Search bioRxiv⌕ Search

Biology subjects

Morgan, J. I.

Publications and source records attributed to Morgan, J. I..

2 recordsLinked to original sources

Retinal ganglion cell endowment is correlated with optic tract fiber cross section, not density

There is substantial variation between healthy individuals in the number of retinal ganglion cells (RGC) in the eye, with commensurate variation in the number of axons in the optic tracts. Fixel-based analysis of diffusion MR produces estimates of fiber density (FD) and cross section (FC). Using these fixel measurements along with retinal imaging, we asked if individual differences in RGC tissue volume are correlated with individual differences in FD and FC measurements obtained from the optic tracts, and subsequent structures along the cortical visual pathway. We find that RGC endowment is correlated with optic tract FC, but not with FD. RGC volume had a decreasing relationship with measurements from subsequent regions of the visual system (LGN volume, optic radiation FC/FD, and V1 surface area). However, we also found that the variations in each visual area were correlated with the variations in its immediately adjacent visual structure. We only observed these serial correlations when FC is used as the measure of interest for the optic tract and radiations, but no significant relationship was found when FD represented these white matter structures. From these results, we conclude that the variations in RGC endowment, LGN volume, and V1 surface area are better predicted by the overall cross section of the optic tract and optic radiations as compare to the intra-axonal restricted signal component of these white matter pathways. Additionally, the presence of significant correlations between adjacent, but not distant, anatomical structures suggests that there are multiple, local sources of anatomical variation along the visual pathway.

neuroscience↗

Persistent horizontal and vertical, MR-induced nystagmus in resting state Human Connectome Project data

ObjectiveStrong magnetic fields from magnetic resonance (MR) scanners induce a Lorentz force that contributes to vertigo and persistent nystagmus. Prior studies have reported a predominantly horizontal direction for healthy subjects in a 7 Tesla (T) MR scanner, with slow phase velocity (SPV) dependent on head orientation. Less is known about vestibular signal behavior for subjects in a weaker, 3T magnetic field, the standard strength used in the Human Connectome Project (HCP). The purpose of this study is to characterize the form and magnitude of nystagmus induced at 3T. MethodsForty-two subjects were studied after being introduced head-first, supine into a Siemens Prisma 3T scanner. Eye movements were recorded in four separate acquisitions over 20 minutes. A biometric eye model was fit to the recordings to derive rotational eye position and then SPV. An anatomical template of the semi-circular canals was fit to the T2 anatomical image from each subject, and used to derive the angle of the B0 magnetic field with respect to the vestibular apparatus. ResultsRecordings from 37 subjects yielded valid measures of eye movements. The population-mean SPV {+/-} SD for the horizontal component was -1.38 {+/-} 1.27 deg/sec, and vertical component was -0.93 {+/-} 1.44 deg/sec, corresponding to drift movement in the rightward and downward direction. Although there was substantial inter-subject variability, persistent nystagmus was present in half of subjects with no significant adaptation over the 20 minute scanning period. The amplitude of vertical drift was correlated with the roll angle of the vestibular system, with a non-zero vertical SPV present at a 0 degree roll. InterpretationNon-habituating vestibular signals of varying amplitude are present in resting state data collected at 3T.

neuroscience↗