Search bioRxiv⌕ Search

Biology subjects

Sim, S. R.

Publications and source records attributed to Sim, S. R..

2 recordsLinked to original sources

Vision Transformers as a Framework for Imaging Fluorescence Correlation Spectroscopy

Fluorescence correlation spectroscopy (FCS) is widely used for quantifying molecular dynamics in live cells. However, conventional FCS relies on the autocorrelation function (ACF), a lossy transformation that discards higher-order information, mathematically couples distinct biophysical parameters, and requires long measurements (~50,000 frames, or ~1 minute) that obscure short-lived transient events. To overcome this information bottleneck, we introduce ImFCSViT, a spatiotemporal Vision Transformer-based framework that bypasses the ACF representation entirely, operating directly on raw fluorescence image stacks. By introducing a dedicated normalization token to preserve global intensity statistics, our approach simultaneously extracts four biophysical parameters (diffusion coefficient D, particle density N, particle brightness B, and PSF structure factor {sigma}0) in a single forward pass. Requiring only 2.5 s of data, and potentially down to 1 s (a 1-2 order reduction in data requirement), our approach accurately recovers diffusion coefficients while utilizing its spatial field-of-view to reveal spatially heterogeneous, slow-diffusing sub-populations in lipid bilayers and live-cell plasma membranes that are invisible to classical FCS. By leveraging the data-driven representational learning capabilities of deep learning, we present a flexible, generalizable, and powerful tool for mapping complex, multi-parameter spatiotemporal dynamics in biological systems.

biophysics↗

Deep learning reduces data requirements and allows real-time measurements in Imaging Fluorescence Correlation Spectroscopy

Imaging Fluorescence Correlation Spectroscopy (Imaging FCS) is a powerful tool to extract information on molecular mobilities, actions and interactions in live cells, tissues and organisms. Nevertheless, several limitations restrict its applicability. First, FCS is data hungry, requiring 50,000 frames at 1 ms time resolution to obtain accurate parameter estimates. Second, the data size makes evaluation slow. Thirdly, as FCS evaluation is model-dependent, data evaluation is significantly slowed unless analytic models are available. Here we introduce two convolutional neural networks (CNNs) - FCSNet and Im-FCSNet - for correlation and intensity trace analysis, respectively. FCSNet robustly predicts parameters in 2D and 3D live samples. ImFCSNet reduces the amount of data required for accurate parameter retrieval by at least one order of magnitude and makes correct estimates even in moderately defocused samples. Both CNNs are trained on simulated data, are model-agnostic, and allow autonomous, real-time evaluation of Imaging FCS measurements.

biophysics↗