Search bioRxiv⌕ Search

Biology subjects

Plank, G.

Publications and source records attributed to Plank, G..

4 recordsLinked to original sources

A Cohort-Based Global Sensitivity Benchmark of MRI-Derived Whole-Heart Electromechanical Models in Healthy Hearts

Patient-specific four-chamber electromechanical models provide a physics-constrained framework for investigating whole-heart cardiac physiology and disease mechanisms. Identifying which model parameters impact whole-heart function is important for understanding cellular-, tissue-, and organ-scale determinants of cardiac performance and for calibrating patient-specific models. However, previous global sensitivity analyses of cardiac electromechanical models have typically been performed on a single heart, and systematic evaluation of how parameter influence compares across anatomically different subjects remains limited. We created four-chamber electromechanical models using cardiac MRI from five healthy subjects (n = 5). The models simulated atrial and ventricular cellular electrophysiology, calcium dynamics, and active contraction, with heterogeneous fibre orientation, transversely isotropic tissue mechanics, pericardial constraint, and a closed-loop cardiovascular system providing physiological boundary conditions. In total, 46 parameters described the integrated model. Using Gaussian process emulators, we performed multi-scale global sensitivity analysis to evaluate the relative contribution of model parameters to left and right atrial and ventricular function. Across all anatomies, the most influential parameters were systemic and pulmonary resistances, ventricular end-diastolic pressures, and the venous reference pressure, highlighting the dominant role of haemodynamic loading conditions in governing pressure- and volume-based outputs. A chamber-level analysis of atrioventricular coupling revealed a phase-dependent pattern. Atrial pressures were predominantly governed by global haemodynamic parameters (> 90% of total sensitivity), atrial filling volumes showed substantial ventricular influence ({approx}40-55% across anatomies), and atrial end-systolic volumes were primarily determined by intrinsic atrial parameters ({approx}60-65%). These patterns were consistent across subjects despite differences in anatomy. We show that, in healthy male subjects, inter-individual anatomical variation does not substantially change the ranking of dominant parameters. This work provides a repeatable modelling and sensitivity analysis framework and establishes a benchmark reference for whole-heart electromechanical modelling in healthy hearts. Author summaryComputational models of the heart can simulate cardiac physiology in unprecedented detail, but these models contain many parameters whose influence on predicted function is not fully understood. We built patient-specific four-chamber heart models from MRI scans of five healthy subjects and used statistical methods to systematically test how 46 model parameters affect simulated cardiac performance. Across all five subjects, we found that the haemodynamic loading parameters, including systemic and pulmonary vascular resistance, ventricular filling pressures, and the venous reference pressure, consistently had the greatest influence on the model outputs, regardless of differences in individual heart anatomy. This finding suggests that in healthy resting conditions, the boundary conditions of the cardiovascular system, rather than individual differences in heart geometry or electrical properties, are the primary drivers of whole-heart function. We also found a structured coupling pattern between the upper and lower heart chambers, where global haemodynamic parameters dominate atrial pressure regulation, ventricular mechanics shape atrial filling, and intrinsic atrial properties control atrial emptying. This work provides a benchmark dataset of five anatomically detailed heart models and a sensitivity analysis framework to guide calibration of future cardiac digital twin models.

systems biology↗

Patient-specific multi-physics simulations of fibrotic changes in left atrial tissue mechanics impact on hemodynamics

