Search bioRxiv⌕ Search

Biology subjects

Sigal, I. A.

Publications and source records attributed to Sigal, I. A..

4 recordsLinked to original sources

Lamina cribrosa vessel and collagen beam networks are distinct

Our goal was to analyze the spatial interrelation between vascular and collagen networks in the lamina cribrosa (LC). Specifically, we quantified the percentages of collagen beams with/without vessels and of vessels inside/outside of collagen beams. To do this, the vasculature of six normal monkey eyes was labelled by perfusion post-mortem. After enucleation, coronal cryosections through the LC were imaged using fluorescence and polarized light microscopy to visualize the blood vessels and collagen beams, respectively. The images were registered to form 3D volumes. Beams and vessels were segmented, and their spatial interrelationship was quantified in 3D. We found that 22% of the beams contained a vessel (range 14% to 32%), and 21% of vessels were outside beams (13% to 36%). Stated differently, 78% of beams did not contain a vessel (68% to 86%), and 79% of vessels were inside a beam (64% to 87%). Individual monkeys differed significantly in the fraction of vessels outside beams (p<0.01 by linear mixed effect analysis), but not in the fraction of beams with vessels (p>0.05). There were no significant differences between contralateral eyes in the percent of beams with vessels and of vessels outside beams (p>0.05). Our results show that the vascular and collagenous networks of the LC in monkey are clearly distinct, and the historical notions that each LC beam contains a vessel and all vessels are within beams are inaccurate. We postulate that vessels outside beams may be relatively more vulnerable to mechanical compression by elevated IOP than are vessels shielded inside of beams. Research highlights- We combined fluorescence and polarized light microscopy to map in 3D the lamina cribrosa vessels and collagen beams of three pairs of monkey eyes - Collagen beam and vessel networks of the lamina cribrosa have distinct topologies - Over half of lamina cribrosa collagen beams did not contain a blood vessel - One fifth of blood vessels in the lamina cribrosa were outside collagen beams - Beams with/without vessels and vessels inside/outside beams may respond differently to IOP

bioengineering↗

Real-time imaging of optic nerve head collagen microstructure and biomechanics using instant polarized light microscopy

Current tools lack the temporal or spatial resolution necessary to image many important aspects of the architecture and dynamics of the optic nerve head (ONH). We evaluated the potential of instant polarized light microscopy (IPOL) to overcome these limitations by leveraging the ability to capture collagen fiber orientation and density in a single image. Coronal sections through the ONH of fresh normal sheep eyes were imaged using IPOL while they were stretched using custom uniaxial or biaxial micro-stretch devices. IPOL allows identifying ONH collagen architectural details, such as fiber interweaving and crimp, and has high temporal resolution, limited only by the frame rate of the camera. Local collagen fiber orientations and deformations were quantified using color analysis and image tracking techniques. We quantified stretch-induced collagen uncrimping of lamina cribrosa (LC) and peripapillary sclera (PPS), and changes in LC pore size (area) and shape (convexity and aspect ratio). The simultaneous high spatial and temporal resolutions of IPOL revealed complex ONH biomechanics: i) stretch-induced local deformation of the PPS was nonlinear and nonaffine. ii) under load the crimped collagen fibers in the PPS and LC straightened, without torsion and with only small rotations. iii) stretch-induced LC pore deformation was anisotropic and heterogeneous among pores. Overall, with stretch the pores were became larger, more convex, and more circular. We have demonstrated that IPOL reveals details of collagen morphology and mechanics under dynamic loading previously out of reach. IPOL can detect stretch-induced collagen uncrimping and other elements of the tissue nonlinear mechanical behavior. IPOL showed changes in pore morphology and collagen architecture that will help improve understanding of how LC tissue responds to load. HighlightsO_LIWe demonstrate that instant polarized light microscopy allows visualization and quantification of changes in optic nerve head collagen morphology and architecture under dynamic loading C_LIO_LIWe show crimped collagen fibers in the peripapillary sclera and lamina cribrosa straightening under load, without torsion and with only small rotations. C_LIO_LIWe show that stretch-induced local deformation of the peripapillary sclera was nonlinear and nonaffine. C_LIO_LIWe show that stretch-induced lamina cribrosa pore deformation was anisotropic and heterogeneous among pores. C_LIO_LIOur results show this novel imaging technique could help understand the role of collagen microstructure in eye physiology, aging, and in biomechanics-related diseases, such as glaucoma and myopia. C_LI

bioengineering↗

A high-accuracy and high-efficiency digital volume correlation method to characterize in-vivo optic nerve head biomechanics from optical coherence tomography

