Search bioRxiv⌕ Search

Biology subjects

Pohmann, R.

Publications and source records attributed to Pohmann, R..

3 recordsLinked to original sources

High spatiotemporal resolution radial encoding single vessel fMRI

High-field preclinical functional MRI (fMRI) has enabled the high spatial resolution mapping of vessel-specific hemodynamic responses, i.e. single-vessel fMRI. In contrast to investigating neuronal sources of the fMRI signal, single vessel fMRI focuses on elucidating its vascular origin, which can be readily implemented to identify vascular changes relevant to vascular dementia or cognitive impairment. However, the limited spatial and temporal resolution of fMRI has hindered hemodynamic mapping of intracortical microvessels. Here, we implemented the radial encoding MRI scheme to measure BOLD signals of individual vessels penetrating the rat somatosensory cortex. Radial encoding MRI is employed to map cortical activation with a focal field of view (FOV), allowing vessel-specific functional mapping with 50x50 {micro}m in-plane resolution at 1 to 2 Hz sampling rate. Besides detecting refined hemodynamic responses of intracortical micro-venules, the radial encoding-based single-vessel fMRI enables the differentiation of the intravascular and extravascular effects from the draining venules.

neuroscience↗

Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI

Laminar-specific functional magnetic resonance imaging (fMRI) has been widely used to study circuit-specific neuronal activity by mapping spatiotemporal fMRI response patterns across cortical layers. Hemodynamic responses reflect indirect neuronal activity given limit of spatial and temporal resolution. Previous gradient-echo based line-scanning fMRI (GELINE) method was proposed with high temporal (50 ms) and spatial (50 {micro}m) resolution to better characterize the fMRI onset time across cortical layers by employing 2 saturation RF pulses. However, the imperfect RF saturation performance led to poor boundary definition of the reduced region of interest (ROI) and aliasing problems outside of the ROI. Here, we propose (alpha)-180 spin-echo-based line-scanning fMRI (SELINE) method to resolve this issue by employing a refocusing 180{degrees} RF pulse perpendicular to the excitation slice. In contrast to GELINE signals peaked at the superficial layer, we detected varied peaks of laminar-specific BOLD signals across deeper cortical layers with the SELINE method, indicating the well-defined exclusion of the large drain-vein effect with the spin-echo sequence. Furthermore, we applied the SELINE method with 200 ms TR to sample the fast hemodynamic changes across cortical layers with a less draining vein effect. In summary, this SELINE method provides a novel acquisition scheme to identify microvascular-sensitive laminar-specific BOLD responses across cortical depth.

neuroscience↗

Single-vessel cerebral blood flow fMRI to map blood velocity by phase-contrast imaging

Current approaches to high-field fMRI provide two means to map hemodynamics at the level of single vessels in the brain. One is through changes in deoxyhemoglobin in venules, i.e., blood oxygenation level-dependent (BOLD) fMRI, while the second is through changes in arteriole diameter, i.e., cerebral blood volume (CBV) fMRI. Here we introduce cerebral blood flow (CBF)-fMRI, which uses high-resolution phase-contrast MRI to form velocity measurements of flow and demonstrate CBF-fMRI in single penetrating microvessels across rat parietal cortex. In contrast to the venule-dominated BOLD and arteriole-dominated CBV fMRI signal, the phase-contrast -based CBF signal changes are highly comparable from both arterioles and venules. Thus, we have developed a single-vessel fMRI platform to map the BOLD, CBV, and CBF from penetrating microvessels throughout the cortex. This high-resolution single-vessel fMRI mapping scheme not only enables the vessel-specific hemodynamic mapping in diseased animal models but also presents a translational potential to map vascular dementia in diseased or injured human brains with ultra-high field fMRI. SummaryWe established a high-resolution PC-based single-vessel velocity mapping method using the high field MRI. This PC-based micro-vessel velocity measurement enables the development of the single-vessel CBF-fMRI method. In particular, in contrast to the arteriole-dominated CBV and venule-dominated BOLD responses, the CBF-fMRI shows similar velocity changes in penetrating arterioles and venules in activated brain regions. Thus, we have built a noninvasive single-vessel fMRI mapping scheme for BOLD, CBV, and CBF hemodynamic parameter measurements in animals.

neuroscience↗