Search bioRxiv⌕ Search

Biology subjects

Schellhorn, K.

Publications and source records attributed to Schellhorn, K..

2 recordsLinked to original sources

Carbonized rubber electrodes can cause a DC-offset in transcranial alternating current stimulation

IntroductionCarbonized rubber electrodes are widely used in non-invasive brain stimulation studies. Due to their polarizable nature, however, they can cause a voltage offset, which might be problematic for concurrent EEG studies. ObjectiveIn this study, we aim to describe the voltage offset and ensure that the offset does not alter the intended waveform of applied stimulation. MethodsUsing data from 2 human studies and phantom measurements, which employed carbonized rubber electrodes, we quantify the magnitude and frequency of DC-offsets and contrast this against pilot-measurements using Ag/AGCl-electrodes. In a further phantom study, we record the offset-voltage that arises from the electrode/electrolyte interface and compare this to the voltage put out by the stimulation device. ResultsA non-zero voltage offset is present in all human and phantom studies employing carbonized rubber electrodes, while the offset using Ag/AgCl electrodes is close to zero. Direct measurements of the stimulator output in the presence of a measurable voltage offset at the stimulation electrodes shows that the offset originates from the electrodes and not from the current provided by the stimulation device. ConclusionUsing carbonized rubber-electrodes for stimulation can result in the emergence of a measurable voltage offset, due to their polarizable nature. We argue that this offset can be problematic in concurrent EEG recordings, as they pose the risk of amplifier saturation and distortions of the recorded stimulation waveform.

neuroscience↗

Characterizing Low-Frequency Artifacts During Transcranial Temporal Interference Stimulation (tTIS)

Transcranial alternating current stimulation (tACS) is a well-established brain stimulation technique to modulate human brain oscillations. However, due to the strong electro-magnetic artifacts induced by the stimulation current, the simultaneous measurement of tACS effects during neurophysiological recordings in humans is challenging. Recently, transcranial temporal interference stimulation (tTIS) has been introduced to stimulate neurons at depth non-invasively. During tTIS, two high-frequency sine waves are applied, that interfere inside the brain, resulting in amplitude modulated waveforms at the target frequency. Given appropriate hardware, we show that neurophysiological data during tTIS may be acquired without stimulation artifacts at low-frequencies. However, data must be inspected carefully for possible low-frequency artifacts. Our results may help to design experimental setups to record brain activity during tTIS, which may foster our understanding of its underlying mechanisms.

neuroscience↗