Search bioRxiv⌕ Search

Biology subjects

Nathan, M.

Publications and source records attributed to Nathan, M..

2 recordsLinked to original sources

EDTA tubes are suitable for insulin and C-peptide measurement in resource-limited settings and can be stored at room temperature for up to 24 hours

IntroductionInsulin and C-peptide assessment are important in characterization and management of diabetes. However, their adoption and increased clinical use in low resource settings (LRSs) is partly hindered by logistical factors including supplies required for pre-analytical sample handling and limited infrastructure. We aimed to determine the effects of altered sample processing conditions on stability of insulin and C-peptide at the pre-analytical stage. MethodsWe investigated the stability of C-peptide and insulin in serum and plasma collected, preservative type, time to centrifugation, storage conditions and duration of storage on the stability of C-peptide and insulin over 24 hours. ResultsBoth C-peptide and insulin levels remained stable above 90% from baseline p=1.000 & p=0.776 over 24 hours for samples stored in K2EDTA tubes, whether at room temperature or in a cooler box, both as centrifuged and uncentrifuged whole blood. In contrast, samples collected in plain serum tubes kept at room temperature and uncentrifuged C-peptide and insulin levels decreased significantly to 51%, p=0.006 and 62%, p=0. 083 respectively, similarly insulin levels for centrifuged samples declined to 64%, p=0.083 All iced and centrifuged serum samples remained above 90% of baseline concentration. ConclusionsIn resource limited settings where insulin and c-peptide tests are limited to central laboratories and highly dependent on sample referral systems, these tests can be reliably measured without the need for immediate centrifugation or processing from samples collected in whole blood K2EDTA tubes uncentrifuged kept at room temperature and processed within 24hours. MessageK2EDTA tubes can be used for sample collection in resource limited setting kept at room temperature for up to 24hrs for insulin and c-peptide assays. K2EDTA plasma is more stable than serum for insulin and c-peptide measurement and should be used in resource limited settings

biochemistry↗

Sustained hovering, head stabilization and vision through the water surface in the Pied kingfisher (Ceryle rudis).

Pied kingfishers (Ceryle rudis) capture fish by plunge diving from hovering that may last several minutes. Hovering is the most energy-consuming mode of flight and depends on active wing flapping and facing headwind. The power for hovering is mass dependent increasing as the cube of the size, while aerodynamic forces increase only quadratically with size. Consequently, birds above a certain body mass can hover only with headwind and for very short durations. Hummingbirds are referred to as the only birds capable of hovering without wind (sustained hovering) due to their small size (ca. 2-20 gr), high wing-beat frequency and unique anatomy.\n\nWe studied the hovering characteristics of pied kingfishers in relation to wind and sun orientation, in 139 hovers. Furthermore, plunge diving necessitates the coping with the visual effects of light at the air/water interface. The kingfishers oriented their body axis towards the wind more than towards the sun. Hovering in little or no wind was common. With increased wind speed (a) orientation precision increased, (b) wing beat amplitude did not change, (c) wing beat frequency decreased and (d) body tilt became more horizontal. The head was highly stabilized and with orientations that indicated monocular viewing of prey.\n\nWe conclude that pied kingfishers achieve sustained hovering. This is despite their being significantly heavier than the theoretical maximum and showing ordinary kinematics and morphology. Head stabilization is a means of aiding viewing of submerged prey across the interface.

zoology↗