Search bioRxiv⌕ Search

Biology subjects

Patton, G. C.

Publications and source records attributed to Patton, G. C..

2 recordsLinked to original sources

The Omicron variant BQ.1* with mutations at positions 28,311 and 28,312 in the SARS-CoV-2 N gene have minimal impact on CDC N1 target detection

Ensuring COVID-19 testing remains accurate and reliable is of critical importance as the SARS-CoV-2 virus continues to evolve. Currently, a number of Omicron variants are dominating infection across the globe in including BQ.1 and XBB. Both variants and their sublineages (BQ.1* and XBB*) contain a 28,311 C/U mutation inherited from the original Omicron variant (BA.1). This mutation overlaps with a commonly used fluorescent probe for N gene detection in many Emergency Use Authorization (EUA) assays, as this target was originally established by the U.S. Centers for Disease Control and Prevention (CDC) in their EUA test for COVID-19 (2019-nCoV_N1). This C to U mutation was previously shown to have no impact on CDC N1 target detection. The rise of Omicron sublineages has increased the likelihood of additional point mutations occurring within the same assay target. A subpopulation of BQ.1* has an additional 28,312 C/U mutation within the CDC 2019_nCoV_N1 fluorescent probe in addition to the 28,311 C/U mutation. The double mutation could adversely affect the ability of diagnostic assays to detect the virus in patient samples and therefore it is important to verify the impacts of this additional mutation. Using in vitro transcribed (IVT) N gene RNA representing the wildtype (GenBank/GISAID ID MN908947.3) and Omicron BQ.1.1 variant (BQ.1, GISAID ID EPI_ISL_ 15155651), we evaluated the performance of two different amplification protocols, both of which include the CDC 2019-nCoV_N1 primer-probe set. Both assays successfully detected the mutant N gene sequence efficiently even at 10 copies of input, although the double mutation caused a 0.5[~]1 Cq delay on average when compared to the wild-type sequence. These data suggest that circulating BQ.1* lineage viruses with this double mutation likely have minimal impact on diagnostic assays that use the 2019-nCoV-N1 primer-probe.

biochemistry↗

Enhancing Colorimetric LAMP Amplification Speed and Sensitivity with Guanidine Chloride

Loop-mediated isothermal amplification (LAMP) is a versatile technique for detection of target DNA and RNA, enabling rapid molecular diagnostic assays with minimal equipment. The global SARS-CoV-2 pandemic has presented an urgent need for new and better diagnostic methods, with colorimetric LAMP utilized in numerous studies for SARS-CoV-2 detection. However, the sensitivity of colorimetric LAMP in early reports has been below that of the standard RT-qPCR tests, and we sought to improve performance. Here we report the use of guanidine hydrochloride and combined primer sets to increase speed and sensitivity in colorimetric LAMP, bringing this simple method up to the standards of sophisticated technique and enabling accurate and high-throughput diagnostics.

biochemistry↗