Search bioRxiv⌕ Search

Biology subjects

Sanderson, N.

Publications and source records attributed to Sanderson, N..

4 recordsLinked to original sources

Topological analysis of neuronal assemblies reveals low-rank structure modulated by cholinergic activity

1Neuronal assemblies are fundamental building blocks of brain function (e.g. memory, spatial navigation, eye fixation, etc.). However, the principles underlying the connectivity patterns that support their function have remained elusive. The optic tectum of the zebrafish larva is organized into distinct functional neuronal assemblies. These assemblies display all-or-none preferred activation states and inhibitory competition, mechanisms that improve the decoding of visual information. Here, we combined light-sheet microscopy to capture the dynamics of large neuronal networks ([~]2,000 neurons) in the optic tectum; genetic cell-type markers for studying the physiological and functional properties of tectal assemblies; and techniques from topological data analysis to study the dynamic connectivity patterns that enable the emergence and functional role of the neuronal assemblies. We found that during spontaneous activations, tectal assemblies maintain a tight and stable ratio of E-I activity despite the large increase in activity. Topological analysis of the spontaneous activations indicated a low-rank organization of the assemblies and a discrete number of temporal activation patterns. Finally, we observed that the cholinergic system can modulate the topological features of the assemblies to alter their functional role.

neuroscience↗

Comparison of long-read sequencing technologies in the hybrid assembly of complex bacterial genomes

Illumina sequencing allows rapid, cheap and accurate whole genome bacterial analyses, but short reads (<300 bp) do not usually enable complete genome assembly. Long read sequencing greatly assists with resolving complex bacterial genomes, particularly when combined with short-read Illumina data (hybrid assembly). However, it is not clear how different long-read sequencing methods impact on assembly accuracy. Relative automation of the assembly process is also crucial to facilitating high-throughput complete bacterial genome reconstruction, avoiding multiple bespoke filtering and data manipulation steps. In this study, we compared hybrid assemblies for 20 bacterial isolates, including two reference strains, using Illumina sequencing and long reads from either Oxford Nanopore Technologies (ONT) or from SMRT Pacific Biosciences (PacBio) sequencing platforms. We chose isolates from the Enterobacteriaceae family, as these frequently have highly plastic, repetitive genetic structures and complete genome reconstruction for these species is relevant for a precise understanding of the epidemiology of antimicrobial resistance. We de novo assembled genomes using the hybrid assembler Unicycler and compared different read processing strategies. Both strategies facilitate high-quality genome reconstruction. Combining ONT and Illumina reads fully resolved most genomes without additional manual steps, and at a lower consumables cost per isolate in our setting. Automated hybrid assembly is a powerful tool for complete and accurate bacterial genome assembly. IMPACT STATEMENTIllumina short-read sequencing is frequently used for tasks in bacterial genomics, such as assessing which species are present within samples, checking if specific genes of interest are present within individual isolates, and reconstructing the evolutionary relationships between strains. However, while short-read sequencing can reveal significant detail about the genomic content of bacterial isolates, it is often insufficient for assessing genomic structure: how different genes are arranged within genomes, and particularly which genes are on plasmids - potentially highly mobile components of the genome frequently carrying antimicrobial resistance elements. This is because Illumina short reads are typically too short to span repetitive structures in the genome, making it impossible to accurately reconstruct these repetitive regions. One solution is to complement Illumina short reads with long reads generated with SMRT Pacific Biosciences (PacBio) or Oxford Nanopore Technologies (ONT) sequencing platforms. Using this approach, called hybrid assembly, we show that we can automatically fully reconstruct complex bacterial genomes of Enterobacteriaceae isolates in the majority of cases (best-performing method: 17/20 isolates). In particular, by comparing different methods we find that using the assembler Unicycler with Illumina and ONT reads represents a low-cost, high-quality approach for reconstructing bacterial genomes using publicly available software. DATA SUMMARYRaw sequencing data and assemblies have been deposited in NCBI under BioProject Accession PRJNA422511 (https://www.ncbi.nlm.nih.gov/bioproject/PRJNA422511). We confirm all supporting data, code and protocols have been provided within the article or through supplementary data files.

