Search bioRxiv⌕ Search

Biology subjects

Radosevich, A. J.

Publications and source records attributed to Radosevich, A. J..

4 recordsLinked to original sources

In-vitro Modeling of Intravenous Drug Precipitation by the Optical Spatial Precipitation Analyzer (OSPREY)

Intravenous (IV) administration of poorly water-soluble small molecule therapeutics can lead to precipitation during mixing with blood. This can limit characterization of pharmacological and safety endpoints in preclinical models. Most often, tests of kinetic and thermodynamic solubility are used to optimize the formulation for solubility prior to infusion in animals, but these do not capture the dynamic precipitation processes that take place during in-vivo administration. To better capture the fluid dynamic processes that occur during IV administration, we developed the Optical Spatial Precipitation AnalYzer (OSPREY) as a method to quantify the amount and size of compound precipitates in whole blood using a flow-through system that mimics IV administration. Here, we describe the OSPREY device and its underlying imaging processing methods. We then validate the ability to accurately segment particles according to their size using monodisperse suspensions of microspheres (diameter 50 to 425 microns). Next, we use a tool compound, ABT-737, to study the effects of compound concentration, vessel flow rate, compound infusion rate and vessel diameter on precipitation. Finally, we use the physiological diameter and flow rate of rat femoral vein and dog saphenous vein to demonstrate the potential of OSPREY to model in-vivo precipitation in a controlled, dynamic in-vitro assay. HighlightsO_LIProspective small molecule therapeutics are often solubility challenged when injected into whole blood at elevated concentrations for toxicology studies. C_LIO_LIImproved in-vitro solubility measurements in a flowing system are needed to better understand in-vivo intravenous precipitation C_LIO_LIOSPREY is a novel in-vitro flow-through system that quantifies solubility in whole blood C_LI Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=88 SRC="FIGDIR/small/530827v1_ufig1.gif" ALT="Figure 1"> View larger version (29K): org.highwire.dtl.DTLVardef@15b28b4org.highwire.dtl.DTLVardef@1cd4845org.highwire.dtl.DTLVardef@43d919org.highwire.dtl.DTLVardef@61f978_HPS_FORMAT_FIGEXP M_FIG C_FIG

pharmacology and toxicology↗

A New Platform for Label-Free, Proximal Cellular Pharmacodynamic Assays: Identification of Glutaminase Inhibitors Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry

Cellular pharmacodynamic assays are crucial aspects of lead optimization programs in drug discovery. These assays are sometimes difficult to develop, oftentimes distal from the target and frequently low throughput which necessitates their incorporation in the drug discovery funnel later than desired. The earlier direct pharmacodynamic modulation of a target can be established, the less resources are wasted on compounds that are acting via an off-target mechanism. Mass spectrometry is a versatile tool that is often used for direct, proximal cellular pharmacodynamic assay analysis but liquid chromatography-mass spectrometry methods are low throughput and unable to fully support structure-activity relationships efforts in early medicinal chemistry programs. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization method amenable to high throughput cellular assays, capable of diverse analyte detection, ambient and rapid laser sampling process, and low cross contamination. Here we demonstrate the capability of IR-MALDESI for detection of diverse analytes directly from cells and report the development of a high throughput label free, proximal cellular pharmacodynamic assay using IR-MALDESI for discovery of glutaminase inhibitors and a biochemical assay for hit confirmation. We demonstrate the throughput with a [~]100,000 compound cellular screen. Hits from the screening were confirmed by retesting in dose-response with mass spectrometry-based cellular and biochemical assays. A similar workflow can be applied to other targets with minimal modifications, which will speed up discovery of cell active lead series and minimize wasted chemistry resources on off-target mechanisms.

biochemistry↗

High Throughput Intact Protein Analysis Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry

Mass spectrometry (MS) is the primary analytical tool used to characterize proteins within the biopharmaceutical industry. Electrospray ionization (ESI) coupled to liquid chromatography (LC) is the current gold standard for intact protein analysis. However, inherent speed limitations of LC/MS prevent analysis of large sample numbers (>1000) in a day. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI-MS), an ambient ionization MS technology, has recently been established as a platform for high throughput small molecule analysis. Here we report the applications of such a system for the analysis of intact proteins commonly performed within the drug discovery process. A wide molecular weight range of proteins 10 - 150 kDa was detected on the system with improved tolerance to salts and buffers compared to ESI. With high concentrations and model proteins, a sample rate up to 22 Hz was obtained. For proteins at low concentrations and in buffers used in commonly employed assays, robust data at a sample rate of 1.5 Hz was achieved, which is [~] 22x faster than current technologies used for high throughput ESI-MS-based protein assays. In addition, two multiplexed plate-based high throughput sample cleanup methods were coupled to IR-MALDESI-MS to enable analysis of samples containing excessive amounts of salts and buffers without fully compromising productivity. Example experiments, which leverage the speed of the IR-MALDESI-MS system to monitor NISTmAb reduction, protein autophosphorylation and compound binding kinetics in near real-time, are demonstrated. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=71 SRC="FIGDIR/small/467755v3_ufig1.gif" ALT="Figure 1"> View larger version (13K): org.highwire.dtl.DTLVardef@afa091org.highwire.dtl.DTLVardef@56b6ecorg.highwire.dtl.DTLVardef@1034f83org.highwire.dtl.DTLVardef@5949fb_HPS_FORMAT_FIGEXP M_FIG C_FIG

biochemistry↗

Ultrahigh-Throughput Direct Sampling MS: Sampling at 22 Hz by Infrared Matrix-Assisted Desorption Electrospray Ionization Mass Spectrometry

Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI) mass spectrometry is an ambient-direct sampling method being developed for high-throughput, label-free, biochemical screening of large-scale compound libraries. Here, we report the development of an ultrahigh-throughput continuous motion IR-MALDESI sampling approach capable of acquiring data at rates up to 22.7 samples per second in a 384-well microtiter plate. At top speed, less than 1% analyte carryover is observed from well-to-well and signal intensity relative standard deviations (RSD) of 11.5% and 20.9% for 3 M 1-hydroxymidazolam and 12 M dextrorphan, respectively, are achieved. The ability to perform parallel kinetics studies on 384 samples with ~30s time resolution using an isocitrate dehydrogenase 1 (IDH1) enzyme assay is shown. Finally, we demonstrate the repeatability and throughput of our approach by measuring 115,200 samples from 300 microtiter plate reads consecutively over 5.54 hours with RSDs under 8.14% for each freshly introduced plate. Taken together, these results demonstrate the use of IR-MALDESI at sample acquisition rates that surpass other currently reported direct sampling mass spectrometry approaches used for high throughput compound screening. For Table of Contents Only O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=125 SRC="FIGDIR/small/465730v3_ufig1.gif" ALT="Figure 1"> View larger version (49K): org.highwire.dtl.DTLVardef@5f916corg.highwire.dtl.DTLVardef@4473b4org.highwire.dtl.DTLVardef@82e8forg.highwire.dtl.DTLVardef@128b57b_HPS_FORMAT_FIGEXP M_FIG C_FIG

pharmacology and toxicology↗