Search bioRxiv⌕ Search

Biology subjects

Qiang, Y.

Publications and source records attributed to Qiang, Y..

9 recordsLinked to original sources

Single-cell analysis of the somatic mutational landscape in human chondrocytes during aging and in osteoarthritis

Somatic mutation is now recognized as a cause of multiple human diseases other than cancer. Osteoarthritis (OA), a highly prevalent age-related disease, has been associated with increased chromosomal abnormalities in articular cartilage of OA patients. Thus far no systematic attempt has been made to characterize the somatic mutational landscape of chondrocytes during normal aging and in affected cartilage of OA patients. Here we used single-cell whole genome sequencing to quantitatively analyze single-nucleotide variants (SNVs) and small insertions and deletions (InDels) in 100 single chondrocytes isolated from the cartilage of hip femoral heads of 17 subjects aged from 26 to 90 years, including 9 OA patients and 8 non-OA donors. Both SNVs and InDels were found to accumulate with age in chondrocytes with a clock-like mutational signature. Surprisingly, the age-related accumulation rate of these mutations was found to be lower in OA chondrocytes compared with chondrocytes from non-OA control subjects.

genomics↗

Red blood cell passage through deformable interendothelial slits in the spleen: Insights into splenic filtration and hemodynamics

The spleen constantly clears altered red blood cells (RBCs) from the circulation, tuning the balance between RBC formation (erythropoiesis) and removal. The retention and elimination of RBCs occur predominantly in the open circulation of the spleen, where RBCs must cross submicron-wide inter-endothelial slits (IES). Several experimental and computational studies have illustrated the role of IES in filtrating the biomechanically and morphologically altered RBCs based on a rigid wall assumption. However, these studies also reported that when the size of IES is close to the lower end of clinically observed sizes (less than 0.5 m), an unphysiologically large pressure difference across the IES is required to drive the passage of normal RBCs, sparking debates on the feasibility of the rigid wall assumption. In this work, we perform a computational investigation based on dissipative particle dynamics (DPD) to explore the impact of the deformability of IES on the filtration function of the spleen. We simulate two deformable IES models, namely the passive model and the active model. In the passive model, we implement the worm-like string model to depict the IESs deformation as it interacts with blood plasma and allows RBC to traverse. In contrast, the active model involved regulating the IES deformation based on the local pressure surrounding the slit. To demonstrate the validity of the deformable model, we simulate the filtration of RBCs with varied size and stiffness by IES under three scenarios: 1) a single RBC traversing a single slit; 2) a suspension of RBCs traversing an array of slits, mimicking in vitro spleen-on-a-chip experiments; 3) RBC suspension passing through the 3D spleen filtration unit known as the splenon. Our simulation results of RBC passing through a single slit show that the deformable IES model offers more accurate predictions of the critical cell surface area to volume ratio that dictate the removal of aged RBCs from circulation compared to prior rigid-wall models. Our biophysical models of the spleen-on-a-chip indicates a hierarchy of filtration function stringency: rigid model > passive model > active model, providing a possible explanation of why the spleen-on-a-chip could overestimate the filtration function of IES. We also illustrate that the biophysical model of the splenon enables us to replicate the ex vivo experiments involving spleen filtration of malaria-infected RBCs. Taken together, our simulation findings indicate that the deformable IES model could serve as a mesoscopic representation of spleen filtration function closer to physiological reality, addressing questions beyond the scope of current experimental and computational models and enhancing our understanding of the fundamental flow dynamics and mechanical clearance processes within in the human spleen.

bioengineering↗

Early evolution of the ecdysozoan body plan

Extant ecdysozoans (moulting animals) are represented by a great variety of vermiform or articulated organisms. However, controversies remain about the nature of their ancestral body plan although the vermiform hypothesis seems to prevail. We describe here Beretella spinosa gen et sp. nov. a tiny ecdysozoan from the early Cambrian, Yanjiahe Formation, South China, with an unusual sack-like appearance, single opening, and spiny ornament. Beretella has no equivalent among animals, except Saccorhytus from the basal Cambrian. Phylogenetic analyses resolve both forms as a sister group (Saccorhytida) to all known Ecdysozoa, thus suggesting that ancestral ecdysozoans may have been non-vermiform animals. Saccorhytids are likely to represent an early dead-end off-shot along the stem-line Ecdysozoa that possibly evolved through anatomical simplification (e.g. lack of anus). Although extinct during the Cambrian, this animal lineage provides precious insight into the early evolution of Ecdysozoa and the nature (possibly non-vermiform) of the earliest representatives of the group.

