Search bioRxiv⌕ Search

Biology subjects

Rogan, P. K.

Publications and source records attributed to Rogan, P. K..

10 recordsLinked to original sources

Radiation Exposure Determination in a Secure, Cloud-based Online Environment

Rapid sample processing and interpretation of estimated exposures will be critical for triaging exposed individuals after a major radiation incident. The dicentric chromosome (DC) assay assesses absorbed radiation using metaphase cells from blood. The Automated Dicentric Chromosome Identifier and Dose Estimator System (ADCI) identifies DCs and determines radiation doses. This study aimed to broaden accessibility and speed of this system, while protecting data and software integrity. ADCI Online is a secure web-streaming platform accessible worldwide from local servers. Cloud-based systems containing data and software are separated until they are linked for radiation exposure estimation. Dose estimates are identical to ADCI on dedicated computer hardware. Image processing and selection, calibration curve generation, and dose estimation of 9 test samples completed in <2 days. ADCI Online has the capacity to alleviate analytic bottlenecks in intermediate-to-large radiation incidents. Multiple cloned software instances configured on different cloud environments accelerated dose estimation to within clinically relevant time frames.

bioinformatics↗

Improved radiation expression profiling by sequential application of sensitive and specific gene signatures

PurposeCombinations of expressed genes can discriminate radiation-exposed from normal control blood samples by machine learning based signatures (with 8 to 20% misclassification rates). These signatures can quantify therapeutically-relevant as well as accidental radiation exposures. The prodromal symptoms of Acute Radiation Syndrome (ARS) overlap those present in Influenza and Dengue Fever infections. Surprisingly, these human radiation signatures misclassified gene expression profiles of virally infected samples as false positive exposures. The present study investigates these and other confounders, and then mitigates their impact on signature accuracy. MethodsThis study investigated recall by previous and novel radiation signatures independently derived from multiple Gene Expression Omnibus datasets on common and rare non-malignant blood disorders and blood-borne infections (thromboembolism, S. aureus bacteremia, malaria, sickle cell disease, polycythemia vera, and aplastic anemia). Normalized expression levels of signature genes are used as input to machine learning-based classifiers to predict radiation exposure in other hematological conditions. ResultsExcept for aplastic anemia, these blood-borne disorders modify the normal baseline expression values of genes present in radiation signatures, leading to false-positive misclassification of radiation exposures in 8 to 54% of individuals. Shared changes, predominantly in DNA damage response and apoptosis-related gene transcripts in radiation and confounding hematological conditions, compromise the utility of these signatures for radiation assessment. These confounding conditions (sickle cell disease, thromboembolism, S. aureus bacteremia, malaria) induce neutrophil extracellular traps, initiated by chromatin decondensation, DNA damage response and fragmentation followed by programmed cell death. Riboviral infections (for example, Influenza or Dengue fever) have been proposed to bind and deplete host RNA binding proteins, inducing R-loops in chromatin. R-loops that collide with incoming replication forks can result in incompletely repaired DNA damage, inducing apoptosis and releasing mature virus. To mitigate the effects of confounders, we evaluated predicted radiation-positive samples with novel gene expression signatures derived from radiation-responsive transcripts encoding secreted blood plasma proteins whose expression levels are unperturbed by these conditions. ConclusionsThis approach identifies and eliminates misclassified samples with underlying hematological or infectious conditions, leaving only samples with true radiation exposures. Diagnostic accuracy is significantly improved by selecting genes that maximize both sensitivity and specificity in the appropriate tissue using combinations of the best signatures for each of these classes of signatures.

systems biology↗

Pathway-extended gene expression signatures integrate novel biomarkers that improve predictions of patient responses to kinase inhibitors

Cancer chemotherapy responses have been related to multiple pharmacogenetic biomarkers, often for the same drug. This study utilizes machine learning to derive multi-gene expression signatures that predict individual patient responses to specific tyrosine kinase inhibitors, including erlotinib, gefitinib, sorafenib, sunitinib, lapatinib and imatinib. Support Vector Machine learning was used to train mathematical models that distinguished sensitivity from resistance to these drugs using a novel systems biology-based approach. This began with expression of genes previously implicated in specific drug responses, then expanded to evaluate genes whose products were related through biochemical pathways and interactions. Optimal pathway-extended support vector machines predicted responses in patients at accuracies of 70% (imatinib), 71% (lapatinib), 83% (sunitinib), 83% (erlotinib), 88% (sorafenib) and 91% (gefitinib). These best performing pathway-extended models demonstrated improved balance predicting both sensitive and resistant patient categories, with many of these genes having a known role in cancer etiology. Ensemble machine learning-based averaging of multiple pathway-extended models derived for an individual drug increased accuracy to >70% for erlotinib, gefitinib, lapatinib, and sorafenib. Through incorporation of novel cancer biomarkers, machine learning-based pathway-extended signatures display strong efficacy predicting both sensitive and resistant patient responses to chemotherapy.

