Search bioRxiv⌕ Search

Biology subjects

Stewart, H.

Publications and source records attributed to Stewart, H..

At least 19 recordsLinked to original sources

Beyond Navigation - Tissue-contacting Fluorescent Lifetime Imaging reveals a pathology-linked lung cancer phenotype at the point of biopsy

Background: Accurate sampling of suspected peripheral lung cancers depends on access to the lesion and confirmation that the biopsy tool is in contact with target tissue. Current bronchoscopic navigation and imaging techniques can guide instruments to a target but do not provide real-time biological confirmation at the point of sampling. Fluorescence lifetime imaging microscopy (FLIM) provides molecular contrast by measuring fluorescence decay - how long photons continue to be emitted from fluorescent molecules. In the Precision Lung clinical study (ISRCTN15093468), the Prothea Imaging System (Generation 1) identified a candidate tumour-associated phenotype of spatially overlapped low fluorescence lifetime and low intensity (LLLI) from in-vivo imaging. We used this observation as the basis for a reverse-translational study to determine whether the LLLI phenotype is linked to cancer pathology; reproducible with the Imaging System (Generation 2); and distinguishable from normal lung tissue. Methods: Previously reported Precision Lung findings were used as the clinical starting observation and were not re-analysed. Validation was then performed using: (i) pathology linked benchtop FLIM of early-stage non-small-cell lung tissue microarrays encompassing malignant cell clusters of approximately 300 um2, matched to the EoT imaging scale; (ii) five sequential fresh lung-cancer resections imaged at tumour and comparator regions, including visibly blood-rich contact sites, using the (Generation 2) Imaging System; and (iii) systematic mapping of two ventilated non-cancer donor lungs, one from a smoker and one from a non-smoker, across all available lobes. The LLLI phenotype was defined as spatial co-localisation of low intensity and short lifetime. Results: Using a real time fibre based FLIM system, capable of deployment through a working channel of a bronchoscope, the LLLI tumour phenotype was optically identified in freshly resected tumour tissue. The same phenotype was identified in fixed tissue samples with known pathology, and with images taken in the Precision Lung clinical study. Whole human lung controls did not show evidence of the tumour phenotype. Conclusions: This evidence forms a reverse-translational chain that supports the concept of the Prothea Imaging System - as a platform that confirms that the tool is in contact with a region of cancer in the lesion, while preserving continuous access for biopsy or intervention.

cancer biology↗

Endomicroscopic fluorescence lifetime imaging enables molecular detection and targeted sampling in the distal human lung

PurposeAccurate molecular characterisation of infection and inflammation within the distal human lung remains challenging, particularly in critically ill patients, due to limited access to the alveolar space and delayed diagnostic workflows. Molecular imaging approaches capable of real-time detection and targeted sampling could substantially improve diagnostic precision and the future translational development of molecular imaging probes and therapeutics. MethodsIn a preclinical setting, we evaluated a clinic-ready endomicroscopic fluorescence lifetime imaging microscopy (eFLIM) platform combined with molecularly targeted SmartProbes for in situ detection of bacteria and activated neutrophils in the distal human lung. A multifunctional 1.9-mm diameter imaging and sampling catheter (Eyes on Target; EoT) enabled real-time fluorescence intensity and lifetime imaging alongside directed alveolar microlavage via a 1.2-mm working channel. Fluorescence intensity and lifetime signatures of Gram-negative bacteria, Gram-positive bacteria, and activated neutrophils were characterised using three wash-free SmartProbes: NBD-PMX, Merocy-Van, and a neutrophil activation probe (NAP). Imaging and sampling performance were assessed in ventilated ex vivo human lungs. ResultsEoT reliably navigated to alveolar regions across all lung lobes in both phantom and ventilated human lung models. eFLIM distinguished alveolar microanatomy and enabled probe-specific molecular detection within the distal lung. Increased NBD-PMX signal was detected in Escherichia coli-instilled lobes, while Merocy-Van lifetime signatures selectively identified Staphylococcus aureus-instilled regions. Activated neutrophils were detected throughout lung tissue following NAP administration. Directed alveolar microlavage enabled recovery of cellular material and bacterial DNA from imaged regions for downstream analysis. ConclusioneFLIM using EoT combined with molecular SmartProbes enables real-time molecular imaging and targeted sampling within the distal human lung. This platform provides a translatable approach for evaluating infection and inflammation at the alveolar level and supports the clinical development of molecular imaging probes for pulmonary disease.

