Search bioRxiv⌕ Search

Biology subjects

Rice, W. J.

Publications and source records attributed to Rice, W. J..

9 recordsLinked to original sources

Structures of the human sodium-citrate cotransporter NaCT with and without substrates

The human sodium-citrate cotransporter NaCT imports various tri- and dicarboxylates into the cell as TCA cycle intermediates. This substrate uptake process is driven by an inward sodium gradient. The protein is a member of the Divalent Anion-Sodium Symporter (DASS) family. Whereas extensive biochemical and structural studies have been carried out for NaCT, how the substrate binding and translocation is coupled to the sodium gradient remains unclear. Here using single particle cryo-electron microscopy, we determined the structures of the human NaCT protein in three states: sodium-free, in the presence of sodium, and sodium- and substrate-bound. These structures suggest a simultaneous binding mechanism for sodium-substrate coupling, distinct from the sequential binding, conformational selection mechanism previously observed for the bacterial DASS protein VcINDY.

biophysics↗

Structures of the T cell potassium channel Kv1.3 with immunoglobulin modulators

The Kv1.3 potassium channel is expressed abundantly on activated T cells and mediates the cellular immune response. This role has made the channel a target for therapeutic immunomodulation to block its activity and suppress T cell activation. We determined structures of human Kv1.3 alone, with a nanobody inhibitor, and with an antibody-toxin fusion blocker. Rather than block the channel directly, four copies of the nanobody bind the tetramers voltage sensing domains and the pore domain to induce an inactive pore conformation. In contrast, the antibody-toxin fusion docks its toxin domain at the extracellular mouth of the channel to insert a critical lysine into the pore. The lysine induces an active conformation of the pore yet blocks ion permeation. This study visualizes Kv1.3 pore dynamics, defines two distinct mechanisms to suppress Kv1.3 channel activity with exogenous inhibitors, and provides a framework to aid development of emerging T cell immunotherapies.

biophysics↗

ACE2-containing defensosomes serve as decoys to inhibit SARS-CoV-2 infection

Extracellular vesicles of endosomal origin, exosomes, mediate intercellular communication by transporting substrates with a variety of functions related to tissue homeostasis and disease. Their diagnostic and therapeutic potential has been recognized for diseases such as cancer in which signaling defects are prominent. However, it is unclear to what extent exosomes and their cargo inform the progression of infectious diseases. We recently defined a subset of exosomes termed defensosomes that are mobilized during bacterial infection in a manner dependent on autophagy proteins. Through incorporating protein receptors on their surface, defensosomes mediated host defense by binding and inhibiting pore-forming toxins secreted by bacterial pathogens. Given this capacity to serve as decoys that interfere with surface protein interactions, we investigated the role of defensosomes during infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the etiological agent of COVID-19. Consistent with a protective function, exosomes containing high levels of the viral receptor ACE2 in bronchioalveolar lavage fluid from critically ill COVID-19 patients was associated with reduced ICU and hospitalization times. We found ACE2+ exosomes were induced by SARS-CoV-2 infection and activation of viral sensors in cell culture, which required the autophagy protein ATG16L1, defining these as defensosomes. We further demonstrate that ACE2+ defensosomes directly bind and block viral entry. These findings suggest that defensosomes may contribute to the antiviral response against SARS-CoV-2 and expand our knowledge on the regulation and effects of extracellular vesicles during infection.

immunology↗

The impact of data reduction and lossy image formats on electron microscope images

Recent advances in instrumentation and software for cryoEM have increased the applicability and utility of this method. Coupled with the adoption of automated pipelines, significant infrastructure support is required to sustain high throughput workflows. In particular, data generation rates may outpace the ability to deploy data storage and archival solutions. We have investigated what effects data compression and conversion to different file formats have on the ability to obtain high resolution cryoEM reconstructions. Standard lossless data compression strategies have a high impact on reducing the size of direct detector electron counting movie stacks, but provide more modest gains for aligned summed images. We show that EM images can be compressed using standard lossy methods to reduce file storage to 5-10% of the size of the original aligned sum or movie stack file and yet still retain enough information such that modern image processing pipelines will provide sub-2[A] reconstructions from the compressed data.

