Search bioRxiv⌕ Search

Biology subjects

Noetscher, G. M.

Publications and source records attributed to Noetscher, G. M..

11 recordsLinked to original sources

Accurate Hippocampal Electric Field Modeling for Electroconvulsive Therapy: Numerical Accuracy and Convergence

Accurate hippocampal electric field (E-field) prediction is important for individualized electroconvulsive therapy (ECT) dosing and emerging deep-brain stimulation approaches such as temporal interference. Because hippocampal fields are far weaker than those beneath the stimulation electrodes, they are highly sensitive to tissue interfaces, conductivity contrasts, and numerical discretization, so numerical error can rival the physical uncertainties of anatomy and conductivity. We investigate this numerical component of hippocampal dosimetry using individualized head models from eleven ECT patients. Identical head40 segmentations, comprising 40 tissue compartments including the bilateral hippocampi, were simulated with three independent numerical methods: a charge-based boundary-element fast multipole method (BEM-FMM), a voxel-based hexahedral finite-element solver, and a conformal tetrahedral finite-element solver. For each, resolution was increased systematically and convergence assessed from the average hippocampal E-field magnitude. At the highest attainable resolutions, the three methods agreed closely, differing by 6%-7% in the left hippocampus and 9%-12% in the right. At default or coarse resolutions, however, they disagreed by 28.8% on average and up to 50.3% in the right hippocampus. Numerical convergence should therefore be established before differences are attributed to anatomical or conductivity uncertainty, and independent-solver agreement provides a practical basis for reliable hippocampal dosimetry.

neuroscience↗

High-Resolution EEG Source Reconstruction from PCA-Corrected BEM-FMM Reciprocal Basis Funcions: A Study with Visual Evoked Potentials from Intermittent Photic Stimulation

Modern automated human head segmentations can generate high-resolution computational meshes involving many non-nested tissues. However, most source reconstruction software is limited to 3 -4 nested layers of low resolution and a small number of dipolar sources[~] 10, 000. Recently, we introduced modeling techniques for source reconstruction of magnetoencephalographic (MEG) signals using the reciprocal approach and the boundary element fast multipole method (BEM-FMM). The technique of BEM-FMM can process both nested and non-nested models with as many as 4 million surface elements. In this paper, we present an analogue technique for source reconstruction of electroencephalographic (EEG) signals based on cortical global basis functions. The present work uses Helmholtz reciprocity to relate the reciprocally-generated lead-field matrices to their direct counterpart, while resolving the issue of possible biases toward the reference electrode. Our methodology is tested with experimental EEG data collected from a cohort of 12, young and healthy, volunteers subjected to intermittent photic stimulation (IPS). Our novel high-resolution source reconstruction models can have impact on mental health screening as well as brain-computer inter-faces.

neuroscience↗

Improved Source Localization of Auditory Evoked Fields using Reciprocal BEM-FMM

The precise localization of auditory evoked fields (AEFs) from magnetoencephalography (MEG) data is very important for the functional understanding of the auditory cortex in medicine and cognitive neuroscience. The numerical solution of the field equations in the human head using the boundary element method (BEM) is a powerful tool for achieving this. We hypothesized that the spatial resolution of the BEM is crucial for the achievable accuracy. However, in classical BEM (as implemented, e.g., in MNE-Python), very high resolutions are impractical due to the associated prohibitive computational effort. In contrast, our recently introduced reciprocal boundary element fast multipole method (reciprocal BEM-FMM) allows for hitherto unprecedented spatial resolution. In this work, we apply our reciprocal BEM-FMM technique for source estimation to localize AEFs, and we compare our results with the source estimates produced using a 3-layer BEM model (standard BEM) via MNE-Python. We first validate our methodology through comparison of source estimates of simulated N1m components of AEFs using a receiver operating characteristic (ROC) measure. While we obtain ROC measures of about 80% for the standard BEM, reciprocal BEM-FMM reaches about 90%, a significant statistical improvement. We then apply this methodology to analyze the source estimates of experimental data obtained from a cohort of 7 participants subjected to binaural auditory stimulation. Using a dispersion measurement to quantify the focality of localized sources, we find improvements upwards of 30% using reciprocal BEM-FMM over the standard BEM. Analyses from both simulated and experimental data show localization of AEFs using high-resolution reciprocal BEM-FMM is significantly better in terms of accuracy and focality than those estimates of the low-resolution standard BEM. We therefore recommend using the high-resolution reciprocal BEM-FMM to utilize high spatial anatomical precision for the modeling of neural activity.

