Search bioRxiv⌕ Search

Biology subjects

Rea, M.

Publications and source records attributed to Rea, M..

7 recordsLinked to original sources

Measuring the neurodevelopmental trajectory of excitatory-inhibitory balance via visual gamma oscillations

Disruption of the balance between excitatory and inhibitory neurotransmission (E-I balance) underlies theories of many neurodevelopmental disorders, however, its study is typically restricted to adults, animal models and the lab-bench. Neurophysiological oscillations in the gamma frequency band relate closely to E-I balance, and a new technology - OPM-MEG - offers the possibility to measure such signals across the lifespan. We used OPM-MEG to measure gamma oscillations induced by visual stimulation in >100 participants, aged 2-34 years. We demonstrate a significantly changing spectrum with age, with low amplitude broadband gamma oscillations in children and high amplitude band limited oscillations dominating in adults. We used a canonical cortical microcircuit to model these gamma signals, revealing significant age-related shifts in E-I balance in superficial pyramidal neurons in visual cortex. Our findings detail the first MEG metrics of gamma oscillations and their underlying generators from toddlerhood, providing a benchmark against which future studies can contextualise.

neuroscience↗

A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers

Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; however, the field has been revolutionised in recent years by the introduction of optically-pumped-magnetometers (OPMs). OPMs enable measurement of the MEG signal without cryogenics, and consequently the conception of OPM-MEG systems which ostensibly allow increased sensitivity and resolution, lifespan compliance, free subject movement, and lower cost. However, OPM-MEG remains in its infancy with limitations on both sensor and system design. Here, we report a new OPM-MEG design with miniaturised and integrated electronic control, a high level of portability, and improved sensor dynamic range (arguably the biggest limitation of existing instrumentation). We show that this system produces equivalent measures when compared to an established instrument; specifically, when measuring task-induced beta-band, gamma-band and evoked neuro-electrical responses, source localisations from the two systems were highly comparable and temporal correlation was >0.7 at the individual level and >0.9 for groups. Using an electromagnetic phantom, we demonstrate improved dynamic range by running the system in background fields up to 8 nT. We show that the system is effective in gathering data during free movement (including a sitting-to-standing paradigm) and that it is compatible with simultaneous electroencephalography (EEG - the clinical standard). Finally, we demonstrate portability by moving the system between two laboratories. Overall, our new system is shown to be a significant step forward for OPM-MEG technology and offers an attractive platform for next generation functional medical imaging.

neuroscience↗

Loss of Linker Histone H1 in the Maternal Genome Influences DEMETER-Mediated Demethylation and Affects the Endosperm DNA Methylation Landscape

The Arabidopsis DEMETER (DME) DNA glycosylase demethylates the central cell genome prior to fertilization. This epigenetic reconfiguration of the female gamete companion cell establishes gene imprinting in the endosperm and is essential for seed viability. DME demethylates small and genic-flanking transposons as well as intergenic and heterochromatin sequences, but how DME is recruited to these target loci remains unknown. H1.2 was identified as a DME-interacting protein in a yeast two-hybrid screen, and maternal genome H1 loss affects DNA methylation and expression of selected imprinted genes in the endosperm. Yet, the extent to which how H1 influences DME demethylation and gene imprinting in the Arabidopsis endosperm has not been investigated. Here, we showed that unlike in the vegetative cell, both canonical histone H1 variants are present in the central cell. Our endosperm methylome analysis revealed that without the maternal linker histones, DME-mediated demethylation is facilitated, particularly in the heterochromatin regions, indicating that H1-containing nucleosomes are barriers for DME demethylation. Loss of H1 in the maternal genome has a very limited effect on gene transcription or gene imprinting regulation in the endosperm; however, it variably influences euchromatin TE methylation and causes a slight hypermethylation and a reduced expression in selected imprinted genes. We conclude that loss of maternal H1 indirectly influences DME-mediated demethylation and endosperm DNA methylation landscape but does not appear to affect endosperm gene transcription and overall imprinting regulation.