biophysics↗

Benchmarking cryo-EM single particle analysis workflow

Cryo electron microscopy facilities running multiple instruments and serving users with varying skill levels need a robust and reliable method for benchmarking both the hardware and software components of their single particle analysis workflow. The workflow is complex, with many bottlenecks existing at the specimen preparation, data collection and image analysis steps; the samples and grid preparation can be of unpredictable quality, there are many different protocols for microscope and camera settings, and there is a myriad of software programs for analysis that can depend on dozens of settings chosen by the user. For this reason, we believe it is important to benchmark the entire workflow, using a standard sample and standard operating procedures, on a regular basis. This provides confidence that all aspects of the pipeline are capable of producing maps to high resolution. Here we describe benchmarking procedures using a test sample, rabbit muscle aldolase.

molecular biology↗

High Resolution Single Particle Cryo-Electron Microscopy using Beam-Image Shift

Automated data acquisition is now used widely for the single-particle averaging approach to reconstruction of three-dimensional (3D) volumes of biological complexes preserved in vitreous ice and imaged in a transmission electron microscope (cryo-EM). Automation has become integral to this method because of the very large number of particle images required to be averaged in order to overcome the typically low signal-to-noise ratio of these images.\n\nFor optimal efficiency, all automated data acquisition software packages employ some degree of beam-image shift because this method is fast and accurate (+/- 0.1 m). Relocation to a targeted area under low-dose conditions can only be achieved using stage movements in combination with multiple iterations or long relaxation times, both reducing efficiency. It is, however, well known that applying beam-image shift induces beam-tilt and hence structure phase error. A {pi}/4 phase error is considered as the worst that can be accepted, and is used as an argument against the use of any beam-image shift for high resolution data collection.\n\nIn this study, we performed cryo-EM single-particle reconstructions on a T20S proteasome sample using applied beam-image shifts corresponding to beam tilts from 0 to 10 mrad. To evaluate the results we compared the FSC values, and examined the water density peaks in the 3D map. We conclude that the {pi}/4 phase error does not limit the validity of the 3D reconstruction from single-particle averaging beyond the {pi}/4 resolution limit.

biophysics↗

Routine Determination of Ice Thickness for Cryo-EM Grids

Recent advances in instrumentation and automation have made cryo-EM a popular method for producing near-atomic resolution structures of a variety of proteins and complexes. Sample preparation is still a limiting factor in collecting high quality data. Thickness of the vitreous ice in which the particles are embedded is one of the many variables that need to be optimized for collection of the highest quality data. Here we present two methods, using either an energy filter or scattering outside the objective aperture, to measure ice thickness for potentially every image collected. Unlike geometrical or tomographic methods, these can be implemented directly in the single particle collection workflow without interrupting or significantly slowing down data collection. We describe the methods as implemented into the Leginon/Appion data collection workflow, along with some examples from test cases. Routine monitoring of ice thickness should prove helpful for optimizing sample preparation, data collection, and data processing.

biophysics↗

Spotiton: New Features and Applications

We present an update describing new features and applications of Spotiton, a novel instrument for vitrifying samples for cryoEM. We have used Spotiton to prepare several test specimens that can be reconstructed using routine single particle analysis to ~3 [A] resolution, indicating that the process has no apparent deleterious effect on the sample integrity. The system is now in routine and continuous use in our lab and has been used to successfully vitrify a wide variety of samples.

molecular biology↗

Routine Single Particle CryoEM Sample and Grid Characterization by Tomography

Single particle cryo-electron microscopy (cryoEM) is often performed under the assumption that particles are freely floating away from the air-water interfaces and in thin, vitreous ice. In this study, we performed fiducial-less tomography on over 50 different cryoEM grid/sample preparations to determine the particle distribution within the ice and the overall geometry of the ice in grid holes. Surprisingly, by studying particles in holes in 3D from over 1,000 tomograms, we have determined that the vast majority of particles (approximately 90%) are adsorbed to an air-water interface. The implications of this observation are wide-ranging, with potential ramifications regarding protein denaturation, conformational change, and preferred orientation. We also show that fiducial-less cryo-electron tomography on single particle grids may be used to determine ice thickness, optimal single particle collection areas and strategies, particle heterogeneity, and de novo models for template picking and single particle alignment.

biophysics↗