bioinformatics↗

MinION Nanopore Sequencing of Multiple Displacement Amplified Mycobacteria DNA Direct from Sputum

Sequencing of pathogen DNA directly from clinical samples offers the possibilities of rapid diagnosis, faster antimicrobial resistance prediction and enhanced outbreak investigation. The approach is especially advantageous for infections caused by species which grow very slowly in culture, such as Mycobacteria tuberculosis. Since the pathogen of interest may represent as little as 0.01% of the total DNA, enrichment of the input material for target sequences by specific amplification and, or depletion of non-target DNA (human, other bacteria) is essential for success. Here, we investigated the potential of isothermal multiple displacement amplification by Phi29 polymerase. We directed the amplification reaction towards Mycobacteria DNA in sputum samples by exploiting in our oligonucleotide primer design, their high GC content (approximately 65%) relative to human DNA. Amplified DNA was then sequenced using the Oxford Nanopore Technology MinION. In addition, a model system comprising standardised mock clinical samples was designed. Pooled infection negative human sputum samples were spiked with enumerated Mycobacterium bovis (BCG) Pasteur strain at concentrations spanning the typical range at which Mycobacterium tuberculosis is found in human sputum samples (106 - 101 BCG cells/ml). To assess the amount of BCG sequence enrichment achieved, sample DNA was sequenced both before, and after amplification. Reads from amplified samples, which mapped to a BCG reference genome, comprised short repeated sequences - apparently transcribed multiple times from the same fragment of BCG DNA. Therefore post-amplification, the samples were enriched for BCG sequences relative to unamplified sequences (8,101 BCG reference mapped reads, increasing to 28,617 at 106 BCG cells/ml sample), but BCG genome coverage declined markedly (for example 89.4% to 4.1%). In summary, the use of standardised mock clinical samples allowed direct comparison of data from different Mycobacteria enrichment experiments and sequencing runs. However, optimal conditions for multiple displacement amplification of minority Mycobacteria DNAs, remain to be identified.

microbiology↗

Same-day diagnostic and surveillance data for tuberculosis via whole genome sequencing of direct respiratory samples.

Routine full characterization of Mycobacterium tuberculosis (TB) is culture-based, taking many weeks. Whole-genome sequencing (WGS) can generate antibiotic susceptibility profiles to inform treatment, augmented with strain information for global surveillance; such data could be transformative if provided at or near point of care.\n\nWe demonstrate a low-cost DNA extraction method for TB WGS direct from patient samples. We initially evaluated the method using the Illumina MiSeq sequencer (40 smear-positive respiratory samples, obtained after routine clinical testing, and 27 matched liquid cultures). M. tuberculosis was identified in all 39 samples from which DNA was successfully extracted. Sufficient data for antibiotic susceptibility prediction was obtained from 24 (62%) samples; all results were concordant with reference laboratory phenotypes. Phylogenetic placement was concordant between direct and cultured samples. Using an Illumina MiSeq/MiniSeq the workflow from patient sample to results can be completed in 44/16 hours at a cost of {pound}96/{pound}198 per sample.\n\nWe then employed a non-specific PCR-based library preparation method for sequencing on an Oxford Nanopore Technologies MinION sequencer. We applied this to cultured Mycobacterium bovis BCG strain (BCG), and to combined culture-negative sputum DNA and BCG DNA. For the latest flowcell, the estimated turnaround time from patient to identification of BCG was 6 hours, with full susceptibility and surveillance results 2 hours later. Antibiotic susceptibility predictions were fully concordant. A critical advantage of the MinION is the ability to continue sequencing until sufficient coverage is obtained, providing a potential solution to the problem of variable amounts of M. tuberculosis in direct samples.

microbiology↗