Search bioRxiv⌕ Search

Biology subjects

Sohrabpour, A.

Publications and source records attributed to Sohrabpour, A..

5 recordsLinked to original sources

Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG

Abstract Optically pumped magnetometer (OPM) sensors can be placed closer to the scalp than conventional superconducting quantum interference devices (SQUID), resulting in larger magnetoencephalography (MEG) signals from neuronal activity. For event-related sensor data, such as epileptogenic activity or sensory and motor evoked responses, however, OPMs and SQUIDs often differ less in signal-to-noise ratio (SNR) than in signal magnitude. We examined two factors contributing to the relative SNR: the dependence of the signal magnitude on source depth and the effect of scalp-to-sensor distance on the noise level. Simulated MEG data for a current dipole in a spherical head model confirmed that on-scalp sensor placement delivers the largest SNR gain for superficial sources. Depending on the relative overall noise level, there may be a crossover source depth at which SNR is equal for on-scalp and off-scalp sensors and beyond which off-scalp sensors achieve higher SNR. Analysis of the equal-SNR source depth in different-sized spherical head models indicated that, for a given relative noise level, the proportion of the brain where SNR is higher in OPM than in SQUID was larger in small head models, supporting the benefits of OPMs in pediatric studies. To experimentally evaluate noise contributions of brain and non-brain origin to the SNR, we recorded somatosensory evoked fields (SEFs) at varying scalp-to-sensor distances. Generally, both the evoked response magnitude and the noise level were lower when the sensors were further away from the scalp; consequently, the SNR depended less than the signal magnitude on the scalp-to-sensor distance. Comparison of power spectral densities (PSDs) at different sensor-to-scalp distances allowed us to identify whether the dominant noise source was of brain or non-brain origin at different frequency bands. Overall, the results highlight complementary properties of OPMs vs. SQUIDs in terms of SNR, which is of interest when optimizing MEG experiments for specific subject populations and brain regions.

neuroscience↗

Quantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling

ObjectiveThe cerebellum is increasingly recognized as a key component of large-scale brain networks implicated in epilepsy, yet its electrophysiological characterization remains limited in noninvasive recordings. This limitation arises from the cerebellums depth, complex folding, and unfavorable source orientations, which challenge conventional magnetoencephalography (MEG) and electroencephalography (EEG). Here, we quantitatively characterize cerebellar signal detectability across modalities and sensor configurations using anatomically informed source modeling at the population level. MethodsWe analyzed clinical MEG and EEG recordings from a large cohort of patients with epilepsy undergoing presurgical evaluation. Cerebellar and cerebral source spaces were constructed using subject-specific anatomical models derived from routine clinical MRI, enabling consistent forward modeling across individuals. Signal-to-noise ratio (SNR) was estimated at individual source locations and summarized at the regional level. In addition to clinical Superconducting quantum interference device (SQUID)-MEG and EEG, multiple on-scalp optically pumped magnetometer (OPM) configurations were evaluated through simulation, including layouts matched to clinical sensor geometries and layouts optimized for posterior fossa coverage. The effects of source orientation, sensor-source distance, and head size on SNR were systematically investigated. ResultsIn routine clinical recordings, cerebellar SNR was consistently lower than superficial cortical reference levels, confirming the limited detectability of cerebellar activity with standard SQUID-MEG and EEG. Reducing sensor-source distance by placing OPMs at SQUID-equivalent locations, i.e., projecting SQUID sensor locations to the scalp, did not improve cerebellar SNR, indicating that proximity alone is insufficient for better detectability of deeper sources. In contrast, cerebellar-optimized OPM layouts produced substantial SNR gains in posterior cerebellar regions. The effects of source orientation influence SNR differences between OPM and EEG (under identical sensor/electrode coverage) but were secondary to depth- and geometry-related constraints. Mediation analysis further demonstrated that relative sensor distance significantly mediated OPM-related advantages in posterior cerebellar regions, particularly in individuals with smaller head sizes. ConclusionsThese findings demonstrate that cerebellar signal detectability is governed primarily by anatomical depth and geometry rather than sensor proximity alone. Anatomically informed source modeling, combined with flexible and region-specific sensor layouts, enables meaningful improvements in cerebellar SNR that are not achievable with fixed-helmet systems. While directly motivated by epilepsy, this framework advances human brain mapping beyond the cerebrum by providing a principled approach for evaluating MEG and EEG sensitivity in deep and highly folded brain structures.