plant biology↗

Naturalistic hyperscanning with wearable magnetoencephalography

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction. However, present technologies are limited, either by poor performance (low spatial/temporal precision) or unnatural scanning environment (claustrophobic scanners, with interactions via video). Here, we solve this problem by developing a new form of hyperscanning using wearable magnetoencephalography (MEG). This approach exploits quantum sensors for MEG signal detection, in combination with high-fidelity magnetic field control - afforded by a novel "matrix coil" system - to enable simultaneous scanning of two freely moving participants. We demonstrate our approach in a somatosensory task and an interactive ball game. Despite large and unpredictable subject motion, sensorimotor brain activity was delineated clearly in space and time, and correlation of the envelope of neuronal oscillations between people was demonstrated. In sum, unlike existing modalities, wearable-MEG combines high fidelity data acquisition and a naturalistic setting, which will facilitate a new generation of hyperscanning.

neuroscience↗

Magnetic Field Mapping and Correction for Moving OP-MEG

BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.

neuroscience↗

Measuring functional connectivity with wearable MEG

Optically-pumped magnetometers (OPMs) offer the potential for a step change in magnetoencephalography (MEG) enabling wearable systems that: provide improved data quality; accommodate any subject group; allow data capture during movement and offer a reduction in costs. However, OPM-MEG is still a nascent technology and, to realise its potential, it must be shown to facilitate key neuroscientific measurements, such as the characterisation of human brain networks. Networks, and the connectivities that underlie them, have become a core area of neuroscientific investigation, and their importance is underscored by many demonstrations of their perturbation in brain disorders. Consequently, a demonstration of network measurements via OPM-MEG would be a significant step forward. Here, we aimed to show that a wearable 50-channel OPM-MEG system enables characterisation of the electrophysiological connectome. To this end, we characterise connectivity in the resting state and during a simple visuo-motor task, using both OPM-MEG and a state-of-the-art 275-channel cryogenic MEG device. Our results show that connectome matrices from OPM and cryogenic systems exhibit an extremely high degree of similarity, with correlation values >70 %. This value is not measurably different to the correlation observed between connectomes measured in different subject groups, on a single scanner. In addition, similar differences in connectivity between individuals (scanned multiple times) were observed in cryogenic and OPM-MEG data, again demonstrating the fidelity of OPM-MEG data. This demonstration shows that a nascent OPM-MEG system offers results similar to a cryogenic device, even despite having [~]5 times fewer sensors. This adds weight to the argument that OPMs will ultimately supersede cryogenic sensors for MEG measurement.

neuroscience↗

Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System

Magnetoencephalography (MEG) is a powerful technique for functional neuroimaging, offering a non-invasive window on brain electrophysiology. MEG systems have traditionally been based on cryogenic sensors which detect the small extracranial magnetic fields generated by synchronised current in neuronal assemblies, however such systems have fundamental limitations. In recent years quantum-enabled devices, called optically-pumped magnetometers (OPMs), have promised to lift those restrictions, offering an adaptable, motion-robust MEG device, with improved data quality, at reduced cost. However, OPM-MEG remains a nascent technology, and whilst viable systems exist, most employ small numbers of sensors sited above targeted brain regions. Here, building on previous work, we construct a wearable OPM-MEG system with whole-head coverage based upon commercially available OPMs, and test its capabilities to measure alpha, beta and gamma oscillations. We design two methods for OPM mounting; a flexible (EEG-like) cap and rigid (additively-manufactured) helmet. Whilst both designs allow for high quality data to be collected, we argue that the rigid helmet offers a more robust option with significant advantages for reconstruction of field data into 3D images of changes in neuronal current. Using repeat measurements in two participants, we show signal detection for our device to be highly robust. Moreover, via application of source-space modelling, we show that, despite having 5 times fewer sensors, our system exhibits comparable performance to an established cryogenic MEG device. While significant challenges still remain, these developments provide further evidence that OPM-MEG is likely to facilitate a step change for functional neuroimaging. HIGHLIGHTSO_LIA 49-channel whole-head OPM-MEG system is constructed C_LIO_LISystem evaluated via repeat measurements of alpha, beta and gamma oscillations C_LIO_LITwo OPM-helmet designs are contrasted, a flexible (EEG-like) cap and a rigid helmet C_LIO_LIThe rigid helmet offers significant advantages for a viable OPM-MEG device C_LIO_LI49-channel OPM-MEG offers performance comparable to established cryogenic devices C_LI

neuroscience↗