Search bioRxiv⌕ Search

Biology subjects

Srinivasan, U. S.

Publications and source records attributed to Srinivasan, U. S..

2 recordsLinked to original sources

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗

Targeted measurement of blood flow in the Anterior Cerebral Artery using Diffuse Correlation Spectroscopy

SignificanceDiffuse Correlation Spectroscopy (DCS) is an established technique for non-invasive monitoring of Cerebral Blood Flow (CBF), but existing applications primarily measure CBF changes averaged over cortical tissue volumes. A method capable of targeting blood flow within a particular intracranial artery would expand the utility of DCS for vessel-specific cerebral perfusion monitoring and continuous bedside assessment. AimWe aim to investigate the feasibility of targeted, non-invasive monitoring of blood flow in the Anterior Cerebral Artery (ACA) using DCS through optimization of probe geometry and placement. ApproachA custom-built DCS system operating at 785 nm was used to probe ACA from the glabellar region. Source-detector (SD) separation, probe orientation, and probe location were systematically optimized using lower-limb motor tasks and a mental arithmetic task. The optimized configuration was evaluated using an ACA-mimicking multilayer phantom and validated in forty healthy volunteers during lower-limb activation tasks and postural changes. ResultsAn SD separation of 17 mm, vertical probe orientation, and glabellar placement provided the highest sensitivity to ACA-related blood flow changes. Phantom experiments demonstrated sensitivity to flow changes in a vessel located 45 mm beneath the scalp and showed that the frontal sinus, cerebrospinal fluid, and the absence of cortical tissue beneath the glabella along the longitudinal fissure together provide the best optical window for probing deep ACA flow. Using the optimized probe configuration, significant increases in relative CBF were observed during standing leg marching (66.4 {+/-} 38.6%) and supine leg crunches (39.4 {+/-} 32.2%) (p < 0.01), with consistent responses during supine-to-stand postural transitions. ConclusionThe proposed DCS approach enables targeted measurement of blood flow within the ACA territory. This technique provides a framework for continuous, non-invasive monitoring of ACA perfusion and has potential applications in cerebrovascular monitoring and stroke care.

bioengineering↗