Search bioRxiv⌕ Search

Biology subjects

Schulman, J. B.

Publications and source records attributed to Schulman, J. B..

2 recordsLinked to original sources

Non-Invasive Perfusion Imaging of the Human Brain via Breath-Holding: A DSC MRI Study

Dynamic susceptibility contrast (DSC) MRI plays a pivotal role in the accurate diagnosis and prognosis of several neurovascular diseases, but is limited by its reliance on gadolinium, an intravascularly injected chelated metal. Here, we determined the feasibility of measuring perfusion using a DSC analysis of breath-hold-induced gradient-echo-MRI signal changes. We acquired data at both 3T and 7T from ten healthy participants who engaged in eight consecutive breath-holds. By pairing a novel arterial input function strategy with a standard DSC MRI analysis, we measured the cerebral blood volume, flow, and transit delay, and found values to agree with those documented in the literature using gadolinium. We also observed voxel-wise agreement between breath-hold and arterial spin labeling measures of cerebral blood flow. Breath-holding resulted in significantly higher contrast-to-noise (6.2 at 3T vs 8.5 at 7T) and gray matter-to-white matter contrast at higher field strength. Finally, using a simulation framework to assess the effect of dynamic vasodilation on perfusion estimation, we found global perfusion underestimation of 20-40%. For the first time, we have assessed the feasibility of and limitations associated with using breath-holds for perfusion estimation with DSC. We hope that the methods and results presented in this study will help pave the way toward contrast-free perfusion imaging, in both basic and clinical research.

biophysics↗

Perfusion Quantification in the Human Brain Using DSC MRI - Simulations and Validations at 3T

Gadolinium (Gd) and deoxyhemoglobin (dOHb) are paramagnetic contrast agents capable of inducing changes in T2*-weighted MRI signal, utilized in dynamic susceptibility contrast (DSC) MRI. With multiple contrast agents and analysis choices, there are a variety of questions as to its capability to accurately quantify perfusion values. To address these questions, we developed a novel signal model for DSC MRI that incorporates signal contributions from intravascular and extravascular water proton spins at 3T for arterial, venous, and cerebral tissue voxels. This framework allowed us to model the MRI signal in response to changes in Gd and dOHb concentrations, and the effects that various experimental and tissue parameters have on perfusion quantification. We compared the predictions of the numerical simulations with those obtained from experimental data at 3T on six healthy human subjects using Gd and dOHb boluses as contrast agents. Using standard DSC analysis, we identified perfusion quantification dependencies in the experimental results that were in close agreement with the simulations. We found that a reduced baseline oxygen saturation (base-SaO2), greater susceptibility of applied contrast agent (Gd vs dOHb), and larger magnitude of the hypoxic drop ({Delta}SaO2) reduces overestimation of the cerebral blood volume (rCBV) and flow (rCBF). Furthermore, shortening the bolus duration increases the accuracy and reduces the calculated values of mean transit time (MTT). This study demonstrates that changes in Gd and dOHb can be described by the same unifying theoretical framework, as validated by the experimental results. Based on our work, we suggest practices in DSC MRI that increase accuracy and reduce inter- and intra-subject variability. In uncovering a wide array of quantification dependencies, we argue that caution must be exercised when comparing perfusion values obtained from a standard DSC MRI analysis when employing different experimental paradigms.

biophysics↗