microbiology↗

High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics

Tandem mass tags (TMT) allow highly multiplexed and thus high-throughput, precisely quantitative proteomic analysis. Incorporation of additional deuterated reporter channels has near-doubled the multiplexation achieved with Thermo Scientific TMTpro reagents from 18 to 35-plex but requires extremely high [~]100k analyzer resolving power at m/z 128 to differentiate and quantify reporter ion channels, far beyond any single reflection time-of-flight analyzer, and exceeding the multi-reflection Thermo Scientific Astral analyzer in its standard operation. A multi-pass mode of Astral operation has been developed for the Thermo Scientific Orbitrap Astral Zoom mass spectrometer that triples the ion path to 90 m, more than doubling resolving power for a narrow m/z range. This "TMT HR mode" has been integrated into a new method of TMT proteomic analysis that splits regular MS2 analysis of labeled peptides into paired measurements comprising wide mass range scans for peptide identification, and TMT HR mode scans for reporter ion quantification. The method has been shown to accurately quantify 32-plex labeled HeLa protein lysate and provide far greater depth of analysis as state-of-the-art Orbitrap-only methods, while analysis of 11-plex labeled yeast showed no analytical depth sacrificed vs regular Orbitrap Astral TMT analysis. Further comparative measurements of a 2-cell line 35-plex sample demonstrated greater analytical depth, and similar quantitative precision, to "gold standard" Orbitrap MS3 methods.

biochemistry↗

Genetic factors driving multi-host infection in a core member of the root mycobiota

Core members of the fungal root microbiota include pathogens capable of colonizing multiple hosts, yet the underlying genetic determinants remain unknown. We report that Plectosphaerella cucumerina is a core member of the Arabidopsis thaliana root microbiota displaying high pathogenic potential and multi-host colonization capabilities. Establishment of a Plectosphaerella reference culture collection, followed by whole-genome sequencing of 72 strains reveals subtle phenotypic and genotypic variation that associate with fungal phylogeny, but not host plant identity. Transcriptome profiling of a model P. cucumerina isolate in roots of multiple hosts identifies core and host-specific fungal processes linked to carbon catabolism and root cell wall deconstruction of the hosts. A fungal gene encoding a candidate {beta}-1,3-glucanase (GH64) was identified as a key genetic factor driving infection and disease in plants that diverged 110 million years ago. The gene is enriched in plant-colonizing fungi and consistently functions as a disease determinant in the root pathogen Colletotrichum incanum. We conclude that diverse and tunable fungal repertoires of carbohydrate-active enzymes act as disease determinants and drive multi-host compatibility belowground.

microbiology↗

Serological evidence of SARS-CoV-2 infection in red and fallow deer in Great Britain.

SARS-CoV-2 is the viral agent of COVID-19 disease in humans and has been shown to infect a wide range of mammals, including white-tailed deer in North America and fallow deer in the Republic of Ireland. There are six species of deer in the UK which inhabit both urban and rural areas, providing a broad interface for human-deer interaction. Little is known if British deer species act as a reservoir for zoonotic spread of consequence to human health. Here, we report a high seroprevalence of SARS-CoV-2 neutralising antibodies in British deer, adding native red deer to the list of susceptible species. 62% of fallow and 25% of red deer sampled between 2024 and 2025 from one British deer park were positive for SARS-CoV-2 infection by serology. Data suggest that deer may function as permissive, reservoir-capable hosts and highlight the risks of anthroponosis and zoonosis from unregulated human-deer contact. While there is currently no evidence to suggest that these viruses are persisting within deer populations in Great Britain, the animal origins of SARS-CoV-2 highlight the importance of appropriate and limited interactions with wildlife, to minimise transmission risks and safeguard both animal and human health.