paleontology↗

Long-Term In Vivo Molecular Monitoring Using Aptamer-Graphene Microtransistors

Long-term, real-time molecular monitoring in complex biological environments is critical for our ability to understand, prevent, diagnose, and manage human diseases. Aptamer-based electrochemical biosensors possess the promise due to their generalizability and a high degree of selectivity. Nevertheless, the operation of existing aptamer-based biosensors in vivo is limited to a few hours. Here, we report a first-generation long-term in vivo molecular monitoring platform, named aptamer-graphene microtransistors (AGMs). The AGM incorporates a layer of pyrene- (polyethylene glycol)5-alcohol and DNase inhibitor-doped polyacrylamide hydrogel coating to reduce biofouling and aptamer degradation. As a demonstration of function and generalizability, the AGM achieves the detection of biomolecules such as dopamine and serotonin in undiluted whole blood at 37 {degrees}C for 11 days. Furthermore, the AGM successfully captures optically evoked dopamine release in vivo in mice for over one week and demonstrates the capability to monitor behaviorally-induced endogenous dopamine release even after eight days of implantation in freely moving mice. The results reported in this work establish the potential for chronic aptamer-based molecular monitoring platforms, and thus serve as a new benchmark for molecular monitoring using aptamer-based technology.

bioengineering↗

A combined computational and experimental investigation of the filtration function of splenic macrophages in sickle cell disease

Being the largest lymphatic organ in the body, the spleen also constantly controls the quality of red blood cells (RBCs) in circulation through its two major filtration components, namely interendothelial slits (IES) and red pulp macrophages. In contrast to the extensive studies in understanding the filtration function of IES, there are relatively fewer works on investigating how the splenic macrophages retain the aged and diseased RBCs, i.e., RBCs in sickle cell disease (SCD). Herein, we perform a computational study informed by companion experiments to quantify the dynamics of RBCs captured and retained by the macrophages. We first calibrate the parameters in the computational model based on microfluidic experimental measurements for sickle RBCs under normoxia and hypoxia, as those parameters are not available in the literature. Next, we quantify the impact of a set of key factors that are expected to dictate the RBC retention by the macrophages in the spleen, namely, blood flow conditions, RBC aggregation, hematocrit, RBC morphology, and oxygen levels. Our simulation results show that hypoxic conditions could enhance the adhesion between the sickle RBCs and macrophages. This, in turn, increases the retention of RBCs by as much as five-fold, which could be a possible cause of RBC congestion in the spleen of patients with SCD. Our study on the impact of RBC aggregation illustrates a clustering effect, where multiple RBCs in one aggregate can make contact and adhere to the macrophages, leading to a higher retention rate than that resulting from RBC-macrophage pair interactions. Our simulations of sickle RBCs flowing past macrophages for a range of blood flow velocities indicate that the increased blood velocity could quickly attenuate the function of the red pulp macrophages on detaining aged or diseased RBCs, thereby providing a possible rationale for the slow blood flow in the open circulation of the spleen. Furthermore, we quantify the impact of RBC morphology on their tendency to be retained by the macrophages. We find that the sickle and granular-shaped RBCs are more likely to be filtered by macrophages in the spleen. This finding is consistent with the observation of low percentages of these two forms of sickle RBCs in the blood smear of SCD patients. Taken together, our experimental and simulation results aid in our quantitative understanding of the function of splenic macrophages in retaining the diseased RBCs and provide an opportunity to combine such knowledge with the current knowledge of the interaction between IES and traversing RBCs to apprehend the complete filtration function of the spleen in SCD.

bioengineering↗

Temporal control of the integrated stress response by a stochastic molecular switch

