Search bioRxivSearch

Biology subjects

Salisbury, J. L.

Publications and source records attributed to Salisbury, J. L..

5 recordsLinked to original sources

Practices for Measuring 3D Organelle Morphology and Generating Surfaces with Amira

Analysis of 3D structures is of paramount importance in cellular biology. Although light microscopy and transmission electron microscopy (TEM) have remained staples for imaging cellular structures, they lack the ability to image in 3D. However, recent technological advances, such as serial block-face scanning electron microscopy (SBF-SEM) and focused ion beam scanning electron microscopy (FIB-SEM), have allowed researchers to observe cellular ultrastructure in 3D. Here, we propose a standardized protocol using the visualization software Amira to quantify organelle morphologies in 3D; this method allows researchers to produce accurate and reproducible measurements of cellular structure characteristics. We demonstrate this applicability by utilizing SBF-SEM and Amira to quantify mitochondria and endoplasmic reticulum (ER) structures. GRAPHICAL ABSTRACT O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=127 SRC="FIGDIR/small/461807v1_ufig1.gif" ALT="Figure 1"> View larger version (43K): org.highwire.dtl.DTLVardef@1c40041org.highwire.dtl.DTLVardef@ecde92org.highwire.dtl.DTLVardef@10870daorg.highwire.dtl.DTLVardef@1290c3b_HPS_FORMAT_FIGEXP M_FIG C_FIG

biophysics

Systematic Transmission Electron Microscopy-Based Identification of Cellular Degradation Machinery

Many interconnected degradation machineries including autophagosomes, lysosomes, and endosomes work in tandem to conduct autophagy, an intracellular degradation system that is crucial for cellular homeostasis. Altered autophagy contributes to the pathophysiology of various diseases, including cancers and metabolic diseases. Although many studies have investigated autophagy to elucidate disease pathogenesis, identification of specific components of the autophagy machinery has been challenging. The goal of this paper is to describe an approach to reproducibly identify and distinguish subcellular structures involved in macro autophagy. We provide methods that help avoid common pitfalls, including a detailed explanation for distinguishing lysosomes and lipid droplets and discuss differences between autophagosomes and inclusion bodies. These methods are based on using transmission electron microscopy (TEM), capable of generating nanometer-scale micrographs of cellular degradation components in a fixed sample. We also utilize serial block face-scanning electron microscopy (SBF-SEM) to offer a protocol for visualizing 3D morphology of degradation machinery. In addition to TEM and 3D reconstruction, we discuss other imaging techniques, such as immunofluorescence and immunogold labeling that can be utilized to reliably and accurately classify cellular organelles. Our results show how these methods may be used to accurately quantify the cellular degradation machinery under various conditions, such as treatment with the endoplasmic reticulum stressor thapsigargin or ablation of the dynamin-related protein 1.

biophysics

A comprehensive approach for artifact-free sample preparation and assessment of mitochondrial morphology in tissue and cultured cells

Mitochondrial dynamics (fission, fusion, and the formation of nanotunnels) and morphology are very sensitive to the cellular environment. Mitochondria may be adversely affected by oxidative stress, changes in calcium levels, and hypoxia. Investigating the precise relationship between organelle structure and function requires methods that can adequately preserve mitochondria while providing accurate, quantitative measurements of morphological attributes. Here, we demonstrate a practical approach for preserving and measuring fine structural changes using two-dimensional, high-resolution electron micrographs. This approach is further applicable for three-dimensional volume renderings, obtained using serial block-face and focused ion beam-scanning electron microscopy, highlighting the specific advantages of these techniques. Additionally, this study defines a set of quantifiable metrics that can be applied to measure mitochondrial architecture and other organellar structures. Finally, we validated specimen preparation methods that avoid the introduction of morphological artifacts that may interfere with mitochondrial appearance and do not require whole-animal perfusion.

cell biology

A Universal Approach to Analyzing Transmission Electron Microscopy with ImageJ

2Transmission electron microscopy (TEM) is a scientific research standard for producing nanometer-resolution ultrastructural images of subcellular components within cells and tissues. Mitochondria, endoplasmic reticulum (ER), lysosomes, and autophagosomes are organelles of particular interest to those investigating metabolic disorders. However, there is no clear consensus amongst regarding the best methods for quantifying the features of organelles in TEM images. In this protocol, we propose a standardized approach to accurately measure the morphology of these important subcellular structures using the free program ImageJ, developed by the National Institutes of Health (NIH). Specifically, we detail procedures for obtaining mitochondrial length, width, area, and circularity, in addition to assessing cristae morphology. We further provide methods for measuring interactions between the mitochondria and ER and measuring the length and width of lysosomes and autophagosomes. This standardized method can be used to quantify key features of organelle morphology, allowing investigators to produce accurate and reproducible measurements of organelle structures in their experimental samples. 1 SUMMARYWe discuss a standardized method for measuring and quantifying organelle features using transmission electron microscopy and accessing for interactions between subcellular structures; organelles of focus include mitochondria, endoplasmic reticulum, lysosomes, and autophagosomes.

biophysics

Partial inhibition of mitochondrial complex I attenuates neurodegeneration and restores energy homeostasis and synaptic function in a symptomatic Alzheimers mouse model

We demonstrate that mitochondrial respiratory chain complex I is an important small molecule druggable target in Alzheimers Disease (AD). Partial inhibition of complex I triggers the AMP-activated protein kinase-dependent signaling network leading to neuroprotection in symptomatic APP/PS1 mice, a translational model of AD. Treatment of APP/PS1 mice with complex I inhibitor after the onset of AD-like neuropathology improved energy homeostasis, synaptic activity, long-term potentiation, dendritic spine maturation, cognitive function and proteostasis, and reduced oxidative stress and inflammation in brain and periphery, ultimately blocking the ongoing neurodegeneration. Therapeutic efficacy in vivo was monitored using translational biomarkers FDG-PET, 31P NMR, and metabolomics. Cross-validation of the mouse and the human AMP-AD transcriptomic data demonstrated that pathways improved by the treatment in APP/PS1 mice, including the immune system response and neurotransmission, represent mechanisms essential for therapeutic efficacy in AD patients.

neuroscience