pharmacology and toxicology↗

Estimating partial body ionizing radiation exposure by automated cytogenetic biodosimetry

PurposeInhomogeneous exposures to ionizing radiation can be detected and quantified with the Dicentric Chromosome Assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole body irradiation has significantly improved throughput without compromising accuracy, however low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial body exposure determination. Materials and MethodsWe describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method. ResultsDose estimates of three partially irradiated samples diverged 0.2 to 2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3-15.8% from the known levels. Synthetic partial body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy2 and from 8.1 to 33.3%2 for the fraction of cells irradiated. ConclusionsAutomated DCA can differentiate whole-from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose. Biographical NoteBen Shirley M.Sc. is Chief Software Architect, CytoGnomix Inc. Canada; Joan Knoll Ph.D. Dipl.ABMGG, FCCMG is Professor in Pathology and Laboratory Medicine, Schulich School of Medicine and Dentistry, University of Western Ontario, Canada and cofounder, CytoGnomix Inc.; Jayne Moquet Ph.D. is Principal Radiation Protection Scientist in the Cytogenetics Group, Public Health England; Elizabeth Ainsbury Ph.D. is Head, Cytogenetics Group and the Chromosome Dosimetry Service, Public Health England; Pham Ngoc Duy M.Sc. is deputy director of Biotechnology Center, Dalat Nuclear Research Institute, Vietnam; Farrah Norton M.Sc.is Research Scientist and Lead of the Biodosimetry emergency response and research capability at Canadian Nuclear Laboratories; Ruth Wilkins, Ph.D. is Research Scientist and Chief of the Ionizing Radiation Health Sciences Division at Health Canada, Ontario, Canada; and Peter K. Rogan Ph.D. is Professor of Biochemistry and Oncology, Schulich School of Medicine and Dentistry, University of Western Ontario, Canada, and President, CytoGnomix Inc.

genetics↗

Automated Cytogenetic Biodosimetry at Population-Scale

IntroductionThe dicentric chromosome (DC) assay accurately quantifies exposure to radiation, however manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator Chromosome (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. We present high performance ADCI (ADCI-HT), with the requisite throughput to stratify exposures of populations in large scale radiation events.\n\nMethodsADCI-HT streamlines dose estimation by optimal scheduling of DC detection, given that the numbers of samples and metaphase cell images in each sample vary. A supercomputer analyzes these data in parallel, with each processor handling a single image at a time. Processor resources are managed hierarchically to maximize a constant stream of sample and image analysis. Metaphase data from populations of individuals with clinically relevant radiation exposures after simulated large nuclear incidents were analyzed. Sample counts were derived from US Census data. Analysis times and exposures were quantified for 15 different scenarios.\n\nResultsProcessing of metaphase images from 1,744 samples (500 images each) used 16,384 CPUs and was completed in 1hr 11min 23sec, with radiation dose of all samples determined in 32 sec with 1,024 CPUs. Processing of 40,000 samples with varying numbers of metaphase cells, 10 different exposures from 5 different biodosimetry labs met IAEA accuracy criteria (dose estimate differences were < 0.5 Gy; median = 0.07) and was completed in ~25 hours. Population-scale metaphase image datasets within radiation contours of nuclear incidents were defined by exposure levels (either >1 Gy or >2 Gy). The time needed to analyze samples of all individuals receiving exposures from a high yield airborne nuclear device ranged from 0.6-7.4 days, depending on the population density.\n\nConclusionADCI-HT delivers timely and accurate dose estimates in a simulated population-scale radiation incident.

bioinformatics↗

Expression changes confirm predicted single nucleotide variants affecting mRNA splicing

