Search bioRxiv⌕ Search

Biology subjects

Schilling, K. G.

Publications and source records attributed to Schilling, K. G..

23 records · Page 2Linked to original sources

Practical gradient non-linearity correction of multi-site diffusion weighted MRI with empirical field maps

BackgroundAchieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. PurposeMagnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study TypeProspective observational study SubjectsA spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell. AssessmentWe compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical TestsWilcoxon rank-sum test between uncorrected and corrected data. ResultsIn phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). ConclusionOur method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.

neuroscience↗

Registration-free Distortion Correction of Diffusion Weighted MRI

Diffusion magnetic resonance images may suffer from geometric distortions due to susceptibility induced off resonance fields, which cause geometric mismatch with anatomical images and ultimately affect subsequent quantification of microstructural or connectivity indices. State-of-the art diffusion distortion correction methods typically require data acquired with reverse phase encoding directions, resulting in varying magnitudes and orientations of distortion, which allow estimation of an undistorted volume. Alternatively, additional field maps acquisitions can be used along with sequence information to determine warping fields. However, not all imaging protocols include these additional scans and cannot take advantage of state-of-the art distortion correction. To avoid additional acquisitions, structural MRI (undistorted scans) can be used as registration targets for intensity driven correction. In this study, we aim to (1) enable susceptibility distortion correction with historical and/or limited diffusion datasets that do not include specific sequences for distortion correction and (2) avoid the computationally intensive registration procedure typically required for distortion correction using structural scans. To achieve these aims, we use deep learning (3D U-nets) to synthesize an undistorted b0 image that matches geometry of structural T1w images and intensity contrasts from diffusion images. Importantly, the training dataset is heterogenous, consisting of varying acquisitions of both structural and diffusion. We apply our approach to a withheld test set and show that distortions are successfully corrected after processing. We quantitatively evaluate the proposed distortion correction and intensity-based registration against state-of-the-art distortion correction (FSL topup). The results illustrate that the proposed pipeline results in b0 images that are geometrically similar to non-distorted structural images, and more closely match state-of-the-art correction with additional acquisitions. In addition, we show generalizability of the proposed approach to datasets that were not in the original training / validation / testing datasets. These datasets included varying populations, contrasts, resolutions, and magnitudes and orientations of distortion and show efficacious distortion correction. The method is available as a Singularity container, source code, and an executable trained model to facilitate evaluation.

bioengineering↗

TractEM: Fast Protocols for Whole Brain Deterministic Tractography-Based White Matter Atlas

Reproducible identification of white matter tracts across subjects is essential for the study of structural connectivity of the human brain. The key challenges are anatomical differences between subjects and human rater subjectivity in labeling. Labeling white matter regions of interest presents many challenges due to the need to integrate both local and global information. Clearly communicating the human/manual processes to capture this information is cumbersome, yet essential to lay a solid foundation for comprehensive atlases. The state-of-the-art for white matter atlas is the single population-averaged Johns Hopkins Eve atlas. A critical bottleneck with the Eve atlas framework is that manual labeling time is extensive and peripheral white matter regions are conservatively labeled. In this work, we developed protocols that will facilitate manual virtual dissection of white matter pathways, with the goals to be anatomically accurate, intuitive, reproducible, and act as an initial stage to build an amenable knowledge base of neuroanatomical regions. We analyzed reproducibility of the fiber bundles and variability of human raters using DICE correlation coefficient, intraclass correlation coefficient, and root mean squared error. The protocols at their initial stage have shown promising results on both typical 3T research acquisition Baltimore Longitudinal Study of Aging and high-acquisition quality Human Connectome Project datasets. The TractEM manual labeling protocols allow for reconstruction of reproducible subject-specific fiber bundles across the brain. The protocols and sample results have been made available in open source to improve generalizability and reliability in collaboration.

neuroscience↗

Histologically derived fiber response functions for diffusion MRI vary across white matter fibers - an ex vivo validation study in the squirrel monkey brain

Understanding the relationship between the diffusion-weighted MRI signal and the arrangement of white matter fibers is fundamental for accurate voxel-wise reconstruction of the fiber orientation distribution (FOD) and subsequent fiber tractography. Spherical deconvolution reconstruction techniques model the diffusion signal as the convolution of the FOD with a response function which represents the signal profile of a single fiber orientation. Thus, given the signal and a fiber response function, the FOD can be estimated in every imaging voxel by deconvolution. However, the selection of the appropriate response function remains relatively un-studied, and requires further validation. In this work, using 3D histologically-defined FODs and the corresponding diffusion signal from three ex vivo squirrel monkey brains, we derive the ground truth response functions. We find that the histologically-derived response functions differ from those conventionally used. Next, we find that response functions statistically vary across brain regions, which suggests that the practice of using the same kernel throughout the brain is not optimal. Additionally, response functions vary significantly across subjects. We show that different kernels lead to different FOD reconstructions, which in turn can lead to different tractography results depending on algorithmic parameters, with large variations in the accuracy of resulting reconstructions. Together, this suggests that there is room for improvement in estimating and understanding the relationship between the diffusion signal and the underlying FOD.

neuroscience↗

Limits to anatomical accuracy of diffusion tractography using modern approaches

Diffusion MRI fiber tractography is widely used to probe the structural connectivity of thebrain, with a range of applications in both clinical and basic neuroscience. Despite widespread use, tractography has well-known pitfalls that limits the anatomical accuracy of this technique. Numerous modern methods have been developed to address these shortcomings through advances in acquisition, modeling, and computation. To test whether these advances improve tractography accuracy, we organized the ISBI 2018 3D Validation of Tractography with Experimental MRI (3D-VoTEM) challenge. We made available three unique independent tractography validation datasets - a physical phantom and two ex vivo brain specimens - resulting in 176 distinct submissions from 9 research groups. By comparing results over a wide range of fiber complexities and algorithmic strategies, this challenge provides a more comprehensive assessment of tractographys inherent limitations than has been reported previously. The central results were consistent across all sub-challenges in that, despite advances in tractography methods, the anatomical accuracy of tractography has not dramatically improved in recent years. Taken together, our results independently confirm findings from decades of tractography validation studies, demonstrate inherent limitations in reconstructing white matter pathways using diffusion MRI data alone, and highlight the need for alternative or combinatorial strategies to accurately map the fiber pathways of the brain.

neuroscience↗