Search bioRxiv⌕ Search

Biology subjects

Riedel, T. E.

Publications and source records attributed to Riedel, T. E..

4 recordsLinked to original sources

Fieldable isothermal nucleic acid test for rapid semi-quantitative visual readout of Enterococci in recreational waters

Enterococci are fecal indicator bacteria whose presence in water suggests the potential for gastrointestinal pathogens. Culture-based detection is slow and may require expensive apparatus and proprietary media. Molecular tests based on qPCR can be technically difficult and require complex devices. Loop-mediated isothermal amplification (LAMP) tests that need minimal instrumentation have been described but they only qualitatively indicate presence or absence of Enterococci, which is difficult to compare with quantitative contamination standards for assessing water quality. Here, we demonstrate semi-quantitative thresholded LAMP that uses internal competition with pre-defined false targets and an oligonucleotide strand displacement (OSD) probe to measure the degree of Enterococcus contamination in water. The assay needs only one hour of incubation at a single temperature following which a simple visual examination of endpoint OSD fluorescence allows order of magnitude scale estimation of Enterococcus amounts. Environmental water samples with low, medium, and high Enterococcus contamination could be readily distinguished by thresholded LAMP-OSD without interference from non-specific signals. LAMP-OSD performance correlated with the outcomes of both qPCR and plate cultures of the samples. The simplicity of implementing thresholded LAMP-OSD makes it well suited for point-of-need and low-cost water quality monitoring.

molecular biology↗

Novel Loop-Mediated Isothermal Amplification via One Step Strand Displacement Diagnostic of Spotted Fevers

1.Spotted fever rickettsiosis plagues countries around the world. One of the deadliest of this group, Rickettsia rickettsii, responsible for Rocky Mountain spotted fever, is an emerging tickborne illness in North America. The predominant clinical diagnostic is PCR based but does not work until disease has progressed to a severe phase of infection, at which point the outcome of a full recovery is significantly decreased. An alternative, loop mediated isothermal amplification through one-step strand displacement (LAMP-OSD) assay, was developed to improve diagnostic speed and sensitivity. Synthetic dsDNA genes from the 17 kDa surface antigen precursor (AY281069.1) amplified between fifteen minutes to an hour and were detected to concentrations as low as 102 copies/L. This RMSF LAMP-OSD assay shows promise to deliver results in just a few hours and the detection limit is potentially 100 times more sensitive than qPCR based assays.

microbiology↗

High-surety isothermal amplification and detection of SARS-CoV-2, including with crude enzymes

ABSTRACTIsothermal nucleic acid amplification tests (iNAT), such as loop-mediated isothermal amplification (LAMP), are good alternatives to polymerase chain reaction (PCR)-based amplification assays, especially for point-of-care and low resource use, in part because they can be carried out with relatively simple instrumentation. However, iNATs can generate spurious amplicons, especially in the absence of target sequences, resulting in false positive results. This is especially true if signals are based on non-sequence-specific probes, such as intercalating dyes or pH changes. In addition, pathogens often prove to be moving, evolving targets, and can accumulate mutations that will lead to inefficient primer binding and thus false negative results. Internally redundant assays targeting different regions of the target sequence can help to reduce such false negatives. Here we describe rapid conversion of three previously described SARS-CoV-2 LAMP assays that relied on non-sequence-specific readout into assays that can be visually read using sequence-specific fluorogenic oligonucleotide strand exchange (OSD) probes. We evaluate one-pot operation of both individual and multiplex LAMP-OSD assays and demonstrate detection of SARS-CoV-2 virions in crude human saliva.Competing Interest StatementThe authors have declared no competing interest.View Full Text

molecular biology↗

Direct nucleic acid analysis of mosquitoes for high fidelity species identification and detection of Wolbachia using a cellphone

Manipulation of natural mosquito populations using the endosymbiotic bacteria Wolbachia is being investigated as a novel strategy to reduce the burden of mosquito-borne viruses. To evaluate the efficacy of these interventions, it will be critical to determine Wolbachia infection frequencies in Aedes aegypti mosquito populations. However, current diagnostic tools are not well-suited to fit this need. Morphological methods cannot identify Wolbachia, immunoassays often suffer from low sensitivity and poor throughput, while PCR and spectroscopy require complex instruments and technical expertise, which restrict their use to centralized laboratories. To address this unmet need, we have used loop-mediated isothermal amplification (LAMP) and oligonucleotide strand displacement (OSD) probes to create a one-pot sample-to-answer nucleic acid diagnostic platform for vector and symbiont surveillance. LAMP-OSD assays can directly amplify target nucleic acids from macerated mosquitoes without requiring nucleic acid purification and yield specific single endpoint yes/no fluorescence signals that are observable to eye or by cellphone camera. We demonstrate cellphone-imaged LAMP-OSD tests for two targets, the Aedes aegypti cytochrome oxidase I (coi) gene and the Wolbachia surface protein (wsp) gene, and show a limit of detection of 4 and 40 target DNA copies, respectively. In a blinded test of 90 field-caught mosquitoes, the coi LAMP-OSD assay demonstrated 98% specificity and 97% sensitivity in identifying Ae. aegypti mosquitoes even after 3 weeks of storage without desiccant at 37 {degrees}C. Similarly, the wsp LAMP-OSD assay readily identified the wAlbB Wolbachia strain in field-collected Aedes albopictus mosquitoes without generating any false positive signals. Modest technology requirements, minimal execution steps, simple binary readout, and robust accuracy make the LAMP-OSD-to-cellphone assay platform well suited for field vector surveillance in austere or resource-limited conditions.\n\nAuthor summaryMosquitoes spread many human pathogens and novel approaches are required to reduce the burden of mosquito-borne disease. One promising approach is transferring Wolbachia into Aedes aegypti mosquitoes where it blocks transmission of arboviruses like dengue, Zika and Yellow fever viruses and spreads through mosquito populations. For effective evaluation of this approach, regular surveillance of Wolbachia infections in Ae. aegypti is required, but current diagnostic tools are not well suited to support these critical surveillance needs. To fill this need we developed a simple, robust and inexpensive assay to identify Ae. aegypti mosquitoes and Wolbachia using our unique one-pot assay platform, LAMP-OSD, which uses loop-mediated isothermal amplification to amplify nucleic acid targets at a single temperature. Unlike other LAMP-based tests, our assays assure accuracy by coupling amplification with novel nucleic acid strand displacement (OSD) probes that hybridize to specific sequences in LAMP amplification products and thereby generate simple yes/no readout of fluorescence readable by human eye and by off-the-shelf cellphones. To facilitate field use, we developed our assays so they are compatible with crushed mosquito homogenate as the template, meaning no nucleic acid extraction is required. In blinded tests using field collected mosquitoes, LAMP-OSD-cellphone tests performed robustly to identify 29 of 30 Ae. aegypti even after 3 weeks of storage at 37 {degrees}C while producing only one false positive out of 60 non-specific mosquitoes. Similarly, our assay could identify Wolbachia in field-caught Aedes albopictus without producing any false positives. Our easy to use and easy to interpret assays should facilitate widespread field mosquito surveillance with minimal instrumentation and high accuracy.

molecular biology↗