Search bioRxivSearch

Biology subjects

Stenroos, M.

Publications and source records attributed to Stenroos, M..

2 recordsLinked to original sources

Locating highly correlated sources from MEG with (recursive) (R)DS-MUSIC

We introduce a source localization method of the MUltiple Signal Classification (MUSIC) family that can locate brain-signal sources robustly and reliably, irrespective of their temporal correlations. The method, double-scanning (DS) MUSIC, is based on projecting out the topographies of source candidates during topographical scanning in a way that breaks the mutual dependence of highly correlated sources, but keeps the uncorrelated sources intact. We also provide a recursive version of DS-MUSIC (RDS-MUSIC), which overcomes the peak detection problem present in the non-recursive methods. We compare DS-MUSIC and RDS-MUSIC with other localization techniques in numerous simulations with varying source configurations, correlations, and signal-to-noise ratios. DS- and RDS-MUSIC were the most robust localization methods; they had a high success rate and localization accuracy for both uncorrelated and highly correlated sources. In addition, we validated RDS-MUSIC by showing that it successfully locates bilateral synchronous activity from measured auditory-evoked MEG.

neuroscience

Requirements for coregistration accuracy in on-scalp MEG

Recent advances in magnetic sensing has made on-scalp magnetoencephalography (MEG) possible. In particular, optically-pumped magnetometers (OPMs) have reached sensitivity levels that enable their use in MEG. In contrast to the SQUID sensors used in current MEG systems, OPMs do not require cryogenic cooling and can thus be placed within millimetres from the head, enabling the construction of sensor arrays that conform to the shape of an individuals head. To properly estimate the location of neural sources within the brain, one must accurately know the position and orientation of sensors in relation to the head. With the adaptable on-scalp MEG sensor arrays, this coregistration becomes more challenging than in current SQUID-based MEG systems that use rigid sensor arrays.\n\nHere, we used simulations to quantify how accurately one needs to know the position and orientation of sensors in an on-scalp MEG system. The effects that different types of localisation errors have on forward modelling and source estimates obtained by minimum-norm estimation, dipole fitting, and beamforming are detailed.\n\nWe found that sensor position errors generally have a larger effect than orientation errors and that these errors affect the localisation accuracy of superficial sources the most. To obtain similar or higher accuracy than with current SQUID-based MEG systems, RMS sensor position and orientation errors should be < 4 mm and < 10{degrees}, respectively.

neuroscience