Search bioRxivSearch

Biology subjects

Stallinga, S.

Publications and source records attributed to Stallinga, S..

3 recordsLinked to original sources

Photon count estimation in single-molecule localization microscopy

Recently, Franke, Sauer and van de Linde1 introduced a way to estimate the axial position of single-molecules (TRABI). To this end, they compared the detected photon count from a temporal radial-aperture-based intensity estimation to the estimated count from Gaussian point-spread function (PSF) fitting to the data. Empirically they found this photometric ratio to be around 0.7-0.8 close to focus and decreasing away from it. Here, we explain this reported but unexplained discrepancy and furthermore show that the photometric ratio as indicator for axial position is susceptible even to typical optical aberrations.

molecular biology

High precision wavefront control in Point Spread Function engineering for single emitter localization

Point spread function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as well. Advanced PSF models such as spline fits to experimental PSFs or the vectorial PSF model can be used in the corresponding localization algorithms in order to model the intricate spot shape and deformations correctly. The complexity of the optical architecture and fit model makes PSF engineering approaches particularly sensitive to optical aberrations. Here, we present a calibration and alignment protocol for fluorescence microscopes equipped with a spatial light modulator (SLM) with the goal of establishing a wavefront error well below the diffraction limit for optimum application of complex engineered PSFs. We achieve high-precision wavefront control, to a level below 20 m{lambda} wavefront aberration over a 30 minute time window after the calibration procedure, using a separate light path for calibrating the pixel-to-pixel variations of the SLM, and alignment of the SLM with respect to the optical axis and Fourier plane within 3 {micro}m (x/y) and 100 {micro}m (z) error. Aberrations are retrieved from a fit of the vectorial PSF model to a bead z-stack and compensated with a residual wavefront error comparable to the error of the SLM calibration step. This well-calibrated and corrected setup makes it possible to create complex 3D+{lambda} PSFs that fit very well to the vectorial PSF model. Proof-of-principle bead experiments show precisions below 10 nm in x, y, and{lambda} , and below 20 nm in z over an axial range of 1 {micro}m with 2000 signal photons and 12 background photons.

biophysics

Fluorescence polarization control for on-off switching of single molecules at cryogenic temperatures

Light microscopy allowing sub-diffraction limited resolution has been among the fastest developing techniques at the interface of biology, chemistry and physics. Intriguingly no theoretical limit exists on how far the underlying measurement uncertainty can be lowered. In particular data fusion of large amounts of images can reduce the measurement error to match the resolution of structural methods like cryo-electron microscopy. Fluorescence, although reliant on a reporter molecule and therefore not the first choice to obtain ultra resolution structures, brings highly specific labeling of molecules in a large assemble to the table and inherently allows the detection of multiple colors, which enable the interrogation of multiple molecular species at the same time in the same sample. Here we discuss the problems to be solved in the coming years to aim for higher resolution and describe what polarization depletion of fluorescence at cryogenic temperatures can contribute for fluorescence imaging of biological samples like whole cells.

biophysics