Search bioRxiv⌕ Search

Biology subjects

Oberste-Frielinghaus, J.

Publications and source records attributed to Oberste-Frielinghaus, J..

2 recordsLinked to original sources

The effect of data preprocessing on spike correlation analysis results

In recent years, an increasing number of large electrophysiological data sets have become publicly available, thereby providing researchers with the opportunity to analyze spike train data without conducting their own experiments. While this is undoubtedly a positive development, it increases the need for proper documentation on how the data were collected and what preprocessing was performed on the data, since interpreting analysis results in ignorance of these pieces of information can lead to wrong conclusions. An important preprocessing step is the removal of artifacts from the recordings. Electrophysiological recordings are particularly susceptible to electrical cross-talks between recording channels, resulting in artifact spikes that are coincident in multiple channels on the time scale of the data sampling rate, i.e., 1/30 ms in popular setups. The removal by signal whitening is only possible if also the raw sampled data are available, thus to eliminate this type of artifact is to remove all coincident spikes on the recording time scale to definitely avoid artifact spikes. However, given the lack of the "ground truth", this step has the potential to eliminate, in conjunction with the artifacts, components of the data that are pertinent to the research objective. In this study, we use a modified version of the Unitary Event Analysis and demonstrate that such preprocessing results in significantly lower correlations than expected by chance even on longer time scales. We also propose a method to correct for the bias introduced by this preprocessing. Thus, slight changes in the preprocessing have potentially strong impact on analysis results and methods need to consider these effects.

neuroscience↗

Detection and Removal of Hyper-synchronous Artifacts in Massively Parallel Spike Recordings

Contemporary electrophysiology experiments often involve massively parallel recordings of neuronal activity using multi-electrode arrays. While researchers have been aware of artifacts arising from electric cross-talk between channels in setups for such recordings, systematic and quantitative assessment of the effects of those artifacts on the data quality has never been reported. Here we present, based on examination of electrophysiology recordings from multiple laboratories, that multi-electrode recordings of spiking activity commonly contain extremely precise (at the data sampling resolution) spike coincidences far above the chance level. We derive, through modeling of the electric cross-talk, a systematic relation between the amount of such hyper-synchronous events (HSEs) in channel pairs and the correlation between the raw signals of those channels in the multi-unit activity frequency range (500-7500 Hz). We show that whitening the band-pass filtered raw signals removes the above chance HSEs; strongly suggesting they originate from linear mixing of signals. Whitening should therefore be performed prior to spike sorting and any further analysis of precise spike correlation, otherwise analysis results may be considerably affected. Significance StatementArtifacts are ubiquitous in electrophysiological recordings. To mitigate their impact, these artifacts need to be detected and they should be removed from the data without impacting the quality of the data. This work presents measures to identify and quantify the amount of artifacts within a multichannel recording by evaluating the occurrence of hyper-synchronous events i.e., spikes that are synchronous on a sub-millisecond time scale, and further introduces zero-phase component analysis (ZCA) as a method to remove these artifacts from the data. Thus, we recommend to use ZCA as a general preprocessing for electrophysiological recordings.

neuroscience↗