neuroscience↗

High-Definition MEG Source Estimation using the Reciprocal Boundary Element Fast Multipole Method

Magnetoencephalographic (MEG) source estimation relies on the computation of the gain (lead-field) matrix, which embodies the linear relationship between the amplitudes of the sources and the recorded signals. However, with a realistic forward model, the calculation of the gain matrix in a "direct" fashion is a computationally expensive task because the number of dipolar sources in standard MEG pipelines is often limited to [~]10,000. We propose a fast approach based on the reciprocal relationship between MEG and transcranial magnetic stimulation (TMS). This approach couples naturally with the charge-based boundary element fast multipole method (BEM-FMM), which allows us to efficiently generate gain matrices for high-resolution multi-layer non-nested meshes involving source spaces of up to a [~]1 million dipoles. We evaluate our approach by performing MEG source reconstruction against simulated data (at varying noise levels) obtained from the direct computation of MEG readings from 2000 different dipole positions over the cortical surface of 5 healthy subjects. Additionally, we test our methods with real MEG data from evoked somatosensory fields by right-hand median nerve stimulation in these same 5 subjects. We compare our experimental source reconstruction results against the standard MNE-Python source reconstruction pipeline.

neuroscience↗

Electromagnetic Modeling within a Microscopically Realistic Brain - Implications for Brain Stimulation

Modeling brain stimulation at the microscopic scale may reveal new paradigms for various stimulation modalities. We present the largest map to date of extracellular electric field distributions within a layer L2/L3 mouse primary visual cortex brain sample. This was enabled by the automated analysis of serial section electron microscopy images with improved handling of image defects, covering a volume of 250 x 140 x 90 m3. The map was obtained by applying a uniform brain stimulation electric field at three different polarizations and accurately computing microscopic field perturbations using the boundary element fast multipole method. We used the map to identify the effect of microscopic field perturbations on the activation thresholds of individual neurons. Previous relevant studies modeled a macroscopically homogeneous cortical volume. Our result shows that the microscopic field perturbations - an electric field spatial noise with a mean value of zero - only modestly influence the macroscopically predicted stimulation field strengths necessary for neuronal activation. The thresholds do not change by more than 10% on average. Under the stated limitations and assumptions of our method, this result justifies the conventional theory of "invisible" neurons embedded in a macroscopic brain model for transcranial magnetic and transcranial electrical stimulation. However, our result is solely sample-specific and largely neglects the effect of the microcapillary network. Furthermore, we only considered the uniform impressed field and a single- pulse stimulation time course. Significance statementThis study is arguably the first attempt to model brain stimulation at the microscopic scale, enabled by automated analysis of modern scanning electron microscopy images of the brain. It concentrates on modeling microscopic perturbations of the extracellular electric field caused by the physical cell structure and is applicable to any type of brain stimulation. Data availability statementPost-processed cell CAD models (383, stl format), microcapillary CAD models (34, stl format), post-processed neuron morphologies (267, swc format), extracellular electric field and potential distributions at different polarizations (267x3, MATLAB format), *.ses projects files for biophysical modeling with Neuron software (267x2, Neuron format), and computed neuron activating thresholds at different conditions (267x8, Excel tables, without the sample polarization correction from Section 2.8) are made available online through BossDB, a volumetric open-source database for 3D and 4D neuroscience data.