microbiology↗

Higher-Throughput Proteome Profiling Enabled by Parallelized Pre-Accumulation and Optimized Ion Processing in the Orbitrap Astral Zoom Mass Spectrometer

High-throughput proteomics is critical for understanding biological processes, enabling large-scale studies such as biomarker discovery and systems biology. However, current mass spectrometry technologies face limitations in speed, sensitivity, and scalability for analyzing large sample cohorts. The Thermo Scientific Orbitrap Astral Zoom mass spectrometer (MS) was developed to address these limitations by improving acquisition speed, ion utilization, and spectral processing, which are all essential for advancing proteome depth in high-throughput proteomics. The Orbitrap Astral Zoom MS achieves ultra-fast MS/MS scan rates of up to 270 Hz with enhanced ion utilization through pre-accumulation, enabling the identification of [~]100,000 unique peptides and >8,400 proteins in a single 300 samples-per-day (SPD) analysis of human cell lysate. The optimized system reduces analysis time by 40%, achieves near-complete proteome coverage (>12,000 proteins) in 2.7 hours, and enables ultra-high-throughput workflows, identifying >7,000 proteins in a 500 SPD method with exceptional reproducibility (Pairwise Pearson correlations >0.99). These advancements establish the Orbitrap Astral Zoom MS as a new benchmark in proteomics, significantly enhancing speed, sensitivity, and scalability, paving the way for routine large-scale proteome studies with applications in clinical research and systems biology. TeaserHigh-Speed Human Proteome Analysis using the Orbitrap Astral Zoom Mass Spectrometer

biochemistry↗

Evaluation of an Orbitrap Astral Zoom mass spectrometer prototype for quantitative proteomics - beyond identification lists

Mass spectrometry instrumentation continues to evolve rapidly yet quantifying these advances beyond conventional peptide and protein detections remain challenging. Here, we evaluate a modified Orbitrap Astral Zoom mass spectrometer (MS) prototype and compare its performance to the standard Orbitrap Astral MS. Across a range of acquisition methods and sample inputs, the prototype instrument outperformed the standard Orbitrap Astral MS in precursor and protein identifications, ion beam utilization, and quantitative precision. To enable meaningful cross-platform comparisons, we implemented an ion calibration framework that converts signal intensity from arbitrary units to ion per second. This benchmarking strategy showed that the prototype sampled 30% more ions per peptide than the original Orbitrap Astral MS. This increase in the ion beam utilization resulted in improved sensitivity and quantitative precision. To make these metrics broadly accessible, we added new metrics to the Skyline document grid to report the number of ions measured in a spectrum at the apex of the elution peak or the sum of ions between the peak integration boundaries. Taken together, our results demonstrate the prototype Orbitrap Astral Zoom as a high-performance platform for DIA proteomics and establish a generalizable framework for evaluation of mass spectrometer performance based on the number of ions detected for each analyte. Data are available on Panorama Public and on ProteomeXchange under the identifier PXD064536.