bioengineering↗

Biplanar nulling coil system for OPM-MEG using printed circuit boards

Optically pumped magnetometers (OPMs) are a promising sensor technology for non-invasive measurement of human electrophysiological signals, in particular the magnetoencephalogram (MEG). OPMs do not need cryogenic cooling and can be placed conformal to the subjects scalp, thus greatly reducing the sensor-to-source distance and improving signal sensitivity. OPMs, however, require near-zero background magnetic field to achieve linearity and minimize signal distortion. Prior work has proposed the use of biplanar field nulling coils to remove the uniform and gradient components of the background magnetic field. Biplanar coils have been expensive to construct, involving tedious error-prone manual winding of over 1000 m of copper wire. In this work, we designed and fabricated background field nulling coils (three uniform and three gradient components) on two-layer Printed Circuit Boards (PCBs). We used an open-source software (bfieldtools) to determine the current loops needed to produce the target magnetic field in a 50-cm-diameter spherical volume. We developed a software-based approach to connect the discrete current loops into a continuous conducting path traversing the two layers of the PCB. For ease of manufacture, the designed (1.5 x 1.5 m2) coils were cut along the symmetry axis and printed as pairs of 1.5 x 0.75 m2 PCBs (2 oz Cu), soldered together and mounted on a sliding aluminum frame. The efficiency of the coils (1.3 - 7.1 nT/mA) was similar or higher than previously reported in the literature. We mapped the field inside the target region after field nulling inside our single-layer shielded room and were able to reduce the largest component of the background field from 21 to 2 nT. Using our nulling coil system, we were able to operate OPMs in a lightly shielded room (background field varying from 6.5 to 108 nT in the floor-to-ceiling direction) to record somatosensory evoked fields (SEFs) comparable to those measured using SQUID-based MEG in a 3-layer shielded room. We disseminate the software and hardware as an open-source package opmcoils. This work will facilitate access to more affordable field nulling coils for OPM-MEG and help to realize the potential of OPM-MEG as an accessible sensor technology for use in human neuroscience.

neuroscience↗

Imaging the Extent and Location of Spatiotemporally Distributed Epileptiform Sources from MEG Measurements

Non-invasive MEG/EEG source imaging provides valuable information about the epileptogenic brain areas which can be used to aid presurgical planning in focal epilepsy patients suffering from drug-resistant seizures. However, the source extent estimation for electrophysiological source imaging remains to be a challenge and is usually largely dependent on subjective choice. Our recently developed algorithm, fast spatiotemporal iteratively reweighted edge sparsity minimization (FAST-IRES) strategy, has been shown to objectively estimate extended sources from EEG recording, while it has not been applied to MEG recordings. In this work, through extensive numerical experiments and real data analysis in a group of focal drug-resistant epilepsy patients interictal spikes, we demonstrated the ability of FAST-IRES algorithm to image the location and extent of underlying epilepsy sources from MEG measurements. Our results indicate the merits of FAST-IRES in imaging the location and extent of epilepsy sources for pre-surgical evaluation from MEG measurements.

bioengineering↗

SIFNet: Electromagnetic Source Imaging Framework Using Deep Neural Networks

Electroencephalography (EEG) and magnetoencephalography (MEG) are used to measure brain activity, noninvasively, and are useful tools for brain research and clinical management of brain disorders. Tremendous effort has been made in solving the inverse source imaging problem from EEG/MEG measurements. This is a challenging ill-posed problem, since the number of measurements is much smaller than the number of possible sources in the brain. Various methods have been developed to estimate underlying brain sources from noninvasive EEG/MEG as this can offer insight about the underlying brain electrical activity with significantly improved spatial resolution. In this work, we propose a novel data-driven Source Imaging Framework using deep learning neural networks (SIFNet), where (1) a simulation pipeline is designed to model realistic brain activation and EEG/MEG signals to train generalizable neural networks, (2) and a residual convolutional neural network is trained using the simulated data, capable of estimating source distributions from EEG/MEG recordings. The performance of our proposed SIFNet approach is evaluated in a series of computer simulations, which indicates the excellent performance of SIFNet outperforming conventional weighted minimum norm algorithms that were tested in this work. The SIFNet is further tested by analyzing interictal EEG data recorded in a clinical setting from a focal epilepsy patient. The results of this clinical data analysis indicate accurate localization of epileptogenic activity as validated by the epileptogenic zone clinically determined in this patient. In sum, the proposed SIFNet approach promises to offer an alternative solution to the EEG/MEG inverse source imaging problem, shows promising signs of being robust against measurement noise, and is easy to implement, therefore, being translatable to clinical practice.

bioengineering↗