Search bioRxivSearch

Biology subjects

Svirsky, M. A.

Publications and source records attributed to Svirsky, M. A..

2 recordsLinked to original sources

Locus coeruleus activity improves cochlear implant performance

Cochlear implants are neuroprosthetic devices that can provide hearing to deaf patients1. Despite significant benefits offered by cochlear implants, there are highly variable outcomes in how quickly hearing is restored and perceptual accuracy after months or years of use2,3. Cochlear implant use is believed to require neuroplasticity within the central auditory system, and differential engagement of neuroplastic mechanisms might contribute to outcome variability4-7. Despite extensive studies on how cochlear implants activate the auditory system4,8-12, our understanding of cochlear implant-related neuroplasticity remains limited. One potent factor enabling plasticity is the neuromodulator norepinephrine from the brainstem locus coeruleus. Here we examined behavioral responses and neural activity in locus coeruleus and auditory cortex of deafened rats fitted with multi-channel cochlear implants. Animals were trained on a reward-based auditory task, with considerable individual differences of learning rates and maximum performance. Photometry from locus coeruleus predicted when implanted subjects would begin responding to sounds and longer-term perceptual accuracy, which were augmented by optogenetic locus coeruleus stimulation. Auditory cortical responses to cochlear implant stimulation reflected behavioral performance, with enhanced responses to rewarded stimuli and decreased distinction between unrewarded stimuli. Adequate engagement of central neuromodulatory systems is thus a potential clinically-relevant target for optimizing neuroprosthetic device use.

neuroscience

Reducing interaural tonotopic mismatch preserves binaural unmasking in cochlear implant simulations of single-sided deafness

Binaural unmasking, a key feature of normal binaural hearing, refers to the improved intelligibility of masked speech by adding masking noise that facilities perceived spatial separation of target and masker. A question particularly relevant for cochlear implant users with single-sided deafness (SSD-CI) is whether binaural unmasking can still be achieved if the additional masking is distorted. Adding the CI restores some aspects of binaural hearing to these listeners, although binaural unmasking remains limited. Notably, these listeners may experience a mismatch between the frequency information perceived through the CI and that perceived by their normal hearing ear. Employing acoustic simulations of SSD-CI with normal hearing listeners, the present study confirms a previous simulation study that binaural unmasking is severely limited when interaural frequency mismatch between the input frequency range and simulated place of stimulation exceeds 1-2 mm. The present study also shows that binaural unmasking is largely retained when the input frequency range is adjusted to match simulated place of stimulation, even at the expense of removing low-frequency information. This result bears implication for the mechanisms driving the type of binaural unmasking of the present study, as well as for mapping the frequency range of the CI speech processor in SSD-CI users.

neuroscience