biochemistry↗

Rapid FFR: A rapid method for obtaining Frequency Following Responses

ObjectivesFrequency-Following Responses (FFRs) are typically recorded using stimuli of 40-250 ms in duration separated by silent intervals. Because robust FFRs require averaging across approximately 3000 stimulus repetitions, conventional acquisition is time-intensive. We introduce the Rapid FFR, a technique that minimises recording time by presenting the stimulus continuously (i.e., without inter-stimulus intervals) and by averaging across individual response cycles. This study aimed to: (a) compare Rapid and Conventional FFR performance under time-matched conditions; (b) assess test-retest reliability of both methods, and (c) examine potential neural adaptation during extended Rapid FFR recordings. DesignAll participants (37 in total) were young adults with clinically normal hearing. In Experiment 1, FFRs were elicited from 16 listeners using a 128 Hz sawtooth wave presented in two ways: (1) continuously over approximately 1 minute in each polarity for the Rapid FFR and (2) as discrete tone bursts (1500 trials per polarity) for the standard FFR. Signal-to-Noise ratios (SNRs), response amplitudes, and test-retest reliability were compared across techniques. In Experiment 2, the Rapid FFR was recorded continuously from 21 listeners for nearly nine minutes to assess potential adaptation over time. ResultsThe Rapid FFR produced significantly higher SNRs than the standard FFR, reflecting improved recording efficiency. Both techniques captured inter-individual differences reliably, with comparable frequency-domain response patterns across participants. In particular, measures derived from the Rapid FFR showed strong agreement with those from the standard FFR for lower harmonics (F0-H3). Higher harmonics (H4-H7) exhibited greater variability but remained consistent between techniques. In the prolonged recording condition, FFR amplitudes remained stable over time, with no significant decline across the nine minute recording. This indicates that continuous stimulation did not result in measurable neural adaptation or response fatigue. ConclusionsThe Rapid FFR offers a time-efficient alternative to standard protocols, preserving signal fidelity and reliability while enabling shorter acquisition times. These findings suggest that the Rapid FFR is well-suited for use in populations where long recordings are challenging (e.g., in infants and the clinic) and can facilitate more extensive experimental designs within a single session. The method holds promise for advancing both research and clinical applications of the FFR. Future studies should explore its use across a broader range of sounds (in particular, dynamically varying ones) and listener groups.

neuroscience↗

Ultra-Fast Multi-Organ Proteomics Unveils Tissue-Specific Mechanisms of Drug Efficacy and Toxicity

Rapid and comprehensive analysis of complex proteomes across large sample sets is vital for unlocking the potential of systems biology. We present UFP-MS, an ultra-fast mass spectrometry (MS) proteomics method that integrates narrow-window data-independent acquisition (nDIA) with short-gradient micro-flow chromatography, enabling profiling of >240 samples per day. This optimized MS approach identifies 6,201 and 7,466 human proteins with 1- and 2-min gradients, respectively. Our streamlined sample preparation workflow features high-throughput homogenization, adaptive focused acoustics (AFA)-assisted proteolysis, and Evotip-accelerated desalting, allowing for the processing of up to 96 tissue samples in 5 h. As a practical application, we analyzed 507 samples from 13 mouse tissues treated with the enzyme-drug L-asparaginase (ASNase) or its glutaminase-free Q59L mutant, generating a quantitative profile of 11,472 proteins following drug treatment. The MS results confirmed the impact of ASNase on amino acid metabolism in solid tissues. Further analysis revealed broad suppression of anticoagulants and cholesterol metabolism and uncovered numerous tissue-specific dysregulated pathways. In summary, the UFP-MS method greatly accelerates the generation of biological insights and clinically actionable hypotheses into tissue-specific vulnerabilities targeted by ASNase.

systems biology↗

Encephalomyocarditis virus protein 2B* antagonises innate immune signalling by interacting with 14-3-3 protein family members

Encephalomyocarditis virus (EMCV) has for decades served as an important model RNA virus. Although most of the EMCV proteins are obtained via proteolytic cleavage of a long polyprotein, 2B* is expressed from a short overlapping open reading frame via an unusual protein-stimulated temporally dependent ribosomal frameshifting mechanism. The function of 2B* has not yet been characterised, though mutant viruses that are unable to express 2B* have a small plaque phenotype. Here we show that 2B* binds all seven members of the 14-3-3 protein family during virus infection. Binding is dependent on the 2B* C-terminal sequence RRNSS. IFN-{beta} and IL-6 signalling are impeded following overexpression of 2B* but not a truncated version lacking the RRNSS residues, thus suggesting a 14-3-3-dependent role for 2B* in inhibiting MAVS signalling. We also find that this function is distinct from the effect of 2B* on plaque size, as a virus in which 2B* was similarly truncated exhibited near-wildtype plaque size, thus indicating that 2B* also harbours additional functions. This work provides the first identification of a role of 2B* in innate immune antagonism and expands our knowledge of the protein complement of this important model virus. IMPORTANCEEncephalomyocarditis virus (EMCV) infects a range of species, causing economically important reproductive disorders in pigs and encephalitis and myocarditis in rodents. Due to its wide host range, it is an important model pathogen for investigating virus-host interactions. EMCV expresses an accessory protein, 2B*, from an overlapping open reading frame via an unusual ribosomal frameshifting mechanism. Although the frameshifting mechanism has been established, the function of the 2B* protein had not previously been explored. Here, we determined the host proteins to which 2B* binds and found that it specifically binds to the entire 14-3-3 protein family which, among other roles, contribute to the innate immune response to viral infection in mammalian cells. This interaction requires a specific stretch of amino acids at the end of 2B*. By interacting with the 14-3-3 proteins, 2B* blocks immune response activation. Thus, 2B* is a novel antagonist of innate immunity.