In-vivo optic nerve head (ONH) biomechanics characterization is emerging as a promising way to study eye physiology and pathology. We propose a high-accuracy and high-efficiency digital volume correlation (DVC) method for the purpose of characterizing the in-vivo ONH deformation from volumes acquired by optical coherence tomography (OCT). Using a combination of synthetic tests and analysis of OCTs from monkey ONHs subjected to acute and chronically elevated intraocular pressure, we demonstrate that our proposed methodology overcomes several challenges for conventional DVC methods. First, it accounts for large ONH rigid body motion in the OCT volumes which could otherwise lead to analysis failure; second, sub-voxel-accuracy displacement can be guaranteed despite high noise and low image contrast of some OCT volumes; third, computational efficiency is greatly improved, such that the memory consumption of our method is substantially lower than with conventional methods; fourth, we introduce a parameter measuring displacements confidence. Test of image noise effects showed that the proposed DVC method had displacement errors smaller than 0.028 voxels with speckle noise and smaller than 0.037 voxels with Gaussian noise; The absolute (relative) strain errors in the three directions were lower than 0.0018 (4%) with speckle noise and than 0.0045 (8%) with Gaussian noise. Compared with conventional DVC methods, the proposed DVC method had substantially improved overall displacement and strain errors under large body motions (lower by up to 70%), with 75% lower computation times, while saving about 30% memory. The study thus demonstrates the potential of the proposed technique to investigate ONH biomechanics.

bioengineering↗

Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo

Intracranial pressure (ICP) has been proposed to play an important role in the sensitivity to intraocular pressure (IOP) and susceptibility to glaucoma. However, the in vivo effects of simultaneous, controlled, acute variations in ICP and IOP have not been directly measured. We quantified the deformations of the anterior lamina cribrosa (ALC) and scleral canal at Bruchs membrane opening (BMO) under acute elevation of IOP and/or ICP. Four eyes of three monkeys were imaged in vivo with OCT under four pressure conditions: IOP and ICP either at baseline or elevated. The BMO and ALC were reconstructed from manual delineations. From these, we determined canal area at the BMO (BMO area), BMO aspect ratio and planarity, and ALC median depth relative to the BMO plane. To better account for the pressure effects on the imaging, we also measured ALC visibility as a percent of the BMO area. Further, ALC depths were analyzed only in regions where the ALC was visible in all pressure conditions. Bootstrap sampling was used to obtain mean estimates and confidence intervals, which were then used to test for significant effects of IOP and ICP, independently and in interaction. Response to pressure manipulation was highly individualized between eyes, with significant changes detected in a majority of the parameters. Significant interactions between ICP and IOP occurred in all measures, except ALC visibility. On average, ICP elevation expanded BMO area by 0.17mm2 at baseline IOP, and contracted BMO area by 0.02 mm2 at high IOP. ICP elevation decreased ALC depth by 10m at baseline IOP, but increased depth by 7 m at high IOP. ALC visibility decreased as ICP increased, both at baseline (-10%) and high IOP (-17%). IOP elevation expanded BMO area by 0.04 mm2 at baseline ICP, and contracted BMO area by 0.09 mm2 at high ICP. On average, IOP elevation caused the ALC to displace 3.3 m anteriorly at baseline ICP, and 22 m posteriorly at high ICP. ALC visibility improved as IOP increased, both at baseline (5%) and high ICP (8%). In summary, changing IOP or ICP significantly deformed both the scleral canal and the lamina of the monkey ONH, regardless of the other pressure level. There were significant interactions between the effects of IOP and those of ICP on LC depth, BMO area, aspect ratio and planarity. On most eyes, elevating both pressures by the same amount did not cancel out the effects. Altogether our results show that ICP affects sensitivity to IOP, and thus that it can potentially also affect susceptibility to glaucoma. Research Highlights- In vivo ONH deformations caused by acute, controlled, simultaneous changes in IOP and/or ICP can be directly visualized and measured in the monkey eye using OCT. - Acute changes of either IOP or ICP significantly deformed both the scleral canal and the lamina cribrosa, regardless of the other pressure level. - Pressures interacted, meaning that the effects of one pressure depended significantly on the level of the other pressure. - Elevating both pressures did not cancel out the effects of one of them being elevated. - Our results show that ICP affects sensitivity to IOP, and thus that it can potentially also affect susceptibility to glaucoma.

bioengineering↗