Search bioRxiv⌕ Search

Biology subjects

Nissi, M. J.

Publications and source records attributed to Nissi, M. J..

2 recordsLinked to original sources

An Automated and Robust Tool for Musculoskeletal and Finite Element Modeling of the Knee Joint

ObjectiveTo develop and assess an automatic and robust knee musculoskeletal finite element (MSK-FE) modeling pipeline. MethodsMagnetic resonance images (MRI) were used to train nnU-Net networks for auto-segmentation of knee bones (femur, tibia, patella, and fibula), cartilages (femur, tibia, and patella), menisci, and major knee ligaments. Two different MRI sequences were used to broaden applicability. Next, we created MSK-FE models of an unseen dataset using two MSK-FE modeling pipelines: template-based and auto-meshing. MSK models had personalized knee geometries with multi-degree-of-freedom elastic foundation contacts. FE models used fibril-reinforced poroviscoelastic swelling material models for cartilages and menisci. ResultsVolumes of knee bones, cartilages, and menisci did not significantly differ (p>0.05) across MRI sequences. MSK models estimated secondary knee kinematics during passive knee flexion tests consistent with in vivo and simulation-based values from the literature. Between the template-based and auto-meshing FE models, estimated cartilage mechanics often differed significantly (p<0.05), though differences were <15% (considering peaks during walking), i.e., <1.5 MPa for maximum principal stress, <1 percentage point for collagen fibril strain, and <3 percentage points for maximum shear strain. ConclusionThe template-based modeling provided a more rapid and robust tool than the auto-meshing approach, while the estimated knee biomechanics were comparable. Nonetheless, the auto-meshing approach might provide more accurate estimates in subjects with distinct knee irregularities, e.g., cartilage lesions. SignificanceThe MSK-FE modeling tool provides a rapid, easy-to-use, and robust approach to investigating task- and person-specific mechanical responses of the knee cartilage and menisci, holding significant promise, e.g., in personalized rehabilitation planning.

bioengineering↗

A musculoskeletal finite element model of rat knee joint for evaluating cartilage biomechanics during gait

Abnormal loading of the knee due to injuries or obesity is thought to contribute to the development of osteoarthritis (OA). Small animal models have been used for studying OA progression mechanisms. However, numerical models to study cartilage responses under dynamic loading in preclinical animal models have not been developed. Here we present a musculoskeletal finite element (FE) model of a rat knee joint to evaluate cartilage biomechanical responses during a gait cycle. The rat knee joint geometries were obtained from a 3-D MRI dataset and the boundary conditions regarding loading in the joint were extracted from a musculoskeletal model of the rat hindlimb. The fibril-reinforced poroelastic (FRPE) properties of the rat cartilage were derived from data of mechanical indentation tests. Our numerical results showed the relevance of simulating anatomical and locomotion characteristics in the rat knee joint for estimating tissue responses such as contact pressures, stresses, strains, and fluid pressures. We found that the contact pressure and maximum principal strain were virtually constant in the medial compartment whereas they showed the highest values at the beginning of the gait cycle in the lateral compartment. Furthermore, we found that the maximum principal stress increased during the stance phase of gait, with the greatest values at midstance. We anticipate that our approach serves as a first step towards investigating the effects of gait abnormalities on the adaptation and degeneration of rat knee joint tissues and could be used to evaluate biomechanically-driven mechanisms of the progression of OA as a consequence of joint injury or obesity. Author SummaryOsteoarthritis is a disease of the musculoskeletal system which is characterized by the degradation of articular cartilage. Changes in the knee loading after injuries or obesity contribute to the development of cartilage degeneration. Since injured cartilage cannot be reversed back to intact conditions, small animal models have been widely used for investigating osteoarthritis progression mechanisms. Moreover, experimental studies have been complemented with numerical models to overcome inherent limitations such as cost, difficulties to obtain accurate measures and replicate degenerative situations in the knee joint. However, computational models to study articular cartilage responses under dynamic loading in small animal models have not been developed. Thus, here we present a musculoskeletal finite element model of a rat knee joint to evaluate cartilage biomechanical responses during gait. Our computational model considers both the anatomical and locomotion characteristics of the rat knee joint for estimating mechanical responses in the articular cartilage. We suggest that our approach can be used to investigate tissue adaptations based on the mechanobiological responses of the cartilage to prevent the progression of osteoarthritis.

bioengineering↗