Search bioRxiv⌕ Search

Biology subjects

Rodgers, C. T.

Publications and source records attributed to Rodgers, C. T..

8 recordsLinked to original sources

Optimising 7T-fMRI for imaging regions of magnetic susceptibility

The temporal signal-to-noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B0 and B1+ magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T-fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi-echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi-echo increased the magnitude of the BOLD signal change, but only multi-echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi-echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi-echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi-echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.

neuroscience↗

Neurochemical markers of uncertainty processing in humans

How individuals process and respond to uncertainty has important implications for cognition and mental health. Here we use computational phenotyping to examine individualised "uncertainty fingerprints" in relation to neurometabolites and trait anxiety in humans. We introduce a novel categorical state-transition extension of the Hierarchical Gaussian Filter (HGF) to capture implicit learning in a four-choice probabilistic sensorimotor reversal learning task by tracking beliefs about stimulus transitions. Using 7-Tesla Magnetic Resonance Spectroscopy, we measured baseline neurotransmitter levels in the primary motor cortex (M1). Model-based results revealed dynamic belief updating in response to environmental changes. We further found region-specific relationships between M1 glutamate+ glutamine levels and prediction errors and volatility beliefs, revealing an important neural marker of probabilistic reversal learning in humans. High trait anxiety was associated with faster post-reversal responses. By integrating computational modelling with neurochemical assessments, this study provides novel insights into the neurocomputations that drive individual differences in processing uncertainty.

neuroscience↗

Dynamic parallel transmit diffusion MRI at 7T

Diffusion MRI (dMRI) is inherently limited by SNR. Scanning at 7T increases intrinsic SNR but 7T MRI scans suffer from regions of signal dropout, especially in the temporal lobes and cerebellum. We applied dynamic parallel transmit (pTx) to allow whole-brain 7T dMRI and compared with circularly polarized (CP) pulses in 6 subjects. Subject-specific 2-spoke dynamic pTx pulses were designed offline for 8 slabs covering the brain. We used vendor-provided B0 and B1+ mapping. Spokes positions were set using the Fourier difference approach, and RF coefficients optimized with a Jacobi-matrix high-flip-angle optimizer. Diffusion data were analyzed with FSL. Comparing whole-brain averages for pTx against CP scans: mean flip angle error improved by 15% for excitation (2-spoke-VERSE 15.7{degrees} vs CP 18.4{degrees}, P=0.012) and improved by 14% for refocusing (2-spoke-VERSE 39.7{degrees} vs CP 46.2{degrees}, P=0.008). Computed spin-echo signal standard deviation improved by 14% (2-spoke-VERSE 0.185 vs 0.214 CP, P=0.025). Temporal SNR increased by 5.4% (2-spoke-VERSE 8.47 vs CP 8.04, P=0.004) especially in the inferior temporal lobes. Diffusion fitting uncertainty decreased by 6.2% for first fibres (2-spoke VERSE 0.0655 vs CP 0.0703, P<0.001) and 1.3% for second fibers (2-spoke VERSE 0.139 vs CP 0.141, P=0.01). In conclusion, dynamic parallel transmit improves the uniformity of 7T diffusion-weighted imaging. In future, less restrictive SAR limits for parallel transmit scans are expected to allow further improvements.

neuroscience↗

Path integration selectively predicts midlife risk of Alzheimer's disease

The entorhinal cortex (EC) is the first cortical region to exhibit neurodegeneration in Alzheimers disease (AD), associated with EC grid cell dysfunction. Given the role of grid cells in path integration, we predicted that path integration impairment would represent the first behavioural change in adults at-risk of AD. Using immersive virtual reality, we found that midlife path integration impairments predicted both hereditary and physiological AD risk, with no corresponding impairment on tests of episodic memory or other spatial behaviours. Impairments related to poorer angular estimation and were associated with hexadirectional grid-like fMRI signal in the posterior-medial EC. These results indicate that altered path integration may represent the transition point from at-risk state to disease onset in AD, prior to impairment in other cognitive domains.

neuroscience↗

Water-Only Look-Locker Inversion recovery (WOLLI) T1 mapping

PurposeModified Look-Locker Inversion recovery (MOLLI) and Shortened MOLLI (ShMOLLI) T1 values can deviate substantially from the water T1 in voxels containing large amounts of water and fat. We introduce Water-Only Look-Locker Inversion recovery (WOLLI) to map water T1 in tissue containing fat. TheoryWOLLI comprises adiabatic water-selective inversion and several balanced steady-state free precession (bSSFP) readouts, followed immediately by adiabatic fat-selective inversion and bSSFP readout(s). Data are fitted pixel-wise and an adapted Deichmann-Haase saturation-correction gives the water T1. MethodsWe compared two WOLLI protocols (WOLLI-w7f1 and WOLLI-w7f2f1), ShMOLLI and single-voxel spectroscopy at 3T in: simulations, fat/water phantoms, and 12 subjects livers. ResultsIn simulations with 0-40% fat fraction, T1 varied by: <0.5% (WOLLI-w7f1), <12% (WOLLI-w7f2f1), and >100% (MOLLI). In phantoms, the accuracy of the methods (i.e. worst-case T1w difference vs spectroscopy) was: WOLLI-w7f1 (best, maximum difference of 10.2%), WOLLI-w7f2f1 (max. 10.5%), and ShMOLLI (max. 81.5%). In the liver, the root-mean-squared deviations vs spectroscopy were: 374ms (WOLLI-w7f1), 645ms (WOLLI-w7f2f1), and 700ms (ShMOLLI). ConclusionCompared to ShMOLLI, WOLLI is less influenced by fat, but more by B0-inhomogeneity. WOLLI was a clear improvement in phantoms but less so in vivo. WOLLI may be suited to scan organs with high fat content such as the liver.

