Search bioRxiv⌕ Search

Biology subjects

Sesay, A. M.

Publications and source records attributed to Sesay, A. M..

4 recordsLinked to original sources

A platform for automated training of mammalian cell physiology

Controlling cell physiology is difficult, not only because of cells complexity, but also their capacity for real-time adaptation to interventions, leading to challenges such as drug resistance and transgene silencing. Accumulating evidence suggests that this adaptivity resembles classical forms of learning defined in behavioral science. However, a lack of appropriate platforms has led to gaps in our understanding of cells capacity for adaptive problem-solving in physiological and transcriptional space. Here, we present a device, the Cell Trainer, capable of performing a wide variety of automated training experiments on non-neural mammalian cells, using timed drug pulses as the stimulus, and a mobile fluorescence microscope to capture images of responses, across replicate cultures. The Cell Trainer can operate in either an open-loop (feedforward) or closed-loop (feedback-controlled) mode, and our image analysis pipeline can report the behaviors of individual cells throughout each experiment and quantify population heterogeneity. We showcase the ability of the Cell Trainer to execute experimental protocols and perform single-cell analyses in both modes. We first demonstrate with a feedforward experiment in which myoblasts are repeatedly pulsed with dimethyl sulfoxide (DMSO) and their discrete calcium responses are analyzed, revealing sensitization-like dynamics. Next, we demonstrate a feedback control scheme wherein the fluorescence of a pH/voltage reporter in kidney cells is maintained below a threshold level with controlled pulses of acid. To accelerate research in the field of cell training, learning, and memory, we are openly sharing the Cell Trainer schematics and software with the research community. This platform provides a flexible tool for studying how cellular physiological states can be shaped by patterned stimulation and feedback control through approaches that work with the native adaptive competencies of cells.

bioengineering↗

Organ Chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels

Despite remarkable advances in Organ-on-a-chip (Organ Chip) microfluidic culture technology, recreating tissue-relevant physiological conditions, such as the region-specific oxygen concentrations, remains a formidable technical challenge, and analysis of tissue functions is commonly carried out using one analytical technique at a time. Here, we describe two-channel Organ Chip microfluidic devices fabricated from polydimethylsiloxane and gas impermeable polycarbonate materials that are integrated with multiple sensors, mounted on a printed circuit board and operated using a commercially available Organ Chip culture instrument. The novelty of this system is that it enables the recreation of physiologically relevant tissue-tissue interfaces and oxygen tension as well as non-invasive continuous measurement of transepithelial electrical resistance, oxygen concentration and pH, combined with simultaneous analysis of cellular metabolic activity (ATP/ADP ratio), cell morphology, and tissue phenotype. We demonstrate the reliable and reproducible functionality of this system in living human Gut and Liver Chip cultures. Changes in tissue barrier function and oxygen tension along with their functional and metabolic responses to chemical stimuli (e.g., calcium chelation, oligomycin) were continuously and noninvasively monitored on-chip for up to 23 days. A physiologically relevant microaerobic microenvironment that supports co-culture of human intestinal cells with living Lactococcus lactis bacteria also was demonstrated in the Gut Chip. The integration of multi-functional sensors into Organ Chips provides a robust and scalable platform for the simultaneous, continuous, and non-invasive monitoring of multiple physiological functions that can significantly enhance the comprehensive and reliable evaluation of engineered tissues in Organ Chip models in basic research, preclinical modeling, and drug development.

bioengineering↗

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human endo- and ecto-cervix chips

Modulation of mucus production by the human endo- and ecto-cervical epithelium by steroid hormones and associated interactions with commensal microbiome play a central role in the physiology and pathophysiology of the female reproductive tract. However, most of our knowledge about these interactions is based on results from animal studies or in vitro models that fail to faithfully mimic the mucosal environment of the human cervix. Here we describe microfluidic organ-on-a-chip (Organ Chip) models of the human cervical mucosa that recreate the cervical epithelial-stromal interface with a functional epithelial barrier and produce abundant mucus that has compositional, biophysical, and hormone-responsive properties similar to the living cervix. Application of continuous fluid flow to chips lined with primary human cervical epithelial cells from a commercial source that contained a mixture of primary human ecto- and endo-cervical epithelial cells promoted preferential expression of the ecto-cervical phenotype, whereas use of periodic flow including periods of stasis induced endo-cervical specialization. When the periodic flow Cervix Chips were co-cultured with living Lactobacillus crispatus and Gardnerella vaginalis bacterial communities to respectively mimic the effects of human host interactions with optimal (healthy) or non-optimal (dysbiotic) microbiome associated with an ascending infection in the female reproductive tract, significant differences in tissue innate immune responses, barrier function, cell viability and protein profile, and mucus composition were detected reminiscent of those observed in vivo. Thus, these Organ Chip models of human cervix provide a physiologically relevant experimental in vitro model to study cervical mucus physiology and its role in human host-microbiome interactions as well as a potential preclinical testbed for development of therapeutic interventions to enhance womens health.

bioengineering↗

Establishment of physiologically relevant oxygen gradients in microfluidic organ chips

In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.

bioengineering↗