microbiology↗

Quantitative Label-Free Single-Cell Proteomics on the Orbitrap Astral MS

Single-cell proteomics by mass spectrometry (scp-MS) holds the potential to provide unprecedented insights into molecular features directly linked to the cellular phenotype, while deconvoluting complex organisms into their basic building blocks. Tailored sample preparation that maximizes the extracted amount of material that is introduced into the mass spectrometer has rapidly propelled the field forward. However, the measured signal is still at the lower edge of detection approaching the sensitivity boundary of current instrumentation. Here, we investigate the capacity of the enhanced sensitivity of the Orbitrap Astral mass spectrometer to facilitate deeper proteome profiles from low-input to single-cell samples. We carry out a comprehensive data acquisition method survey to pinpoint which parameters provide most sensitivity. Furthermore, we explore the quantitative accuracy of the obtained measurements to ensure that the obtained abundances are in line with expected ground truth values. We culminate our technical exploration by generating small datasets from two cultured cell lines and a primary bone marrow sample, to showcase obtainable proteome coverage differences from different source materials. Finally, as a proof of concept we explore protein covariation to showcase how information on known protein complexes is captured inherently in our scp-MS data.

biochemistry↗

One-Hour Phosphoproteome Analysis with the Orbitrap Astral Mass Spectrometer

Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. The technology was benchmarked to other state-of-the-art MS platforms using both synthetic peptide standards and with EGF-stimulated HeLa cells. We applied this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detected 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence, structural, and kinase specificity context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of novel phosphorylation events relevant to mitochondrial and brain biology.

systems biology↗

De novo lipogenesis pathway is a vulnerability in IDH1 mutant glioma

Histone deacetylases (HDACs) have a wide range of targets and can rewire both the chromatin and lipidome of cancer cells. In this study, we show that valproic acid (VPA), a brain penetrant anti-epileptic and histone deacetylase inhibitor, inhibits the growth of IDH1 mutant tumors in vivo and in vitro, with at least some selectivity over IDH1 wild type tumors. Surprisingly, genes upregulated by VPA showed no change in chromatin accessibility at the promoter, but there was a correlation between VPA downregulated genes and diminished promoter chromatin accessibility. VPA inhibited the transcription of lipogenic genes and these lipogenic genes showed significant decrease in promoter chromatin accessibility only in the IDH1 MT glioma cell lines tested. VPA targeted a key lipogenic gene, fatty acid synthase (FASN), via inhibition of the mTOR pathway and both VPA and a selective FASN inhibitor TVB-2640 rewired the lipidome and promoted apoptosis in an IDH1 MT but not in an IDH1 WT glioma cell line. We further find HDACs are involved in the regulation of lipogenic genes and in particular HDAC6 is important for regulation of FASN in IDH1 MT glioma. Finally, we show that FASN knockdown alone and VPA in combination with FASN knockdown significantly improved the survival of mice in a IDH1 MT primary orthotopic xenograft model in vivo. We conclude that targeting fatty acid metabolism through HDAC inhibition and/or FASN inhibition may be a novel therapeutic option in IDH1 mutant gliomas.

cancer biology↗

Evaluating the capabilities of the Astral mass analyzer for single-cell proteomics

