Search bioRxivSearch

Biology subjects

Ngamsombat, C.

Publications and source records attributed to Ngamsombat, C..

2 recordsLinked to original sources

High-fidelity fast volumetric brain MRI using a hybrid denoising generative adversarial network (HDnGAN)

PurposeReducing scan times is important for wider adoption of high-resolution volumetric MRI in research and clinical practice. Emerging fast imaging and deep learning techniques provide promising strategies to accelerate volumetric MRI without compromising image quality. In this study, we aim to leverage an advanced fast imaging technique, wave-controlled aliasing in parallel imaging (Wave-CAIPI), and a novel denoising generative adversarial network (GAN) to achieve accelerated high-fidelity, high-signal-to-noise-ratio (SNR) volumetric MRI. Methods3D T2-weighted fluid-attenuated inversion recovery (FLAIR) image data were acquired on 33 multiple sclerosis (MS) patients using a prototype Wave-CAIPI sequence (acceleration factor R=3x2, 2.75 minutes) and a standard T2-SPACE FLAIR sequence (R=2, 7.25 minutes). A hybrid denoising GAN entitled "HDnGAN" composed of a 3D generator (i.e., a modified 3D U-Net entitled MU-Net) and a 2D discriminator was proposed to denoise Wave-CAIPI images with the standard FLAIR images as the target. HDnGAN was trained and validated on data from 25 MS patients by minimizing a combined content loss (i.e., mean squared error (MSE)) and adversarial loss with adjustable weight{lambda} , and evaluated on data from 8 patients unseen during training. The quality of HDnGAN-denoised images was compared to those from other denoising methods including AONLM, BM4D, MU-Net, and 3D GAN in terms of their similarity to standard FLAIR images, quantified using MSE and VGG perceptual loss. The images from different methods were assessed by two neuroradiologists using a five-point score regarding sharpness, SNR, lesion conspicuity, and overall quality. Finally, the performance of these denoising methods was compared at higher noise levels using simulated data with added Rician noise. ResultsHDnGAN effectively denoised noisy Wave-CAIPI images with sharpness and rich textural details, which could be adjusted by controlling{lambda} . Quantitatively, HDnGAN ({lambda}=10-3) achieved low MSE (7.43 x10-4{+/-}0.94x10-4) and the lowest VGG perceptual loss (1.09x10-2{+/-}0.18x10-2). The reader study showed that HDnGAN ({lambda}=10-3) significantly improved the SNR of Wave-CAIPI images (4.19{+/-}0.39 vs. 2.94{+/-}0.24, P<0.001), outperformed AONLM (4.25{+/-}0.56 vs. 3.75{+/-}0.90, P=0.015), BM4D (3.31{+/-}0.46, P<0.001), MU-Net (3.13{+/-}0.99, P<0.001) and 3D GAN ({lambda}=10-3) (3.31{+/-}0.46, P<0.001) regarding image sharpness, and outperformed MU-Net (4.21{+/-}0.67 vs. 3.29{+/-}1.28, P<0.001) and 3D GAN ({lambda}=10-3) (3.5{+/-}0.82, P=0.001) regarding lesion conspicuity. The overall quality score of HDnGAN ({lambda}=10-3) (4.25{+/-}0.43) was significantly higher than those from Wave-CAIPI (3.69{+/-}0.46, P=0.003), BM4D (3.50{+/-}0.71, P=0.001), MU-Net (3.25{+/-}0.75, P<0.001), and 3D GAN ({lambda}=10-3) (3.50{+/-}0.50, P<0.001), with no significant difference compared to standard FLAIR images (4.38{+/-}0.48, P=0.333). The advantages of HDnGAN over other methods were more obvious at higher noise levels. ConclusionHDnGAN provides robust and feasible denoising while preserving rich textural detail in empirical volumetric MRI data and is superior on both quantitative and qualitative evaluation compared to the original Wave-CAIPI images and images denoised using standard methods. HDnGAN concurrently benefits from the improved image synthesis performance of the 3D convolution and the increased number of samples for training the 2D discriminator from a limited number of subjects. Our study supports the use of HDnGAN in combination with modern fast imaging techniques such as Wave-CAIPI to achieve high-fidelity fast volumetric MRI.

neuroscience

Improved cortical surface reconstruction using sub-millimeter resolution MPRAGE by image denoising

Automatic cerebral cortical surface reconstruction is a useful tool for cortical anatomy quantification, analysis and visualization. Recently, the Human Connectome Project and several studies have shown the advantages of using T1-weighted magnetic resonance (MR) images with sub-millimeter isotropic spatial resolution instead of the standard 1-millimeter isotropic resolution for improved accuracy of cortical surface positioning and thickness estimation. Nonetheless, sub-millimeter resolution images are noisy by nature and require averaging multiple repetitions to increase the signal-to-noise ratio for precisely delineating the cortical boundary. The prolonged acquisition time and potential motion artifacts pose significant barriers to the wide adoption of cortical surface reconstruction at sub-millimeter resolution for a broad range of neuroscientific and clinical applications. We address this challenge by evaluating the cortical surface reconstruction resulting from denoised single-repetition sub-millimeter T1-weighted images. We systematically characterized the effects of image denoising on empirical data acquired at 0.6 mm isotropic resolution using three classical denoising methods, including denoising convolutional neural network (DnCNN), block-matching and 4-dimensional filtering (BM4D) and adaptive optimized non-local means (AONLM). The denoised single-repetition images were found to be highly similar to 6-repetition averaged images, with a low whole-brain averaged mean absolute difference of [~]0.016, high whole-brain averaged peak signal-to-noise ratio of [~]33.5 dB and structural similarity index of 0.92, and minimal gray matter-white matter contrast loss (2% to 9%). The whole-brain mean absolute discrepancies in gray-white surface placement, gray-CSF surface placement and cortical thickness estimation were lower than 165 m, 155 m and 145 m--sufficiently accurate for most applications. The denoising performance is equivalent to averaging [~]2.5 repetitions of the data in terms of image similarity, and 1.6-2.2 repetitions in terms of the cortical surface placement accuracy. The scan-rescan precision of the cortical surface positioning and thickness estimation was lower than 170 m. Our unique dataset and systematic characterization support the use of denoising methods for improved cortical surface reconstruction sub-millimeter resolution.

bioengineering