Stroke is a leading cause of death and disability worldwide. Atrial myopathy, including fibrosis, is associated with an increased risk of ischemic stroke, but the mechanisms underlying this association are poorly understood. Fibrosis modifies myocardial structure, impairing electrical propagation and tissue biomechanics, and creating stagnant flow regions where clots could form. Fibrosis can be mapped non-invasively using late gadolinium enhancement magnetic resonance imaging (LGE-MRI). However, fibrosis maps are not currently incorporated into stroke risk calculations or computational electro-mechano-fluidic models. We present multi-physics simulations of left atrial (LA) myocardial motion and hemodynamics using patient-specific anatomies and fibrotic maps from LGE-MRI. We modify tissue stiffness and active tension generation in fibrotic regions and investigate how these changes affect LA flow for different fibrotic burdens. We find that fibrotic regions and, to a lesser extent, non-fibrotic regions experience reduced myocardial strain, resulting in decreased LA emptying fraction consistent with clinical observations. Both fibrotic tissue stiffening and hypocontractility independently reduce LA function, but together, these two alterations cause more pronounced effects than either one alone. Fibrosis significantly alters flow patterns throughout the atrial chamber, and particularly, the filling and emptying jets of the left atrial appendage (LAA). The effects of fibrosis in LA flow are largely captured by the concomitant changes in LA emptying fraction except inside the LAA, where a multi-factorial behavior is observed. This work illustrates how high-fidelity, multi-physics models can be used to study thrombogenesis mechanisms in patient-specific anatomies, shedding light onto the links between atrial fibrosis and ischemic stroke. Key pointsO_LILeft atrial (LA) fibrosis is associated with arrhythmogenesis and increased risk of ischemic stroke; its extent and pattern can be quantified on a patient-specific basis using late gadolinium enhancement magnetic resonance imaging. C_LIO_LICurrent stroke risk prediction tools have limited personalization, and their accuracy could be improved by incorporating patient-specific information like fibrotic maps and hemodynamic patterns. C_LIO_LIWe present the first electro-mechano-fluidic multi-physics computational simulations of LA flow, including fibrosis and anatomies from medical imaging. C_LIO_LIMechanical changes in fibrotic tissue impair global LA motion, decreasing LA and left atrial appendage (LAA) emptying fractions, especially in subjects with higher fibrosis burdens. C_LIO_LIFibrotic-mediated LA motion impairment alters LA and LAA flow near the endocardium and the whole cavity, ultimately leading to more stagnant blood regions in the LAA. C_LI

bioengineering↗

Neural network emulation of the human ventricular cardiomyocyte action potential: a tool for more efficient computation in pharmacological studies

AbstractComputer models of the human ventricular cardiomyocyte action potential (AP) have reached a level of detail and maturity that has led to an increasing number of applications in the pharmaceutical sector. However, interfacing the models with experimental data can become a significant computational burden. To mitigate the computational burden, the present study introduces a neural network (NN) that emulates the AP for given maximum conductances of selected ion channels, pumps, and exchangers. Its applicability in pharmacological studies was tested on synthetic and experimental data. The NN emulator potentially enables massive speed-ups compared to regular simulations and the forward problem (find drugged AP for pharmacological parameters defined as scaling factors of control maximum conductances) on synthetic data could be solved with average root-mean-square errors (RMSE) of 0.47 mV in normal APs and of 14.5 mV in abnormal APs exhibiting early afterdepolarizations (72.5% of the emulated APs were alining with the abnormality, and the substantial majority of the remaining APs demonstrated pronounced proximity). This demonstrates not only very fast and mostly very accurate AP emulations but also the capability of accounting for discontinuities, a major advantage over existing emulation strategies. Furthermore, the inverse problem (find pharmacological parameters for control and drugged APs through optimization) on synthetic data could be solved with high accuracy shown by a maximum RMSE of 0.21 in the estimated pharmacological parameters. However, notable mismatches were observed between pharmacological parameters estimated from experimental data and distributions obtained from the Comprehensive in vitro Proarrhythmia Assay initiative. This reveals larger inaccuracies which can be attributed particularly to the fact that small tissue preparations were studied while the emulator was trained on single cardiomyocyte data. Overall, our study highlights the potential of NN emulators as powerful tool for an increased efficiency in future quantitative systems pharmacology studies.

cell biology↗

The openCARP Simulation Environment for Cardiac Electrophysiology

Background and ObjectiveCardiac electrophysiology is a medical specialty with a long and rich tradition of computational modeling. Nevertheless, no community standard for cardiac electrophysiology simulation software has evolved yet. Here, we present the openCARP simulation environment as one solution that could foster the needs of large parts of this community. Methods and ResultsopenCARP and the Python-based carputils framework allow developing and sharing simulation pipelines which automate in silico experiments including all modeling and simulation steps to increase reproducibility and productivity. The continuously expanding openCARP user community is supported by tailored infrastructure. Documentation and training material facilitate access to this complementary research tool for new users. After a brief historic review, this paper summarizes requirements for a high-usability electrophysiology simulator and describes how openCARP fulfills them. We introduce the openCARP modeling workflow in a multi-scale example of atrial fibrillation simulations on single cell, tissue, organ and body level and finally outline future development potential. ConclusionAs an open simulator, openCARP can advance the computational cardiac electrophysiology field by making state-of-the-art simulations accessible. In combination with the carputils framework, it offers a tailored software solution for the scientific community and contributes towards increasing use, transparency, standardization and reproducibility of in silico experiments.

bioinformatics↗