno SWATH identified > 6,000 proteins from a 62.5 ng load of human cell lysate with more than 5,000 proteins consistently quantified in triplicate injections with a median CV of 6%. Using 5-min analytical-flow-rate chromatography (800 {micro}l/min), Zeno SWATH identified 4,907 proteins from a triplicate injection of 2 {micro}g of a human cell lysate; or more than 3,000 proteins from 250 ng tryptic digest. Zeno SWATH hence facilitates precise proteomic experiments with small sample amounts using a fast and robust high flow-rate chromatographic method, broadening the application space that requires precise proteomic experiments on a large scale.

biochemistry↗

ScanningSWATH enables ultra-fast proteomics using high-flow chromatography and minute-scale gradients

Bridging genotype to phenotype, the proteome has increasingly become of major importance to generate large, longitudinal sample series for data-driven biology and personalized medicine. Major improvements in laboratory automation, chromatography and software have increased the scale and precision of proteomics. So far missing are however mass spectrometric acquisition techniques that could deal with very fast chromatographic gradients. Here we present scanning SWATH, a data-independent acquisition (DIA) method, in which the DIA-typical stepwise windowed acquisition is replaced by a continuous movement of the precursor isolation window. Scanning SWATH accelerates the duty cycles to a few hundreds of milliseconds, and enables precursor mass assignment to the MS2 fragment traces for improving true positive precursor identification in fast proteome experiments. In combination with 800 {micro}L/min high-flow chromatography, we report the quantification of 270 precursors per second, increasing the precursor identifications by 70% or more compared to previous methods. Scanning SWATH quantified 1,410 Human protein groups in conjunction with chromatographic gradients as fast as 30 seconds, 2,250 with 60-second gradients, and 4,586 in conjunction with 5-minute gradients. At high quantitative precision, our method hence increases the proteomic throughput to hundreds of samples per day per mass spectrometer. Scanning SWATH hence enables a broad range of new proteomic applications that depend on large numbers of cheap yet quantification precise proteomes.

systems biology↗