Search bioRxiv⌕ Search

Biology subjects

Ramos-Torres, K. M.

Publications and source records attributed to Ramos-Torres, K. M..

5 recordsLinked to original sources

Imaging traumatic brain injuries in mice with potassium channel PET tracer 3F4AP

ObjectiveTraumatic brain injury (TBI) can lead to secondary injury, including axon and myelin damage, which contributes to long-term neurological deficits. The PET tracer [18F]3F4AP, a fluorinated derivative of the FDA-approved drug 4-aminopyridine, selectively binds to voltage-gated potassium (KV) channels, offering a novel approach to assess TBI-related node of Ranvier disruption and demyelination. This study evaluates [18F]3F4AP PET in penetrating and non-penetrating TBI models. MethodsEither controlled cortical impact (CCI, penetrating) or concussive (non-penetrating) TBI models were used to induce TBI in mice. Dynamic PET imaging with [18F]3F4AP was performed at time points of 0, 3, 7, 14, and/or 31 days post-injury (dpi), with quantitative analyses comparing tracer uptake in injured versus control regions. Luxol fast blue (LFB) staining was conducted to evaluate histological myelin loss. ResultsIn the CCI model, [18F]3F4AP PET imaging demonstrated a 34% increase in tracer uptake at the injury site at 7 dpi, correlating with histological evidence of demyelination. Tracer uptake gradually declined over time, reflecting potential remyelination. The concussive TBI model showed a smaller and more diffuse increase in uptake at 7 dpi compared to CCI. Conclusion[18F]3F4AP PET imaging effectively detects demyelination following TBI, with very high sensitivity in penetrating injuries. These findings highlight the potential of [18F]3F4AP as a valuable imaging biomarker for assessing TBI progression and/or therapeutic response. Further studies are warranted to explore its clinical applicability and comparison with other imaging modalities.

neuroscience↗

Synthesis of K+ channel radioligand 5-methyl-3-fluoro-4-aminopyridine and PET imaging in mice

Abstract and Graphical abstract[18F]3-fluoro-4-aminopyridine ([18F]3F4AP) is the first positron emission tomography (PET) radioligand that targets voltage-gated potassium (K+) channels in the brain for imaging demyelination. [18F]3F4AP exhibits high brain penetration, favorable kinetics for PET imaging, and high sensitivity to demyelinating lesions. However, recent studies in awake human subjects indicate lower metabolic stability than in anesthetized animals, resulting in reduced brain uptake. Therefore, there is a need for novel radioligands for K+ channels with suitable pharmacological properties and enhanced metabolic stability. Recent in vitro studies demonstrate that 5-methyl-3-fluoro-4-aminopyridine (5Me3F4AP) exhibits comparable binding affinity to K+ channels, pKa, logD, and membrane permeability as 3F4AP, and a slower enzymatic metabolic rate, suggesting its potential as a K+ channel PET tracer. In this study, we describe the radiochemical synthesis of [18F]5Me3F4AP using an isotope exchange method from the corresponding 3-fluoro-5-methyl-4-nitropyridine N-oxide, followed by a palladium on carbon mediated hydrogenation of the nitro and N-oxide groups. This method yielded [18F]5Me3F4AP with high purity and acceptable molar activity. PET/CT studies using naive mice demonstrate that [18F]5Me3F4AP effectively crosses the blood-brain barrier and has comparable kinetics to [18F]3F4AP. These findings strongly suggest that [18F]5Me3F4AP is a promising candidate for neuroimaging applications and warrant further studies to investigate its sensitivity to lesions and in vivo metabolic stability. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=192 SRC="FIGDIR/small/604281v1_ufig1.gif" ALT="Figure 1"> View larger version (44K): org.highwire.dtl.DTLVardef@1b2af88org.highwire.dtl.DTLVardef@223de1org.highwire.dtl.DTLVardef@c9a8borg.highwire.dtl.DTLVardef@1761cba_HPS_FORMAT_FIGEXP M_FIG C_FIG