Splice isoform structure and abundance can be affected by either non-coding or masquerading coding variants that alter the structure or abundance of transcripts. When these variants are common in the population, these non-constitutive transcripts are sufficiently frequent so as to resemble naturally occurring, alternative mRNA splicing. Prediction of the effects of such variants has been shown to be accurate using information theory-based methods. Single nucleotide polymorphisms (SNPs) predicted to significantly alter natural and/or cryptic splice site strength were shown to affect gene expression. Splicing changes for known SNP genotypes were confirmed in HapMap lymphoblastoid cell lines with gene expression microarrays and custom designed q-RT-PCR or TaqMan assays. The majority of these SNPs (15 of 22) as well as an independent set of 24 variants were then subjected to RNAseq analysis using the ValidSpliceMut web beacon (http://validsplicemut.cytognomix.com), which is based on data from the Cancer Genome Atlas and International Cancer Genome Consortium. SNPs from different genes analyzed with gene expression microarray and q-RT-PCR exhibited significant changes in affected splice site use. Thirteen SNPs directly affected exon inclusion and 10 altered cryptic site use. Homozygous SNP genotypes resulting in stronger splice sites exhibited higher levels of processed mRNA than alleles associated with weaker sites. Four SNPs exhibited variable expression among individuals with the same genotypes, masking statistically significant expression differences between alleles. Genome-wide information theory and expression analyses (RNAseq) in tumour exomes and genomes confirmed splicing effects for 7 of the HapMap SNP and 14 SNPs identified from tumour genomes. q-RT-PCR resolved rare splice isoforms with read abundance too low for statistical significance in ValidSpliceMut. Nevertheless, the web-beacon provides evidence of unanticipated splicing outcomes, for example, intron retention due to compromised recognition of constitutive splice sites. Thus, ValidSpliceMut and q-RT-PCR represent complementary resources for identification of allele-specific, alternative splicing.

genomics↗

Pan-Cancer Repository of Validated Natural and Cryptic mRNA Splicing Mutations

We present a major public resource of mRNA splicing mutations validated according to multiple lines of evidence of abnormal gene expression. Likely mutations present in all tumor types reported in the Cancer Genome Atlas (TCGA) were identified based on the comparative strengths of splice sites in tumor versus normal genomes and then validated by respectively comparing counts of splice junction spanning and abundance of transcript reads in RNA-Seq data from matched tissues and tumors lacking these mutations. The comprehensive resource features 351,423 of these validated mutations, the majority of which (69.1%) are not featured in the Single Nucleotide Polymorphism Database (dbSNP 150). There are 117,951 unique mutations which weaken or abolish natural splice sites, and 244,415 mutations which strengthen cryptic splice sites (10,943 affect both simultaneously). 27,803 novel or rare flagged variants (with <1% population frequency in dbSNP) were observed in multiple tumor tissue types. Single variants or chromosome ranges can be queried using a Global Alliance for Genomics and Health (GA4GH)-compliant web Beacon, Validated Splicing Mutations, either separately or in aggregate alongside other beacons through the public Beacon Network (http://www.beacon-network.org/#/search?beacon=cytognomix), as well as through our website (https://validsplicemut.cytognomix.com/).

genomics↗

Clustered, information-dense transcription factor binding sites identify genes with similar tissue-wide expression profiles

BackgroundThe distribution and composition of cis-regulatory modules (e.g. transcription factor binding site (TFBS) clusters) in promoters substantially determine gene expression patterns and TF targets, whose expression levels are significantly regulated by TF binding. TF knockdown experiments have revealed correlations between TF binding profiles and gene expression levels. We present a general framework capable of predicting genes with similar tissue-wide expression patterns from activated or repressed TF targets using machine learning to combine TF binding and epigenetic features.\n\nMethodsGenes with correlated expression patterns across 53 tissues were identified according to their Bray-Curtis similarity. DNase I HyperSensitive region (DHS) -accessible promoter intervals of direct TF target genes were scanned with previously derived information theory-based position weight matrices (iPWMs) of 82 TFs. Features from information density-based TFBS clusters were used to predict target genes with machine learning classifiers. The accuracy, specificity and sensitivity of the classifiers were determined for different feature sets. Mutations in TFBSs were also introduced to examine their impact on cluster densities and the regulatory states of predicted target genes.\n\nResultsWe initially chose the glucocorticoid receptor gene (NR3C1), whose regulation has been extensively studied, to test this approach. SLC25A32 and TANK were found to exhibit the most similar expression patterns to this gene across 53 tissues. Prediction of other genes with similar expression profiles was significantly improved by eliminating inaccessible promoter intervals based on DHSs. A Random Forest classifier exhibited the best performance in detecting such coordinately regulated genes (accuracy was 0.972 for training, 0.976 for testing). Target gene prediction was confirmed using CRISPR knockdown data of TFs, which was more accurate than siRNA inactivation. Mutation analyses of TFBSs also revealed that one or more information-dense TFBS clusters in promoters are required for accurate target gene prediction.\n\nConclusionsMachine learning based on TFBS information density, organization, and chromatin accessibility accurately identifies gene targets with comparable tissue-wide expression patterns. Multiple, information-dense TFBS clusters in promoters appear to protect promoters from the effects of deleterious binding site mutations in a single TFBS that would effectively alter the expression state of these genes.