The complexity of human physiology arises from well-orchestrated interactions between trillions of single cells in the body. While single-cell RNA sequencing (scRNA-seq) has enhanced our understanding of cell diversity, gene expression alone does not fully characterize cell phenotypes. Additional molecular dimensions, such as proteins, are needed to define cellular states accurately. Mass spectrometry (MS)-based proteomics has emerged as a powerful tool for comprehensive protein analysis, including single-cell applications. However, challenges remain in terms of throughput and proteomic depth, in order to maximize the biological impact of single-cell proteomics by Mass Spectrometry (scp-MS) workflows. This study leverages a novel high-resolution, accurate mass (HRAM) instrument platform, consisting of both an Orbitrap and an innovative HRAM Asymmetric Track Lossless (Astral) analyzer. The Astral analyzer offers high sensitivity and resolution through lossless ion transfer and a unique flight track design. We evaluate the performance of the Thermo Scientific Orbitrap Astral MS using Data-Independent Acquisition (DIA) and assess proteome depth and quantitative precision for ultra-low input samples. Optimal DIA method parameters for single-cell proteomics are identified, and we demonstrate the ability of the instrument to study cell cycle dynamics in Human Embryonic Kidney (HEK293) cells, and cancer cell heterogeneity in a primary Acute Myeloid Leukemia (AML) culture model.

systems biology↗

Narrow-window DIA: Ultra-fast quantitative analysis of comprehensive proteomes with high sequencing depth

Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here, we present an ultra-fast scanning data-independent acquisition (DIA) strategy consisting on 2-Th precursor isolation windows, dissolving the differences between data-dependent and independent methods. This is achieved by pairing a Quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer that provides >200 Hz MS/MS scanning speed, high resolving power and sensitivity, as well as low ppm-mass accuracy. Narrow-window DIA enables profiling of up to 100 full yeast proteomes per day, or [~]10,000 human proteins in half-an-hour. Moreover, multi-shot acquisition of fractionated samples allows comprehensive coverage of human proteomes in [~]3h, showing comparable depth to next-generation RNA sequencing and with 10x higher throughput compared to current state-of-the-art MS. High quantitative precision and accuracy is demonstrated with high peptide coverage in a 3-species proteome mixture, quantifying 14,000+ proteins in a single run in half-an-hour. TeaserAccurate and precise label-free quantification with comprehensive proteome coverage using narrow-window DIA

systems biology↗

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.

The growing trend towards high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time, and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass resolving quadrupole, the Orbitrap and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared to state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with high dynamic range and resolution, synchronized with Astral analyzers acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=100 SRC="FIGDIR/small/543408v1_ufig1.gif" ALT="Figure 1"> View larger version (35K): org.highwire.dtl.DTLVardef@1eedfdeorg.highwire.dtl.DTLVardef@1ab7939org.highwire.dtl.DTLVardef@a3b2f8org.highwire.dtl.DTLVardef@13ac46b_HPS_FORMAT_FIGEXP M_FIG C_FIG

cell biology↗

Evaluating the performance of the Astral mass analyzer for quantitative proteomics using data independent acquisition

We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high quality quantitative measurements across a wide dynamic range. We also use a newly developed extra-cellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5,000 plasma proteins in a 60-minute gradient with the Orbitrap Astral mass spectrometer.

biochemistry↗

The SARS-CoV-2 protein ORF3c is a mitochondrial modulator of innate immunity

The SARS-CoV-2 genome encodes a multitude of accessory proteins. Using comparative genomic approaches, an additional accessory protein, ORF3c, has been predicted to be encoded within the ORF3a sgmRNA. Expression of ORF3c during infection has been confirmed independently by ribosome profiling. Despite ORF3c also being present in the 2002-2003 SARS-CoV, its function has remained unexplored. Here we show that ORF3c localises to mitochondria during infection, where it inhibits innate immunity by restricting IFN-{beta} production, but not NF-{kappa}B activation or JAK-STAT signalling downstream of type I IFN stimulation. We find that ORF3c acts after stimulation with cytoplasmic RNA helicases RIG-I or MDA5 or adaptor protein MAVS, but not after TRIF, TBK1 or phospho-IRF3 stimulation. ORF3c co-immunoprecipitates with the antiviral proteins MAVS and PGAM5 and induces MAVS cleavage by caspase-3. Together, these data provide insight into an uncharacterised mechanism of innate immune evasion by this important human pathogen.

microbiology↗