Stress granules (SGs) are formed in the cytosol as an acute response to environmental cues and activation of the integrated stress response (ISR), a central signaling pathway controlling protein synthesis. Using chronic virus infection as stress model, we previously uncovered a unique temporal control of the ISR resulting in recurrent phases of SG assembly and disassembly. Here, we elucidate the molecular network generating this fluctuating stress response, by integrating quantitative experiments with mathematical modeling, and find that the ISR operates as a stochastic switch. Key elements controlling this switch are the cooperative activation of the stress-sensing kinase PKR, the ultrasensitive response of SG formation to the phosphorylation of the translation initiation factor eIF2, and negative feedback via GADD34, a stress-induced subunit of protein phosphatase 1. We identify GADD34 mRNA levels as the molecular memory of the ISR that plays a central role in cell adaptation to acute and chronic stress.

cell biology↗

A Probabilistic Approach For Registration Of Multi-Modal Spatial Transcriptomics Data

Observing the spatial characteristics of gene expression by image-based spatial transcriptomics technology allows studying gene activity across different cells and intracellular structures. We present a probabilistic approach for the registration and analysis of transcriptome images and immunostaining images. The method is based on particle filters and jointly exploits intensity information and image features. We applied our approach to synthetic data as well as real transcriptome images and immunostaining microscopy images of the mouse brain. It turns out that our approach accurately registers the multi-modal images and yields better results than a state-of-the-art method.

bioinformatics↗

Electrical impedance detection of sickle cell vaso-occlusion in microfluidic capillary structures

Sickle cell disease (SCD) is primarily associated with episodic vaso-occlusive events. Poorly deformable sickle cells may get stuck in small blood vessels, slow down or block blood flow, leading to local hypoxia that damages tissues and organs. In this paper, we present a novel electrical impedance sensing technique for detection of the progressive occlusion by sickle cells in microfluidic capillary structures. Changes in both resistance and reactance of the sickle blood flow were observed at multiple low frequencies (< 500 kHz), upon the deoxygenation and reoxygenation processes. In contrast, no obvious impedance changes were observed in the flow of normal blood cells and sickle blood cells treated with anti-sickling agent. Accuracy of the impedance-based detection of the vaso-occlusion process was verified by microscopic observation. The results show the distinct sensing performance of sickle cell vaso-occlusion by electrical impedance, which does not require sophisticated optical microscopy or video processing. The low frequency impedance sensing can be achieved by replacing the benchtop equipment with low-cost, high precision impedance converter system, allowing for detection of sickle cell vaso-occlusion in point-of-care settings.

bioengineering↗

A Portable Impedance Microflow Cytometer for Measuring Cellular Response to Hypoxia

This paper presents the development and testing of a low-cost, portable microflow cytometer based on electrical impedance sensing, for single cell analysis under controlled oxygen microenvironment. The cytometer system is based on an AD5933 impedance analyzer chip, a microfluidic chip, and an Arduino microcontroller operated by a custom Android application. A representative case study on human red blood cells (RBCs) affected by sickle cell disease is conducted to demonstrate the capability of the cytometry system. Equivalent circuit model of a suspending biological cell is used to interpret the electrical impedance of single flowing RBCs. In normal blood, cytoplasmic resistance and membrane capacitance do not change significantly with the change in oxygen tension. In contrast, RBCs affected by sickle cell disease show that upon hypoxia treatment, the cytoplasmic resistance decrease from 11.6 M{Omega} to 23.4 M{Omega}, and membrane capacitance decrease from 1.1 pF to 0.8 pF. Strong correlations are identified between the changes in these subcellular electrical components of single cells and the cell sickling process induced by hypoxia treatment. The representative results reported in this paper suggest that single cell electrical impedance can be used as a sensitive biophysical marker for quantifying cellular response to change in oxygen concentration. The developed flow cytometry system and the methodology can also be extended to analysis of cellular response to hypoxia in other cell types. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=124 SRC="FIGDIR/small/224006v1_ufig1.gif" ALT="Figure 1"> View larger version (38K): org.highwire.dtl.DTLVardef@147f903org.highwire.dtl.DTLVardef@2d4c35org.highwire.dtl.DTLVardef@1e63b0dorg.highwire.dtl.DTLVardef@2eeb0c_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