On the accuracy of image registration in portable low-field 3D brain MRI

Portable low-field MRI offers an affordable and mobile alternative to conventional high-field scanners, enabling imaging in point-of-care and resource-limited settings. However, its lower signal-to-noise ratio, reduced resolution, and acquisition artifacts raise concerns about the accuracy of standard image registration methods. Reliable registration is critical for a wide range of emerging applications, including frequent brain monitoring, assessment of neurodegenerative disease progression, and evaluation of treatment effects such as those of Alzheimers therapeutics. In this work, we systematically evaluated state-of-the-art registration approaches on simulated low-field scans (obtained by downsampling high-field images) and on real low-field brain MRI data. We compared three representative approaches: classical optimization (NiftyReg), learning-based registration (SynthMorph), and synthesis-based registration (SynthSR+NiftyReg). Using downsampled high-field scans, all methods performed well, achieving high Dice scores and smooth deformation fields, indicating that reduced resolution alone does not hinder registration. In contrast, real low-field data exhibited lower accuracy, primarily due to geometric distortion and other acquisition-specific artifacts. Among the tested approaches, the synthesis-based pipeline achieved the most robust performance across subjects and modalities. Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.

neuroscience↗

AI boosted molecular MRI for apoptosis detection in oncolytic virotherapy

Oncolytic virotherapy is a promising treatment for high mortality cancers1. Non-invasive imaging of the underlying molecular processes is an essential tool for therapy optimization and assessment of viral spread, innate immunity, and therapeutic response2, 3. However, previous methods for imaging oncolytic viruses did not correlate with late viral activity4 or had poor sensitivity and specificity5. Similarly, methods developed to image treatment response, such as apoptosis, proved to be slow, nonspecific, or require the use of radioactive or metal-based contrast agents6-8. To date, no method has been widely adopted for clinical use. We describe here a new method for fast magnetic resonance molecular imaging with quantitative proton chemical-exchange specificity to monitor oncolytic virotherapy treatment response. A deep neural network enabled the computation of quantitative biomarker maps of protein and lipid/macromolecule concentrations as well as intracellular pH in a glioblastoma multiforme mouse brain tumor model. Early detection of apoptotic response to oncolytic virotherapy, characterized by decreased cytosolic pH and protein synthesis, was observed in agreement with histology. Clinical translation was demonstrated in a normal human subject, yielding molecular parameters in good agreement with literature values9. The developed method is directly applicable to a wide range of pathologies, including stroke10, cancer11-13, and neurological disorders14, 15.

biophysics↗