Search bioRxiv⌕ Search

Biology subjects

Seetharam, S.

Publications and source records attributed to Seetharam, S..

2 recordsLinked to original sources

Tricuspid Valve Chordae Tendineae: Where are They, How Many are There, and What are Their Properties?

Background: Tricuspid chordae play an important role in valve function. Unfortunately, they are poorly visible in clinical imaging and their mechanical properties cannot be measured noninvasively. This lack of data on chordal structure and properties limits our understanding of the tricuspid valve in general and efforts to model the valve in particular. Objectives: Our primary objective was to quantify chordal insertion patterns, structure, and mechanical properties. Our secondary objective was to test whether chordal structure and properties differed between control hearts and hearts with heart failure. Methods: We mapped chordal insertions in 25 excised human valves, measured the cross-sectional areas of 281 specimens, and conducted uniaxial tensile tests on 265 specimens from 12 of the 25 valves (eight control and four heart failure). We used mixed-effects models to assess the influence of heart failure and anatomical position. Finally, we used a hierarchical Bayesian model to represent area-dependent Ogden material parameters. Results: We found that chordal insertion density was highest at the free edge (p < 0.001), and lowest in the anterior leaflet (p < 0.001). Median cross-sectional area was 0.223 mm2, with anterior chordae the largest (p < 0.001) and septal the smallest (p < 0.001). A 10% increase in cross-sectional area was associated with 5.3% and 3.3% decreases in toe and calf stiffness, respectively. Heart failure was not associated with larger areas or higher stiffness. Conclusions: Human chordal geometry and material behavior varied with location and size. These openly shared data support assigning chordal insertions, sizes, and material properties in tricuspid valve models.

physiology↗

No Strings Attached: Predicting Tricuspid Valve Deformation Without In Vivo Chordal Geometry

Predictive biomechanical models of the tricuspid valve require accurate representation of the chordae tendineae, yet subject-specific chordal geometry is difficult to reconstruct from non-invasive imaging. Here, we adopt a framework for generating functionally equivalent synthetic chordae without prior knowledge of in vivo chordal attachments. To this end, we first adapt an anatomy-informed hyperelastic shape-matching method that establishes correspondence between end-diastolic and end-systolic leaflet configurations using chordal-mimicking forces, a rigid contact template, and a Gaussian-smoothed locally corrective pressure field. We then generate synthetic chordal insertion sites using zone-based rejection sampling and calibrate the unloaded length of each chord by combining reaction forces with the chordal stress-stretch relationship. The framework was evaluated using Texas TriValve 1.1, a high-fidelity finite element model of a human tricuspid valve validated against beating-heart echocardiography. We found that shape matching reproduced the target end-systolic geometry with a mean inter-surface distance of 0.29 {+/-} 0.35 mm. Moreover, synthetic chordal insertions faithfully reproduce end-systolic leaflet deformations. We subsequently examined synthetic chordal configurations containing 202, 225, and 450 insertions, informed by measurements from eight explanted human tricuspid valves. Here, increasing insertion number reduced mean inter-surface distance from 0.63 {+/-} 0.52 mm to 0.49 {+/-} 0.44 mm and reduced contact area errors from 3.52% to 0.59%. Across all configurations, mean maximum principal stretch errors in leaflet belly regions remained below 2.4%, while areal strain errors ranged from 0.34% to 10.01%. These results demonstrate that anatomically informed shape matching coupled with stress-based chordal calibration can reproduce tricuspid valve closure without explicit subject-specific chordal geometry. This framework provides a foundation for generating synthetic subvalvular anatomy for future imaging-derived, predictive tricuspid valve models.

bioengineering↗