Search bioRxiv⌕ Search

Biology subjects

Post, A.

Publications and source records attributed to Post, A..

2 recordsLinked to original sources

Transcranial random noise stimulation of the primary visual cortex but not retina modulates visual contrast sensitivity.

Transcranial random noise stimulation (tRNS) has been shown to significantly improve visual perception. Previous studies demonstrated that tRNS delivered over cortical areas acutely enhances visual contrast detection of stimuli when tRNS intensity is optimized for the individual. However, it is currently unknown whether tRNS-induced signal enhancement could be achieved within different neural substrates along the retino-cortical pathway and whether the beneficial effect of optimal tRNS intensities can be reproduced across sessions. In 3 experimental sessions, we tested whether tRNS applied to the primary visual cortex (V1) and/or to the retina improves visual contrast detection. We first measured visual contrast detection threshold (VCT; N=24, 16 females) during tRNS delivery separately over V1 (no tRNS, 0.75, 1, 1.5mA) and over the retina (no tRNS, 0.1, 0.2, 0.3mA), determined the optimal tRNS intensities for each individual (ind-tRNS), and retested the effects of ind-tRNS within the sessions. We further investigated whether we could reproduce the ind-tRNS-induced modulation on a different session (N=19, 14 females). Finally, we tested whether the simultaneous application of ind-tRNS to the retina and V1 causes additive effects. We found that at the group level tRNS of 0.75mA decreases VCT compared to baseline when delivered to the V1. Beneficial effects of ind-tRNS could be replicated when retested within the same experimental session but not when retested in a separate session. Applying tRNS to the retina did not cause a systematic reduction of VCT, irrespective of whether the individually optimized intensity was considered or not. We also did not observe consistent additive effects of V1 and retina stimulation. Our findings demonstrate that V1 seems to be more sensitive than the retina to tRNS-induced modulation of visual contrast processing. Significance statementOur findings confirm previous evidence showing acute online benefits of tRNS of V1 on visual contrast detection in accordance with the stochastic resonance phenomenon. We further extend it, demonstrating that the optimal tRNS intensity varies among participants, but when individually tailored it can improve visual processing when re-tested within the experimental session. The tRNS-induced enhancement in visual sensitivity seems to be specific for cortical contrast processing as stimulation of the retina did not lead to systematic effects.

neuroscience↗

Towards prevention of re-entrant arrhythmias: Injectable hydrogel electrodes enable direct capture of previously inaccessible cardiac tissues

Re-entrant arrhythmias--the leading cause of sudden cardiac death--are caused by diseased myocardial tissue and consequent delayed myocardial conduction. Access to the coronary veins that cross the "culprit" scar regions where re-entry originates can provide improved pacing to these delayed regions, offering a novel opportunity to prevent ventricular arrhythmias and circumvent the need for painful defibrillation, risky cardiac ablation, or toxic and often ineffective antiarrhythmic medications. However, there are no pacing electrodes which are small or focal enough to navigate these tributaries. To address this need, we have developed an injectable conductive hydrogel that can fill the epicardial coronary veins and their mid-myocardial tributaries. When connected to a standard pacing lead, these injected hydrogels can be converted into flexible electrodes that directly pace the previously inaccessible mid-myocardial tissue. In our two-component system, hydrogel precursor solutions can be injected through a dual lumen catheter in a minimally invasive deployment strategy to provide direct access to the diseased regions with precision and ease. Mixing of the two solutions upon injection into the vein activates redox-initiated crosslinking of the gel for rapid in situ cure without an external stimulus. An ex vivo porcine model was used to identify the requisite viscosity and cure rate for gel retention and homogeneity. Ionic species added to the hydrogel precursor solutions conferred conductivity above target myocardium values that was retained after implantation. Successful in vivo deployment demonstrated that the hydrogel electrode filled the anterior interventricular vein with extension into the septal (mid-myocardial) venous tributaries to depths far more distal and refined than any current technologies allow. In addition to successful capture and pacing of the heart, analysis of surface ECG tracings revealed a novel pacing observation highly specific for and suggestive of capture of extensive swaths of septal myocardial tissue. This is the first report of an injectable electrode used to successfully pace the mid-myocardium and mimic physiologic conduction. Furthermore, in vivo cardiac electroanatomical mapping studies in an ablation scar model showed uniform capture along the hydrogel in the vessels as well as increased capture area compared to point pacing. Collectively, these findings demonstrate that this injectable hydrogel electrode can be deployed to scarred regions of the heart to provide a reliable pacing modality that most closely resembles native conduction with the potential to eliminate delayed myocardial conduction and associated re-entry. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=179 SRC="FIGDIR/small/467102v2_ufig1.gif" ALT="Figure 1"> View larger version (50K): org.highwire.dtl.DTLVardef@1577526org.highwire.dtl.DTLVardef@cc510dorg.highwire.dtl.DTLVardef@1dd426eorg.highwire.dtl.DTLVardef@1346aab_HPS_FORMAT_FIGEXP M_FIG C_FIG One Sentence SummaryInjectable hydrogel electrodes achieve pacing that mimics physiologic conduction by capturing midmyocardial tissue

bioengineering↗