Search bioRxiv⌕ Search

Biology subjects

Morgan, P. S.

Publications and source records attributed to Morgan, P. S..

2 recordsLinked to original sources

Does Denoising Reduce Cross-Vendor Variability in Diffusion MRI? A Travelling Heads Evaluation

Between-scanner variability in magnetic resonance imaging (MRI)-derived features can be comparable to biological between-subject variability, even for the same individual scanned at different sites. MRI harmonisation is therefore an essential tool to ensure studies are generalisable across sites, reducing between-scanner variability and enabling pooling of data to achieve large sample sizes and more representative population samples. Denoising using MPPCA is widely used in preprocessing pipelines for diffusion MRI acquisitions to improve image SNR and it has been proposed as an implicit way of harmonising data. In this registered report, we hypothesised that denoising reduces cross-scanner variability and improves reliability in diffusion MRI metrics without changing cross-scanner bias, and that susceptibility-induced off-resonance reduces its efficacy. We tested these hypotheses using a travelling-heads resource of ten subjects scanned on six scanners from three vendors (GE, Philips, Siemens), with within-scanner repeats. We found that: i) Denoising reduced voxel-wise cross-scanner coefficients of variation for fractional anisotropy (FA), mean diffusivity (MD) and mean kurtosis (MK) (BF > 100; median -3%, -9% and -32%). ROI-wise, variability decreased for MK (-12%), increased for FA (+8%), and evidence was inconclusive for MD. ii) Contrary to our hypothesis, denoising changed cross-scanner bias in every subject-scanner pair, by up to 3% of the mean; in exploratory analyses, this change was strongly related to contrast-to-noise ratio. iii) Evidence for a change in the registered measure of reliability was inconclusive, although exploratory analyses showed higher voxel-wise reliability after denoising. iv) There was no convincing evidence that off-resonance reduces denoising efficacy. Together, these results suggest that MPPCA denoising reduces the random, noise-driven component of cross-scanner variability, most strongly at the voxel level and for kurtosis, but does not consistently reduce systematic differences between scanners. As such, it should complement harmonisation, not replace it.

neuroscience↗

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising

PurposeOptimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCares AIR-Recon DL (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to open-source PCA-based MPPCASVS and NORDIC denoising methods on high-resolution dMRI data. MethodsWe developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCASVS, NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the ADC profiles in highly anisotropic areas, and downstream measurements, such as fiber orientation estimation and white matter tractography. ResultsOur validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL. ConclusionWe found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCASVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution, reduction of noise-floor bias and variance.

neuroscience↗