Search bioRxiv⌕ Search

Biology subjects

Seginer, A.

Publications and source records attributed to Seginer, A..

2 recordsLinked to original sources

Adaptive Magnetic Resonance

Nuclear magnetic resonance is one of the cornerstones of modern medicine and biomedical research. Over the past several decades, the speed and precision of in-vivo magnetic resonance imaging (MRI) and spectroscopy (MRS) have increased by leaps and bounds, by utilizing sophisticated excitation and acquisition techniques, from parallel imaging and compressed sensing to magnetic resonance fingerprinting. However, these approaches have all been static in nature, fixing measurement parameters in advance, in anticipation of a wide range of expected tissue parameter values, and are therefore sub-optimal for any given subject. We depart from the conventional framework of magnetic resonance and propose a new approach - termed adaptive magnetic resonance - which binds acquisition and excitation, by using the measured signal to update and fine-tune the measurement parameters in real time. This targets the specific tissue characteristics of the subject while they are being scanned. Adaptive magnetic resonance provides a completely new and previously-untapped avenue for improving the sensitivity and specificity of in-vivo magnetic resonance across all tissue contrast mechanisms. Equivalently, it can accelerate data acquisition compared to non-adaptive schemes, by obtaining the same precision using fewer, optimally tuned excitations. We demonstrate that an adaptive pulse sequence for measuring the transverse relaxation time (T2) of metabolites in-vivo improves upon the precision of static approaches by a factor of {approx} 1.7 - or, alternatively, accelerates acquisition 2.5-fold.

bioengineering↗

Reducing SAR in 7T brain fMRI by circumventing fat suppression while removing the lipid signal through a parallel acquisition approach

Ultra-high-field functional magnetic resonance imaging (fMRI) offers the way to new insights while increasing the spatial and temporal resolution. However, a crucial concern in 7T human MRI is the increase in power deposition, supervised through the specific absorption rate (SAR). The SAR limitation can restrict the brain coverage or the minimal repetition time of fMRI experiments. fMRI is based on the well-known gradient-echo echo-planar imaging (GRE-EPI) sequence, which offers ultrafast acquisition. Commonly, the GRE-EPI sequence comprises two pulses: fat suppression and excitation. This work provides the means for a significant reduction in the SAR by circumventing the fat-suppression pulse. Without this fat-suppression, however, lipid signal can result in artifacts due to the chemical shift between the lipid and water signals. Our approach exploits a reconstruction similar to the simultaneous-multi-slice (SMS) method to separate the lipid and water images, thus avoiding undesired lipid artifacts in brain images. The lipid-water separation is based on the known spatial shift of the lipid signal, which can be detected by the multi-channel coils sensitivity profiles. Our study shows robust human imaging, offering greater flexibility to reduce the SAR, shorten the repetition time or increase the volume coverage with substantial benefit for brain functional studies.

neuroscience↗