biochemistry↗

Imaging demyelinated axons after spinal cord injuries with PET tracer 3F4AP

Spinal cord injuries (SCI) often lead to lifelong disability. Among the various types of injuries, incomplete and discomplete injuries, where some axons remain intact, offer potential for recovery. However, demyelination of these spared axons can worsen disability. Demyelination is a reversible phenomenon, and drugs like 4-aminopyridine (4AP), which target K+ channels in demyelinated axons, show that conduction can be restored. Yet, accurately assessing and monitoring demyelination post-SCI remains challenging due to the lack of suitable imaging methods. In this study, we introduce a novel approach utilizing the positron emission tomography (PET) tracer, [18F]3F4AP, specifically targeting K+ channels in demyelinated axons for SCI imaging. Rats with incomplete contusion injuries were imaged up to one month post-injury, revealing [18F]3F4APs exceptional sensitivity to injury and its ability to detect temporal changes. Further validation through autoradiography and immunohistochemistry confirmed [18F]3F4APs targeting of demyelinated axons. In a proof-of-concept study involving human subjects, [18F]3F4AP differentiated between a severe and a largely recovered incomplete injury, indicating axonal loss and demyelination, respectively. Moreover, alterations in tracer delivery were evident on dynamic PET images, suggestive of differences in spinal cord blood flow between the injuries. In conclusion, [18F]3F4AP demonstrates efficacy in detecting incomplete SCI in both animal models and humans. The potential for monitoring post-SCI demyelination changes and response to therapy underscores the utility of [18F]3F4AP in advancing our understanding and management of spinal cord injuries.

neuroscience↗

Common anesthetic used in preclinical PET imaging inhibits metabolism of the PET tracer 3F4AP

PET imaging studies in laboratory animals are almost always performed under isoflurane anesthesia to ensure that the subject stays still during the image acquisition. Isoflurane is effective, safe, and easy to use, and it is generally assumed to not have an impact on the imaging results. Motivated by marked differences observed in [18F]3F4AP brain uptake and metabolism between human and nonhuman primate studies, this study investigates the possible effect of isoflurane on [18F]3F4AP metabolism and brain uptake. Isoflurane was found to largely abolish tracer metabolism in mice resulting in a 3.3-fold higher brain uptake in anesthetized mice at 35 min post radiotracer administration, which replicated the observed effect in unanesthetized humans and anesthetized monkeys. This effect is attributed to isofluranes interference in the CYP2E1-mediated breakdown of [18F]3F4AP, which was confirmed by reproducing a higher brain uptake and metabolic stability upon treatment with the known CYP2E1 inhibitor disulfiram. These findings underscore the critical need to examine the effect of isoflurane in PET imaging studies before translating tracers to humans that will be scanned without anesthesia.

neuroscience↗

Structure-activity relationship studies of three novel 4-aminopyridine K+ channel blockers

4-Aminopyridine (4AP) is a specific blocker of voltage-gated potassium channels (KV1 family) clinically approved for the symptomatic treatment of patients with multiple sclerosis (MS). It has recently been shown that [18F]3F4AP, a radiofluorinated analog of 4AP, also binds to KV1 channels and can be used as a PET tracer for the detection of demyelinated lesions in rodent models of MS. Here, we investigate three novel 4AP derivatives containing methyl (-CH3), methoxy (-OCH3) and trifluoromethyl (-CF3) in the 3 position as potential candidates for PET imaging and/or therapy. We characterized the physicochemical properties of these compounds (pKa and logD) and analyzed their ability to block Shaker K+ channel under different voltage and pH conditions. Our results demonstrate that all three derivatives are able to block voltage-gated potassium channels. Specifically, 3-methyl-4-aminopyridine (3Me4AP) was found to be approximately 7-fold more potent than 4AP, whereas the methoxy (3MeO4AP) and trifluoromethyl (3CF34AP) containing compounds were about 3- to 4-fold less potent than 4AP, respectively. These results suggest that these novel derivatives are potential candidates for therapy and imaging.

biophysics↗