Search bioRxiv⌕ Search

Biology subjects

Taskin, H. O.

Publications and source records attributed to Taskin, H. O..

3 recordsLinked to original sources

Temporal sensitivity for achromatic and chromatic flicker across the visual cortex

The retinal ganglion cells (RGCs) receive different combinations of L, M, and S cone inputs and give rise to one achromatic and two chromatic post-receptoral channels. Beyond the retina, RGC outputs are subject to filtering and normalization along the geniculo-striate pathway, ultimately producing the properties of human vision. The goal of the current study was to determine temporal sensitivity across the three post-receptoral channels in subcortical and cortical regions involved in vision. We measured functional magnetic resonance imaging (MRI) responses at 7 Tesla from three participants (two males, one female) viewing a high-contrast, flickering, spatially-uniform wide field (~140{degrees}). Stimulus flicker frequency varied logarithmically between 2 and 64 Hz and targeted the L+M+S, L-M, and S-[L+M] cone combinations. These measurements were used to create temporal sensitivity functions of primary visual cortex (V1) across eccentricity, and spatially averaged responses from lateral geniculate nucleus (LGN), V2/V3, hV4, and V3A/B. Functional MRI responses reflected known properties of the visual system, including higher peak temporal sensitivity to achromatic vs. chromatic stimuli, and low-pass filtering between the LGN and V1. Peak temporal sensitivity increased across levels of the cortical visual hierarchy. Unexpectedly, peak temporal sensitivity varied little across eccentricity within area V1. Measures of adaptation and distributed pattern activity revealed a subtle influence of 64 Hz achromatic flicker in area V1, despite this stimulus evoking only a minimal overall response. Comparison of measured cortical responses to a model of integrated retinal output to our stimuli demonstrates that extensive filtering and amplification is applied to post-retinal signals. Significance StatementWe report the temporal sensitivity of human visual cortex across the three canonical post-receptoral channels from central vision to the far periphery. Functional MRI measurements of responses from the LGN, V1, and higher visual cortical areas demonstrate modification of temporal sensitivity across the visual hierarchy. This includes amplification of chromatic signals between the LGN and V1, and an increase in peak temporal sensitivity in visual areas beyond V1. Within V1, we find a surprising stability of peak temporal sensitivity in the periphery for all three post-receptoral directions. Comparison of our results to a model of retinal output demonstrates the presence of substantial post-retinal filtering, yielding greater uniformity of responses across area V1 than would be predicted from unmodified retinal signals.

neuroscience↗

Retinal ganglion cell endowment is correlated with optic tract fiber cross section, not density

There is substantial variation between healthy individuals in the number of retinal ganglion cells (RGC) in the eye, with commensurate variation in the number of axons in the optic tracts. Fixel-based analysis of diffusion MR produces estimates of fiber density (FD) and cross section (FC). Using these fixel measurements along with retinal imaging, we asked if individual differences in RGC tissue volume are correlated with individual differences in FD and FC measurements obtained from the optic tracts, and subsequent structures along the cortical visual pathway. We find that RGC endowment is correlated with optic tract FC, but not with FD. RGC volume had a decreasing relationship with measurements from subsequent regions of the visual system (LGN volume, optic radiation FC/FD, and V1 surface area). However, we also found that the variations in each visual area were correlated with the variations in its immediately adjacent visual structure. We only observed these serial correlations when FC is used as the measure of interest for the optic tract and radiations, but no significant relationship was found when FD represented these white matter structures. From these results, we conclude that the variations in RGC endowment, LGN volume, and V1 surface area are better predicted by the overall cross section of the optic tract and optic radiations as compare to the intra-axonal restricted signal component of these white matter pathways. Additionally, the presence of significant correlations between adjacent, but not distant, anatomical structures suggests that there are multiple, local sources of anatomical variation along the visual pathway.

neuroscience↗

Persistent horizontal and vertical, MR-induced nystagmus in resting state Human Connectome Project data

ObjectiveStrong magnetic fields from magnetic resonance (MR) scanners induce a Lorentz force that contributes to vertigo and persistent nystagmus. Prior studies have reported a predominantly horizontal direction for healthy subjects in a 7 Tesla (T) MR scanner, with slow phase velocity (SPV) dependent on head orientation. Less is known about vestibular signal behavior for subjects in a weaker, 3T magnetic field, the standard strength used in the Human Connectome Project (HCP). The purpose of this study is to characterize the form and magnitude of nystagmus induced at 3T. MethodsForty-two subjects were studied after being introduced head-first, supine into a Siemens Prisma 3T scanner. Eye movements were recorded in four separate acquisitions over 20 minutes. A biometric eye model was fit to the recordings to derive rotational eye position and then SPV. An anatomical template of the semi-circular canals was fit to the T2 anatomical image from each subject, and used to derive the angle of the B0 magnetic field with respect to the vestibular apparatus. ResultsRecordings from 37 subjects yielded valid measures of eye movements. The population-mean SPV {+/-} SD for the horizontal component was -1.38 {+/-} 1.27 deg/sec, and vertical component was -0.93 {+/-} 1.44 deg/sec, corresponding to drift movement in the rightward and downward direction. Although there was substantial inter-subject variability, persistent nystagmus was present in half of subjects with no significant adaptation over the 20 minute scanning period. The amplitude of vertical drift was correlated with the roll angle of the vestibular system, with a non-zero vertical SPV present at a 0 degree roll. InterpretationNon-habituating vestibular signals of varying amplitude are present in resting state data collected at 3T.

neuroscience↗