Search bioRxiv⌕ Search

Biology subjects

Obaid, S. N.

Publications and source records attributed to Obaid, S. N..

4 recordsLinked to original sources

Soft multimodal opto-electric biointerfaces for co-localized optical and electrical recording of cell function

Optical fluorescence and electrical monitoring of cell activity are two powerful approaches to study organ functions. Simultaneous recording of optical and electrical data types will provide complementary information from and take advantage of each approach. However, devices that can concurrently record optical signals from the same cell population underneath the microelectrodes have not been widely explored and remain a grand technical challenge. This work presents an innovative flexible opto-electric device that monolithically integrates transparent gold nanogrid microelectrodes directly above microscale light-emitting diodes, photodetectors, and optical filters to achieve co-localized crosstalk-free optical fluorescence and electrical recording. The optimized gold nanogrid microelectrodes show excellent optical transparency (>81%) and low normalized 1 kHz electrochemical impedance (6.3 {Omega} cm2). The optical recording subsystem offers high wavelength selectivity (>1,300) and linearity (R2 >0.99) for exciting and capturing green fluorescence from various fluorescent reporters in measurement ranges relevant to in vivo applications with minimal thermal effects. The opto-electric device exhibits remarkable durability under soaking for 40 days and repetitive mechanical bending for 5,000 cycles. The work may provide a versatile approach for constructing mechanically compliant biointerfaces containing crosstalk-free optical and electrical modalities with widespread application potentials in basic and clinical research.

bioengineering↗

Multifunctional flexible electro-optical arrays for simultaneous spatiotemporal cardiac mapping and modulation

Bioelectronic devices that allow simultaneous accurate monitoring and control of the spatiotemporal patterns of cardiac activity provide an effective means to understand the mechanisms and optimize therapeutic strategies for heart disease. Optogenetics is a promising technology for cardiac research due to its advantages such as cell-type selectivity and high space-time resolution, but its efficacy is limited by the insufficient number of modulation channels and lack of simultaneous spatiotemporal mapping capabilities in current cardiac optogenetics tools. Here we present soft implantable electro-optical cardiac devices integrating multilayered highly uniform arrays of transparent microelectrodes and multicolor micro-light-emitting-diodes in thin, flexible platforms for mechanically compliant high-content electrical mapping and single-/multi-site optogenetics and electrical stimulation without light-induced artifacts. Systematic benchtop characterizations, together with ex vivo and in vivo evaluations on healthy and diseased small animal and human hearts demonstrate their functionalities in real-time spatiotemporal mapping and control of cardiac rhythm and function, with broad applications in basic and ultimately clinical cardiology.

bioengineering↗

Flexible and transparent silver nanowire structures for multifunctional electrical and optical biointerfacing

Transparent microelectrodes have recently emerged as a promising approach to combine electrophysiology with optophysiology for multifunctional biointerfacing. High-performance flexible platforms that allow seamless integration with soft tissue systems for such applications are urgently needed. Here, silver nanowires (Ag NWs)-based transparent microelectrodes and interconnects are designed to meet this demand. The Ag NWs percolating networks are patterned on flexible polymer substrates using an innovative photolithography-based solution-processing technique. The resulting nanowire networks exhibit a high average optical transparency of 76.1-90.0% over the visible spectrum, low normalized electrochemical impedance of 3.4-15 {Omega} cm2 at 1 kHz which is even better than those of opaque solid Ag films, superior sheet resistance of 11-25 {Omega} sq-1, excellent mechanical stability up to 10,000 bending cycles, good biocompatibility and chemical stability. Studies on Langendorff-perfused mouse and rat hearts demonstrate that the Ag NWs microelectrodes enable high-fidelity real-time monitoring of heart rhythm during co-localized optogenetic pacing and optical mapping with negligible light-induced electrical artifacts. This proof-of-concept work illustrates that the solution-processed, transparent, and flexible Ag NWs networks are a promising candidate for the next-generation of large-area multifunctional biointerfaces for interrogating complex biological systems in basic and translational research.

bioengineering↗

p38delta genetic ablation protects female mice from anthracycline cardiotoxicity

BACKGROUNDThe efficacy of an anthracycline antibiotic doxorubicin (DOX) as a chemotherapeutic agent is limited by dose-dependent cardiotoxicity. DOX is associated with activation of intracellular stress signaling pathways including p38 MAPKs. While previous studies have implicated p38 MAPK signaling in DOX-induced cardiac injury, the roles of the individual p38 isoforms, specifically, of the alternative isoforms p38{gamma} and p38{delta}, remain uncharacterized. OBJECTIVESTo determine the potential cardioprotective effects of p38{gamma} and p38{delta} genetic deletion in mice subjected to acute DOX treatment. METHODSMale and female wild-type (WT), p38{gamma}-/-, p38{delta}-/- and p38{gamma}-/-{delta}-/- mice were injected with 30 mg/kg DOX and their survival was tracked for ten days. During this period cardiac function was assessed by echocardiography and electrocardiography and fibrosis by PicroSirius Red staining. Immunoblotting was performed to assess the expression of signaling proteins and markers linked to autophagy. RESULTSSignificantly improved survival was observed in p38{delta}-/- female mice post-DOX relative to WT females, but not in p38{gamma}-/- or p38{gamma}-/-{delta}-/- male or female mice. The improved survival in DOX-treated p38{delta}-/- females was associated with decreased fibrosis, increased cardiac output and LV diameter relative to DOX-treated WT females, and similar to saline-treated controls. Structural and echocardiographic parameters were either unchanged or worsened in all other groups. Increased autophagy, as evidenced by increased LC3-II level, and decreased mTOR activation was also observed in DOX-treated p38{delta}-/- females. CONCLUSIONSp38{delta} plays a crucial role in promoting DOX-induced cardiotoxicity in female mice by inhibiting autophagy. Therefore, p38{delta} targeting could be a potential cardioprotective strategy in anthracycline chemotherapy. NEW AND NOTEWORTHYThis study for the first time identifies the roles of the alternative p38{gamma} and p38{delta} MAPK isoforms in promoting DOX-cardiotoxicity in a sex-specific manner. While p38{gamma} systemic deletion did not affect DOX-cardiotoxicity, p38{delta} systemic deletion was cardioprotective in female but not in male mice. Cardiac structure and function were preserved in DOX-treated p38{delta}-/- females and autophagy was increased.

physiology↗