bioinformatics↗

Predicting Response to Platin Chemotherapy Agents with Biochemically-inspired Machine Learning

Selection of effective genes that accurately predict chemotherapy response could improve cancer outcomes. We compare optimized gene signatures for cisplatin, carboplatin, and oxaliplatin response in the same cell lines, and respectively validate each with cancer patient data. Supervised support vector machine learning was used to derive gene sets whose expression was related to cell line GI50 values by backwards feature selection with cross-validation. Specific genes and functional pathways distinguishing sensitive from resistant cell lines are identified by contrasting signatures obtained at extreme vs. median GI50 thresholds. Ensembles of gene signatures at different thresholds are combined to reduce dependence on specific GI50 values for predicting drug response. The most accurate models for each platin are: cisplatin: BARD1, BCL2, BCL2L1, CDKN2C, FAAP24, FEN1, MAP3K1, MAPK13, MAPK3, NFKB1, NFKB2, SLC22A5, SLC31A2, TLR4, TWIST1; carboplatin: AKT1, EIF3K, ERCC1, GNGT1, GSR, MTHFR, NEDD4L, NLRP1, NRAS, RAF1, SGK1, TIGD1, TP53, VEGFB, VEGFC; oxaliplatin: BRAF, FCGR2A, IGF1, MSH2, NAGK, NFE2L2, NQO1, PANK3, SLC47A1, SLCO1B1, UGT1A1. TCGA bladder, ovarian and colorectal cancer patients were used to test cisplatin, carboplatin and oxaliplatin signatures (respectively), resulting in 71.0%, 60.2% and 54.5% accuracy in predicting disease recurrence and 59%, 61% and 72% accuracy in predicting remission. One cisplatin signature predicted 100% of recurrence in non-smoking bladder cancer patients (57% disease-free; N=19), and 79% recurrence in smokers (62% disease-free; N=35). This approach should be adaptable to other studies of chemotherapy response, independent of drug or cancer types.

pharmacology and toxicology↗

Accurate Cytogenetic Biodosimetry Through Automation Of Dicentric Chromosome Curation And Metaphase Cell Selection

Software to automate digital pathology relies on image quality and the rates of false positive and negative objects in these images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received from the frequency of DCs. We present image segmentation methods to rank high quality cytogenetic images and eliminate suboptimal metaphase cell data based on novel quality measures. Improvements in DC recognition increase the accuracy of dose estimates, by reducing false positive (FP) DC detection. A set of chromosome morphology segmentation methods selectively filtered out false DCs, arising primarily from extended prometaphase chromosomes, sister chromatid separation and chromosome fragmentation. This reduced FPs by 55% and was highly specific to the abnormal structures ([&ge;]97.7%). Additional procedures were then developed to fully automate image review, resulting in 6 image-level filters that, when combined, selectively remove images with consistently unparsable or incorrectly segmented chromosome morphologies. Overall, these filters can eliminate half of the FPs detected by manual image review. Optimal image selection and FP DCs are minimized by combining multiple feature based segmentation filters and a novel image sorting procedure based on the known distribution of chromosome lengths. Applying the same segmentation filtering procedures to both calibration and test sample image data reduced the average dose estimation error from 0.4Gy to <0.2Gy, obviating the need to first manually review these images. This reliable and scalable solution enables batch processing multiple samples of unknown dose, and meets current requirements for triage radiation biodosimetry of high quality metaphase cell preparations.

genetics↗