Search bioRxiv⌕ Search

Biology subjects

Robertson, A. D.

Publications and source records attributed to Robertson, A. D..

4 recordsLinked to original sources

Assessing jugular venous compliance with optical hemodynamic imaging by modulating intrathoracic pressure

SignificanceThe internal jugular veins are critical cerebral venous drainage pathways that are affected by right heart function. Cardiovascular disease and microgravity can alter central venous pressure (CVP) and venous return, which may contribute to increased intracranial pressure and decreased cardiac output. Assessing jugular venous compliance may provide insight into cerebral drainage and right heart function, but monitoring changes in vessel volume is challenging. AimWe investigated the feasibility of quantifying jugular venous compliance from jugular venous attenuation (JVA), a non-contact optical measurement of blood volume, alongside CVP from antecubital vein cannulation. ApproachCVP was progressively increased through a guided graded Valsalva maneuver, increasing mouth pressure by 2 mmHg every 2 s until a maximum expiratory pressure of 20 mmHg. JVA was extracted from a 1 cm segment between the clavicle and mid-neck. Contralateral internal jugular vein cross-sectional area (CSA) was measured with ultrasound to validate changes in vessel size. Compliance was calculated using both JVA and CSA between four-beat averages over the duration of the maneuver. ResultsJVA and CSA were strongly correlated (median, interquartile range) over the Valsalva maneuver across participants (r=0.986, [0.983, 0.987]). CVP more than doubled on average between baseline and peak strain (10.7 {+/-} 4.4 vs 25.8 {+/-} 5.4 cmH2O; p<.01). JVA and CSA increased non-linearly with CVP, and both JVA- and CSA-derived compliance decreased progressively from baseline to peak strain (49% and 56% median reduction, respectively), with no significant difference in compliance reduction between the two measures (Z=-1.24, p=.21). Pressure-volume curves showed a logarithmic relationship in both CSA and JVA. ConclusionsOptical jugular vein assessment may provide new ways to assess jugular distention and cardiac function.

bioengineering↗

Chronic stroke sensorimotor impairment is related to smaller hippocampal volumes: An ENIGMA analysis

Persistent sensorimotor impairments after stroke can negatively impact quality of life. The hippocampus is involved in sensorimotor behavior but has not been widely studied within the context of post-stroke upper limb sensorimotor impairment. The hippocampus is vulnerable to secondary degeneration after stroke, and damage to this region could further weaken sensorimotor circuits, leading to greater chronic sensorimotor impairment. The purpose of this study was to investigate the cross-sectional association between non-lesioned hippocampal volume and upper limb sensorimotor impairment in people with chronic stroke. We hypothesized that smaller ipsilesional hippocampal volumes would be associated with worse upper-limb sensorimotor impairment. Cross-sectional T1-weighted brain MRIs were pooled from 357 participants at the chronic stage after stroke (>180 days post-stroke) compiled from 18 research cohorts worldwide in the ENIGMA Stroke Recovery Working Group (age: median = 61 years, interquartile range = 18, range = 23-93; 135 women and 222 men). Sensorimotor impairment was estimated from the Fugl-Meyer Assessment of Upper Extremity scores. Robust mixed-effects linear models were used to test associations between post-stroke sensorimotor impairment and hippocampal volumes (ipsilesional and contralesional separately; Bonferroni-corrected, p-value < 0.025), controlling for age, sex, lesion volume, and lesioned hemisphere. We also performed an exploratory analysis to test whether sex differences influence the relationship between sensorimotor impairment and hippocampal volume. Upper limb sensorimotor impairment was positively associated with ipsilesional (p = 0.005; d = 0.33) but not contralesional (p = 0.96; d = 0.01) hippocampal volume, such that impairment was worse for participants with smaller ipsilesional hippocampal volume. This association remained significant independent of lesion volume or other covariates (p = 0.001; d = 0.36). Evidence indicates an interaction between sensorimotor impairment and sex for both ipsilesional (p = 0.008; d = -0.29) and contralesional (p = 0.006; d = -0.30) hippocampal volumes, whereby women showed progressively worsening sensorimotor impairment with smaller hippocampal volumes compared to men. The present study has identified a novel association between chronic post-stroke sensorimotor impairment and ipsilesional, but not contralesional, hippocampal volume. This finding was not due to lesion size and may be stronger in women. We also provide supporting evidence that smaller hippocampal volume post-stroke is likely a consequence of ipsilesional damage, which could provide a link between vascular disease and other disorders, such as dementia.

neuroscience↗

ExploreASL: an image processing pipeline for multi-center ASL perfusion MRI studies

Arterial spin labeling (ASL) has undergone significant development since its inception, with a focus on improving standardization and reproducibility of its acquisition and quantification. In a community-wide effort towards robust and reproducible clinical ASL image processing, we developed the software package ExploreASL, allowing standardized analyses across centers and scanners. The procedures used in ExploreASL capitalize on published image processing advancements and address the challenges of multi-center datasets with scanner-specific processing and artifact reduction to limit patient exclusion. ExploreASL is self-contained, written in MATLAB and based on Statistical Parameter Mapping (SPM) and runs on multiple operating systems. The toolbox adheres to previously defined international standards for data structure, provenance, and best analysis practice. ExploreASL was iteratively refined and tested in the analysis of >10,000 ASL scans using different pulse-sequences in a variety of clinical populations, resulting in four processing modules: Import, Structural, ASL, and Population that perform tasks, respectively, for data curation, structural and ASL image processing and quality control, and finally preparing the results for statistical analyses on both single-subject and group level. We illustrate ExploreASL processing results from three cohorts: perinatally HIV-infected children, healthy adults, and elderly at risk for neurodegenerative disease. We show the reproducibility for each cohort when processed at different centers with different operating systems and MATLAB versions, and its effects on the quantification of gray matter cerebral blood flow. ExploreASL facilitates the standardization of image processing and quality control, allowing the pooling of cohorts to increase statistical power and discover between-group perfusion differences. Ultimately, this workflow may advance ASL for wider adoption in clinical studies, trials, and practice.

neuroscience↗

Development and validation of a 36-gene sequencing assay for hereditary cancer risk assessment

The past two decades have brought many important advances in our understanding of the hereditary susceptibility to cancer. Numerous studies have provided convincing evidence that identification of germline mutations associated with hereditary cancer syndromes can lead to reductions in morbidity and mortality through targeted risk management options. Additionally, advances in gene sequencing technology now permit the development of multigene hereditary cancer testing panels. Here, we describe the 2016 revision of the Counsyl Inherited Cancer Screen for detecting single-nucleotide variants (SNVs), short insertions and deletions (indels), and copy number variants (CNVs) in 36 genes associated with an elevated risk for breast, ovarian, colorectal, gastric, endometrial, pancreatic, thyroid, prostate, melanoma, and neuroendocrine cancers. To determine test accuracy and reproducibility, we performed a rigorous analytical validation across 341 samples, including 118 cell lines and 223 patient samples. The screen achieved 100% test sensitivity across different mutation types, with high specificity and 100% concordance with conventional Sanger sequencing and multiplex ligation-dependent probe amplification (MLPA). We also demonstrated the screens high intra-run and inter-run reproducibility and robust performance on blood and saliva specimens. Furthermore, we showed that pathogenic Alu element insertions can be accurately detected by our test. Overall, the validation in our clinical laboratory demonstrated the analytical performance required for collecting and reporting genetic information related to risk of developing hereditary cancers.

genetics↗