biophysics↗

21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)

A 3D density-weighted concentric ring trajectory (CRT) MRSI sequence is implemented for cardiac 31P-MRS at 7T. The point-by-point k-space sampling of traditional phase-encoded CSI sequences severely restricts the minimum scan time at higher spatial resolutions. Our proposed CRT sequence implements a stack of concentric rings trajectory, with a variable number of rings and planes spaced to optimise the density of k-space weighting. This creates flexibility in acquisition time, allowing acquisitions substantially faster than traditional phase-encoded CSI sequences, while retaining high SNR. We first characterise the signal-to-noise ratio and point spread function of the CRT sequence in phantoms. We then evaluate it at five different acquisition times and spatial resolutions in the hearts of five healthy participants at 7T. These different sequence durations are compared with existing published 3D acquisition-weighted CSI sequences with matched acquisition times and spatial resolutions. To minimise the effect of noise on the short acquisitions, low-rank denoising of the spatio-temporal data was also performed after acquisition. The proposed sequence measures 3D localised PCr/ATP ratios of the human myocardium in 2.5 minutes, 2.6 times faster than the minimum scan time for the acquisition-weighted phase-encoded CSI. Alternatively, in the same scan time a 1.7-times smaller nominal voxel volume can be achieved. Low-rank denoising reduced the variance of measured PCr/ATP ratios by 11% across all protocols. The faster acquisitions permitted by 7T CRT 31P-MRSI could make cardiac stress protocols or creatine kinase rate measurements (which involve repeated scans) more tolerable for patients without sacrificing spatial resolution.

physiology↗

Correcting for Superficial Bias in 7T Gradient Echo fMRI

1The arrival of submillimetre ultra high-field fMRI makes it possible to compare activation profiles across cortical layers. However, the Blood Oxygenation Level Dependent (BOLD) signal measured by Gradient-Echo fMRI is biased towards superficial layers of the cortex, which is a serious confound for laminar analysis. Several univariate and multivariate analysis methods have been proposed to correct this bias. We compare these methods using computational simulations and example human 7T fMRI data from Regions-of-Interest (ROIs) during a visual attention paradigm. The simulations show that two methods - the ratio of ROI means across conditions and a novel application of Deming regression - offer the most robust correction for superficial bias. Deming regression has the additional advantage that it does not require that the conditions differ in their mean activation over voxels within an ROI. When applied to the example dataset, these methods suggest that attentional modulation of activation is similar across cortical layers within the ventral visual stream, despite a naive activation-based analysis producing stronger modulation in superficial layers. Our study demonstrates that accurate correction of superficial bias is crucial to avoid drawing erroneous conclusions from laminar analyses of Gradient-Echo fMRI data.

neuroscience↗

Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study

We present the reliability of ultra-high field T2* MRI at 7T, as part of the UK7T Networks "Travelling Heads" study. T2*-weighted MRI images can be processed to produce quantitative susceptibility maps (QSM) and R2* maps. These reflect iron and myelin concentrations, which are altered in many pathophysiological processes. The relaxation parameters of human brain tissue are such that R2* mapping and QSM show particularly strong gains in contrast-to-noise ratio at ultra-high field (7T) vs clinical field strengths (1.5 - 3T). We aimed to determine the inter-subject and inter-site reproducibility of QSM and R2* mapping at 7T, in readiness for future multi-site clinical studies. MethodsTen healthy volunteers were scanned with harmonised single- and multi-echo T2*-weighted gradient echo pulse sequences. Participants were scanned five times at each "home" site and once at each of four other sites. The five sites had 1x Philips, 2x Siemens Magnetom, and 2x Siemens Terra scanners. QSM and R2* maps were computed with the Multi-Scale Dipole Inversion (MSDI) algorithm (https://github.com/fil-physics/Publication-Code). Results were assessed in relevant subcortical and cortical regions of interest (ROIs) defined manually or by the MNI152 standard space. Results and DiscussionMean susceptibility ({chi}) and R2* values agreed broadly with literature values in all ROIs. The inter-site within-subject standard deviation was 0.001 - 0.005 ppm ({chi}) and 0.0005 - 0.001 ms-1 (R2*). For {chi} this is 2.1-4.8 fold better than 3T reports, and 1.1-3.4 fold better for R2*. The median ICC from within- and cross-site R2* data was 0.98 and 0.91, respectively. Multi-echo QSM had greater variability vs single-echo QSM especially in areas with large B0 inhomogeneity such as the inferior frontal cortex. Across sites, R2* values were more consistent than QSM in subcortical structures due to differences in B0-shimming. On a between-subject level, our measured {chi} and R2* cross-site variance is comparable to within-site variance in the literature, suggesting that it is reasonable to pool data across sites using our harmonised protocol. ConclusionThe harmonized UK7T protocol and pipeline delivers on average a 3-fold improvement in the coefficient of reproducibility for QSM and R2* at 7T compared to previous reports of multi-site reproducibility at 3T. These protocols are ready for use in multi-site clinical studies at 7T.

neuroscience↗