Search bioRxivSearch

Biology subjects

Potter, C. S.

Publications and source records attributed to Potter, C. S..

6 recordsLinked to original sources

Complete functional mapping of infection- and vaccine-elicited antibodies against the fusion peptide of HIV

Eliciting broadly neutralizing antibodies (bnAbs) targeting envelope (Env) is a major goal of HIV vaccine development, but cross-clade breadth from immunization has only sporadically been observed. Recently, Xu et al (2018) elicited cross-reactive neutralizing antibody responses in a variety of animal models using immunogens based on the epitope of bnAb VRC34.01. The VRC34.01 antibody, which was elicited by natural human infection, targets the N terminus of the Env fusion peptide, a critical component of the virus entry machinery. Here we precisely characterize the functional epitopes of VRC34.01 and two vaccine-elicited murine antibodies by mapping all single amino-acid mutations to the BG505 Env that affect viral neutralization. While escape from VRC34.01 occurred via mutations in both fusion peptide and distal interacting sites of the Env trimer, escape from the vaccine-elicited antibodies was mediated predominantly by mutations in the fusion peptide. Cryo-electron microscopy of four vaccine-elicited antibodies in complex with Env trimer revealed focused recognition of the fusion peptide and provided a structural basis for development of neutralization breadth. Together, these functional and structural data suggest that the breadth of vaccine-elicited antibodies targeting the fusion peptide can be enhanced by specific interactions with additional portions of Env. Thus, our complete maps of viral escape provide a template to improve the breadth or potency of future vaccine-induced antibodies against Envs fusion peptide.\n\nAuthor summaryA major goal of HIV-1 vaccine design is to elicit antibodies that neutralize diverse strains of HIV-1. Recently, some of us elicited such antibodies in animal models using immunogens based on the epitope of a broad antibody (VRC34.01) isolated from an infected individual. Further improving these vaccine-elicited antibody responses will require a detailed understanding of how the resulting antibodies target HIVs envelope protein (Env). Here, we used mutational antigenic profiling to precisely map the epitope of two vaccine-elicited antibodies and the template VRC34.01 antibody. We did this by quantifying the effect of all possible amino acid mutations to Env on antibody neutralization. Although all antibodies target a similar region of Env, we found clear differences in the functional interaction of Env with the vaccine- and infection-elicited antibodies. We combined these functional data with structural analyses to identify antibody-Env interactions that could improve the breadth of vaccine-elicited antibodies, and thereby help to refine vaccination schemes to achieve broader responses.

immunology

High Resolution Single Particle Cryo-Electron Microscopy using Beam-Image Shift

Automated data acquisition is now used widely for the single-particle averaging approach to reconstruction of three-dimensional (3D) volumes of biological complexes preserved in vitreous ice and imaged in a transmission electron microscope (cryo-EM). Automation has become integral to this method because of the very large number of particle images required to be averaged in order to overcome the typically low signal-to-noise ratio of these images.\n\nFor optimal efficiency, all automated data acquisition software packages employ some degree of beam-image shift because this method is fast and accurate (+/- 0.1 m). Relocation to a targeted area under low-dose conditions can only be achieved using stage movements in combination with multiple iterations or long relaxation times, both reducing efficiency. It is, however, well known that applying beam-image shift induces beam-tilt and hence structure phase error. A {pi}/4 phase error is considered as the worst that can be accepted, and is used as an argument against the use of any beam-image shift for high resolution data collection.\n\nIn this study, we performed cryo-EM single-particle reconstructions on a T20S proteasome sample using applied beam-image shifts corresponding to beam tilts from 0 to 10 mrad. To evaluate the results we compared the FSC values, and examined the water density peaks in the 3D map. We conclude that the {pi}/4 phase error does not limit the validity of the 3D reconstruction from single-particle averaging beyond the {pi}/4 resolution limit.

biophysics

Routine Determination of Ice Thickness for Cryo-EM Grids

Recent advances in instrumentation and automation have made cryo-EM a popular method for producing near-atomic resolution structures of a variety of proteins and complexes. Sample preparation is still a limiting factor in collecting high quality data. Thickness of the vitreous ice in which the particles are embedded is one of the many variables that need to be optimized for collection of the highest quality data. Here we present two methods, using either an energy filter or scattering outside the objective aperture, to measure ice thickness for potentially every image collected. Unlike geometrical or tomographic methods, these can be implemented directly in the single particle collection workflow without interrupting or significantly slowing down data collection. We describe the methods as implemented into the Leginon/Appion data collection workflow, along with some examples from test cases. Routine monitoring of ice thickness should prove helpful for optimizing sample preparation, data collection, and data processing.

biophysics

Reducing effects of particle adsorption to the air-water interface in cryoEM

Most protein particles prepared in vitreous ice for single particle cryo-electron microscopy are adsorbed to air-water or substrate-water interfaces, potentially causing particles to adopt preferred orientations. Using the Spotiton robot and nanowire grids, we can significantly reduce air-water interface issues by decreasing the dwell time of particles in thin liquid films. We demonstrate this by using single particle cryoEM and cryoET on three biological samples.

biophysics

Spotiton: New Features and Applications

We present an update describing new features and applications of Spotiton, a novel instrument for vitrifying samples for cryoEM. We have used Spotiton to prepare several test specimens that can be reconstructed using routine single particle analysis to ~3 [A] resolution, indicating that the process has no apparent deleterious effect on the sample integrity. The system is now in routine and continuous use in our lab and has been used to successfully vitrify a wide variety of samples.

molecular biology

Routine Single Particle CryoEM Sample and Grid Characterization by Tomography

Single particle cryo-electron microscopy (cryoEM) is often performed under the assumption that particles are freely floating away from the air-water interfaces and in thin, vitreous ice. In this study, we performed fiducial-less tomography on over 50 different cryoEM grid/sample preparations to determine the particle distribution within the ice and the overall geometry of the ice in grid holes. Surprisingly, by studying particles in holes in 3D from over 1,000 tomograms, we have determined that the vast majority of particles (approximately 90%) are adsorbed to an air-water interface. The implications of this observation are wide-ranging, with potential ramifications regarding protein denaturation, conformational change, and preferred orientation. We also show that fiducial-less cryo-electron tomography on single particle grids may be used to determine ice thickness, optimal single particle collection areas and strategies, particle heterogeneity, and de novo models for template picking and single particle alignment.

biophysics