Search bioRxiv⌕ Search

Biology subjects

Shehata, A. W.

Publications and source records attributed to Shehata, A. W..

4 recordsLinked to original sources

Myoelectric Prosthesis Control using Recurrent Convolutional Neural Network Regression Mitigates the Limb Position Effect

Although state-of-the-art myoelectric prostheses offer persons with upper limb amputation extensive movement capabilities, users have not been afforded a reliable means to control common movements required in daily living. Many proposed prosthesis controllers use pattern recognition, a method that learns and recognizes patterns of electromyographic (EMG) signals produced by the users residual limb muscles to predict and execute device movements. Such control becomes unreliable in high limb positions--a problem known as the limb position effect. Pattern recognition often uses a classification algorithm; simple to implement, but limits user-initiated control to only one device movement at a time, at a single speed. To combat position-related control deficiencies and classification controller constraints, we developed and tested two recurrent convolutional neural network (RCNN) pattern recognition-based solutions: (1) an RCNN classification controller that uses EMG plus positional inertial measurement unit (IMU) signals to offer one-speed, sequential movement control; and (2) an RCNN regression controller that uses the same data capture technique to offer simultaneous control of multiple movements and device movement velocity. We assessed both RCNN controllers by comparing them to a commonly used linear discriminant analysis classification controller (LDA-Baseline). Participants without upper limb impairment were recruited to perform multipositional tasks while wearing a simulated prosthesis. Both RCNN classification and regression controllers showed improved functional task performance over LDA-Baseline, in 11 and 38 out of 115 metrics, respectively. This work contributes an RCNN regression-based controller that provides accurate, simultaneous, and proportional movements to EMG-based technologies including prostheses, exoskeletons, and even muscle-activated video games.

bioengineering↗

A multifaceted suite of metrics for comparative myoelectric prosthesis controller research

Upper limb robotic (myoelectric) prostheses are technologically advanced, but challenging to use. In response, substantial research is being done to develop user-specific prosthesis controllers that can predict a persons intended movements. Most studies that test and compare new controllers rely on simple assessment measures such as task scores (e.g., number of objects moved across a barrier) or duration-based measures (e.g., overall task completion time). These assessment measures, however, fail to capture valuable details about: the quality of device arm movements; whether these movements match users intentions; the timing of specific wrist and hand control functions; and users opinions regarding overall device reliability and controller training requirements. In this work, we present a comprehensive and novel suite of myoelectric prosthesis control evaluation metrics that better facilitates analysis of device movement details--spanning measures of task performance, control characteristics, and user experience. As a case example of their use and research viability, we applied these metrics in real-time control experimentation. Here, eight participants without upper limb impairment compared device control offered by a deep learning-based controller (recurrent convolutional neural network-based classification with transfer learning, or RCNN-TL) to that of a commonly used controller (linear discriminant analysis, or LDA). The participants wore a simulated prosthesis and performed complex functional tasks across multiple limb positions. Analysis resulting from our suite of metrics identified 16 instances of a user-facing problem known as the "limb position effect". We determined that RCNN-TL performed the same as or significantly better than LDA in four such problem instances. We also confirmed that transfer learning can minimize user training burden. Overall, this study contributes a multifaceted new suite of control evaluation metrics, along with a guide to their application, for use in research and testing of myoelectric controllers today, and potentially for use in broader rehabilitation technologies of the future.

neuroscience↗

Myoelectric Prosthesis Control: Improving Internal Model Strength and Performance Using Augmented Feedback

Myoelectric prosthetic devices are commonly used to help upper limb amputees perform activities of daily living, however amputees still lack the sensory feedback required to facilitate reliable and precise control. Augmented feedback may play an important role in affecting both short-term performance, through real-time regulation, and long-term performance, through the development of stronger internal models. In this work, we investigate the potential tradeoff between controllers that enable better short-term performance and those that provide sufficient feedback to develop a strong internal model. We hypothesize that augmented feedback may be used to mitigate this tradeoff, ultimately improving both short and long-term control. We used psychometric measures to assess the internal model developed while using a filtered myoelectric controller with augmented audio feedback, imitating classification-based control but with augmented regression-based feedback. In addition, we evaluated the short-term performance using a multi degree-of-freedom constrained-time target acquisition task. Results obtained from 24 able-bodied subjects show that an augmented feedback control strategy using audio cues enables the development of a stronger internal model than the filtered control with filtered feedback, and significantly better path efficiency than both raw and filtered control strategies. These results suggest that the use of augmented feedback control strategies may improve both short-term and long-term performance.

bioengineering↗

Evaluating Internal Model Strength and Performance of Myoelectric Prosthesis Control Strategies

Ongoing developments in myoelectric prosthesis control have provided prosthesis users with an assortment of control strategies that vary in reliability and performance. Many studies have focused on improving performance by providing feedback to the user, but have overlooked the effect of this feedback on internal model development, which is key to improving long-term performance. In this work, the strength of internal models developed for two commonly used myoelectric control strategies: raw control with raw feedback (using a regression-based approach), and filtered control with filtered feedback (using a classifier-based approach), were evaluated using two psychometric measures: trial-by-trial adaptation and just-noticeable-difference. The performance of both strategies was also evaluated using a Schmidts style target acquisition task. Results obtained from 24 able-bodied subjects showed that although filtered control with filtered feedback had better short-term performance in path efficiency (p < 0.05), raw control with raw feedback resulted in stronger internal model development (p < 0.05), which may lead to better long-term performance. Despite inherent noise in the control signals of the regression controller, these findings suggest that rich feedback associated with regression control may be used to improve human understanding of the myoelectric control system.

bioengineering↗