neuroscience↗

An In-Silico Testbed for Fast and Accurate MR Labeling of Orthopaedic Implants

AO_SCPLOWBSTRACTC_SCPLOWOne limitation on the ability to monitor health in older adults using Magnetic Resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: - an in-silico human model based on the widely available Visible Human Project (VHP) cryo-section dataset; - a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The in-silico VHP Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index (BMI) of 36. The testbed includes the FEM-compatible in-silico human model, an implant embedding procedure, a generic parameterizable MRI RF birdcage two-port coil model, a workflow for computing heat sources on the implant surface and in adjacent tissues, and a thermal FEM solver directly linked to the MR coil simulator to determine implant heating based on an MR imaging study protocol. The primary target is MR labeling of large orthopaedic implants. The testbed has very recently been approved by the US Food and Drug Administration (FDA) as a medical device development tool (MDDT) for 1.5 T orthopaedic implant examinations.

biophysics↗

Software Toolkit for Fast High-Resolution TMS Modeling

Computational modeling of Transcranial Magnetic Stimulation (TMS) is a tradeoff between computational speed vs. spatial precision. In this study, we introduce a software toolkit for high-resolution TMS modeling, which may offer the best of both. The toolkit employs the recently developed boundary element fast multipole method (BEM-FMM) with accurate solution computations close to tissue interfaces. It operates within the MATLAB platform and is designed for a broad, medically-oriented computational research community. To enable easy, subject-specific operation, the package is compatible with human head models generated with automated tools such as SimNIBS and FreeSurfer.\n\nBoth coil design in free space as well as efficacy and focality of TMS for a specific subject could be modeled by the package, including optional user-defined parametric loops. Detailed and widely used coil models, generated in both CAD and wire formats, may include several hundred thousand elementary current elements and observation spaces with approximately 1 M field points; the corresponding computational times are on the order of 1 sec. Detailed head models with approximately 1 M triangular facets and a mesh resolution of 0.6 points per mm2 are simulated in approximately 1.5 min which is arguably the fastest time to date. Further reduction of computational times is foreseen. The toolkit is augmented with a population of 16 ready-to-use head models for performing simulations for computational studies that do not involve MRI data collection. The toolkit is also augmented with a coil geometry generator capable of creating accurate coil models.

neuroscience↗

Modeling Primary Fields of TMS Coils with the Fast Multipole Method

AbstractIn this study, an accurate TMS-coil modeling approach based on conductors cross-section representation with many distributed current filaments coupled with an efficient fast multipole method (FMM) accelerator is developed and tested. Uniform (Litz wire) or skin-effect based current distributions are included into consideration. Speed and accuracy estimates as well as two application examples are given, which indicate that this approach is potentially capable of rapid and accurate evaluation of various detailed TMS coil designs and arrays of such coils.\n\nThe MATLAB-based wire and CAD mesh generator for the coil geometry is interfaced with the FMM FORTAN program, which is also compiled within the MATLAB shell. No extra MATLAB toolboxes are necessary. The CAD model of the coil can be imported into any other computational software package in STL format. The algorithm is organized in the form of a MATLAB-based toolkit. First, a coil model is generated using a dedicated script. Then, we compute high-resolution 2D contour plots for any component of the electric and/or magnetic field in coronal, sagittal, and transverse planes via FMM. These two scripts may be further augmented with a parametric loop to enable rapid analysis.\n\nObjectiveWe show how the fast multipole method can be applied to compute primary electric and magnetic fields for detailed TMS coil models

neuroscience↗

Collection of Sixteen High-Quality Human Head CAD Models Generated with SimNIBS 2.1 Using Connectome Subject Data within MATLAB(R) Platform

