Search bioRxiv⌕ Search

Biology subjects

Monkongpitukkul, N.

Publications and source records attributed to Monkongpitukkul, N..

3 recordsLinked to original sources

Titanium and platinum coatings reduce inflammation induced by gold on subretinal prosthesis

Subretinal photovoltaic implants provide central vision to patients blinded by atrophic age-related macular degeneration, with acuity limited by their 100-{micro}m pixels. Higher resolution requires smaller pixels incorporating three-dimensional electrodes, which can be fabricated by gold electroplating. However, the retinal response to exposed gold remains poorly characterized. Here, we evaluated gold biocompatibility on subretinal implants in Royal College of Surgeons rats and compared it with platinum- and titanium-coated surfaces. Although in-vivo optical coherence tomography revealed no overt structural disruption, gold implants induced cellular-scale anomalies, including abnormal morphology of rod bipolar cells, microglial accumulation near the implant, and increased cell death within days after implantation. These effects occurred across flat, pillar, and honeycomb geometries, indicating a material-rather than geometry-dependent response. By contrast, platinum- and titanium-coated implants showed substantially lower loss and morphological disruption of rod bipolar cells, together with markedly reduced microglial activation. These findings indicate that exposed gold surfaces can induce acute retinal inflammation and neuronal loss, whereas conformal platinum or titanium coatings substantially improve biocompatibility. Such coatings enable the development of three-dimensional subretinal prostheses with smaller pixels for improved visual resolution.

bioengineering↗

Enhancing Prosthetic Vision by Upgrade of a Subretinal Photovoltaic Implant in situ

In patients with atrophic age-related macular degeneration, subretinal photovoltaic implant (PRIMA) provided visual acuity up to 20/440, matching its 100m pixels size. Next-generation implants with smaller pixels should significantly improve the acuity. This study in rats evaluates removal of a subretinal implant, replacement with a newer device, and the resulting grating acuity in-vivo. Six weeks after the initial implantation with planar and 3-dimensional devices, the retina was re-detached, and the devices were successfully removed. Histology demonstrated a preserved inner nuclear layer. Re-implantation of new devices into the same location demonstrated retinal re-attachment to a new implant. New devices with 22m pixels increased the grating acuity from the 100m capability of PRIMA implants to 28m, reaching the limit of natural resolution in rats. Reimplanted devices exhibited the same stimulation threshold as for the first implantation of the same implants in a control group. This study demonstrates the feasibility of safely upgrading the subretinal photovoltaic implants to improve prosthetic visual acuity.

neuroscience↗

3D electronic implants in subretinal space: long-term follow-up in rodents

Photovoltaic subretinal prosthesis (PRIMA) enables restoration of sight via electrical stimulation of the interneurons in degenerated retina, with resolution limited by the 100 m pixel size. Since decreasing the pixel size below 75 m in the current bipolar geometry is impossible, we explore the possibility of using smaller pixels based on a novel 3-dimensional honeycomb-shaped design. We assessed the long-term biocompatibility and stability of these arrays in rats by investigating the anatomical integration of the retina with flat and 3D implants and response to electrical stimulation over lifetime - up to 9 months post-implantation in aged rats. With both flat and 3D implants, VEP amplitude decreased after the day of implantation by more than 3-fold, and gradually recovered over about 3 months. With 25 m high honeycomb walls, the majority of bipolar cells migrate into the wells, while amacrine and ganglion cells remain above the cavities, which is essential for selective network-mediated stimulation of the second-order neurons. Retinal thickness and full-field stimulation threshold with 40 m-wide honeycomb pixels were comparable to those with planar devices - 0.05 mW/mm2 with 10ms pulses. However, fewer cells from the inner nuclear layer migrated into the 20 m-wide wells, and stimulation threshold increased over 5 months, before stabilizing at about 0.08 mW/mm2. Such threshold is significantly lower than 1.8 mW/mm2 with a previous design of flat bipolar pixels, confirming the promise of the 3D honeycomb-based approach to high resolution subretinal prosthesis.

neuroscience↗