The goal of this study is to introduce a collection of sixteen high-resolution, 2-manifold CAD compatible head models within the MATLAB platform available to all interested parties for electromagnetic and acoustic simulations. Each model contains skin, skull, CSF, GM, cerebellum, WM, and ventricles head compartments and possesses an \"onion\" topology: the grey matter shell is a container for white matter, ventricles, and cerebellum objects, the CSF shell contains the grey matter shell, the skull shell contains the CSF shell, and finally the skin or scalp shell contains the skull shell. The models are fully compatible with ANSYS ED FEM software, CST Studio Suite, Sim4Life/SEMCAD software, and other electromagnetic software packages.\n\nThe collection is based on MRI data from the Human Connectome Project (HCP) segmented using the SimNIBS 2.1/2.1.1 processing pipeline. The average number of triangular surface facets in a model is 866,000, the average triangle quality is 0.25, the average edge length is 1.48 mm, and the average surface mesh density or resolution is 0.57 points per mm2. If necessary, a finer model mesh can be created for every head using available MATLAB tools.

bioengineering↗

Design and Analysis of a Whole Body Non-Contact Electromagnetic Stimulation Device with Field Modulation

This study describes a whole-body, non-contact electromagnetic stimulation device based on the concept of a conventional MRI Radio Frequency (RF) resonating coil, but at a much lower resonant frequency (100-150 kHz), with a field modulation option (0.5-100 Hz) and with an input power of up to 3 kW. Its unique features include a high electric field level within the biological tissue due to the resonance effect and a low power dissipation level, or a low Specific Absorption Rate (SAR), in the body itself. Because of its large resonator volume together with non-contact coupling, the subject may be located anywhere within the coil over a longer period at moderate and safe electric field levels. The electric field effect does not depend on body position within the resonator. However, field penetration is deep anywhere within the body, including the extremities where muscles, bones, and peripheral tissues are mostly affected. A potential clinical application of this device is treatment of chronic pain. Substantial attention is paid to device safety; this includes both AC power safety and exposure of human subjects to electromagnetic fields. In the former case, we employ inductive coupling which eliminates a direct current path from AC power to the coil. Our design enhances overall device safety at any power level, even when operated under higher-power conditions. Human exposure to electromagnetic fields within the coil is evaluated by performing modeling with two independent numerical methods and with an anatomically realistic multi-tissue human phantom. We show that SAR levels within the body correspond to International Electrotechnical Commission (IEC) safety standards when the input power level of the amplifier driver does not exceed 3 kW. We also show that electric field levels generally comply with International Commission on Non-Ionizing Radiation Protection safety standards if the input power level does not exceed 1.5 kW.

bioengineering↗

Microscopic and Macroscopic Response of a Cortical Neuron to an External Electric Field Computed with the Boundary Element Fast Multipole Method

The goal of this study is to demonstrate how one can compute the activating function and surface charge density resulting from application of an external electric field to a high-resolution realistic neuronal morphology. We use the boundary element fast multipole method (BEM-FMM) on an ordinary computer to accurately perform these computations in under 2-10 minutes for a dense surface mesh of a single neuron with approximately 1.4 million triangles. Prior work used commercial finite element method (FEM) software which required creation of a volumetric tetrahedral mesh between fine neuronal arbor, potentially resulting in prohibitively large volume sizes and long mesh generation times. We used the example of a human pyramidal neuron with an externally applied E-field to show how our approach can quickly and accurately compute the induced surface charge density on the cell surface and the activating function of the cable equation. We found that the induced surface charge density perturbs the macroscopically applied E-field on a microscopic spatial scale. The strength of the perturbation depends on the conductivity contrast; the stronger the contrast, the larger the perturbation. In our example, the induced surface charge density may change the average activating function by up to 75%. We also embedded this neuron model into a detailed macroscopic human head model and simulated a realistic TMS excitation using the BEM-FMM method for the combined model. The solution obtained in this case predicted a smaller activating function error. The difference between the microscopic and the macroscopic effect of the externally applied electric field is of much interest to users of extracellular stimulation techniques and merits further study.

neuroscience↗