Search bioRxiv⌕ Search

Biology subjects

Mol, M. P. H.

Publications and source records attributed to Mol, M. P. H..

6 recordsLinked to original sources

A simplified co-culture reveals altered cardiotoxic responses to doxorubicin in hPSC-derived cardiomyocytes in the presence of endothelial cells

Cardiotoxicity is a significant challenge in cancer therapies, particularly with doxorubicin, a widely used anthracycline known for its broad anti-cancer spectrum but life-threatening cardiac side effects. There is a critical need for more predictive in vitro models to understand doxorubicin-induced cardiotoxicity and patient-specific drug responses. In this study, we used human pluripotent stem cell (hPSC)-derived cardiomyocytes (hPSC-CMs), cardiac fibroblasts (hPSC-cFBs) and endothelial cells (hPSC-ECs) to investigate the cardiotoxic effects of doxorubicin in two-dimensional mono-and multi-cell type cultures. By mimicking the cumulative dose effect seen in patients through repeated doxorubicin treatments and using a machine learning-based in silico image analysis tool, we could precisely quantify caspase 3/7 activity as an early toxicity marker and identify hPSC-CMs in multi-cell type cultures. This innovative approach allowed continuous monitoring of apoptosis from phase-contrast images, revealing that hPSC-ECs showed higher sensitivity to doxorubicin than isogenic hPSC-CMs or hPSC-cFBs and significantly enhanced cardiomyocyte toxicity in co-culture. In contrast, dermal fibroblasts differentiated from the same hPSC line showed no toxic response under the same treatment regimen. These results challenge the conventional focus on cardiomyocytes as the target of drug-induced cardiac damage. Our findings not only highlight the complex interplay among different cardiac cell types in mediating the toxic effects of doxorubicin, but also demonstrate the potential of AI-enabled tools to advance personalized drug screening and safety assessments.

pharmacology and toxicology↗

Industrialization of three-dimensional hiPSC-cardiac microtissues for high-throughput cardiac safety and drug discovery screening

Current cardiac cell models for drug screening often face a trade-off between cellular maturity and achieving high throughput. While three-dimensional human induced pluripotent stem cell-based heart models typically exhibit more adult-like features, their application is hindered by the need for large cell numbers or complex equipment. Here, we developed cost-effective methods to scale up production of three-dimensional cardiac microtissues (cMTs) containing three cardiac cell types, and assess calcium transients and action potential metrics for high-throughput screening (HTS). Automating the procedure revealed reproducible drug responsiveness and predictive accuracy in a reference compound screen. Furthermore, an arrhythmic phenotype was reliably triggered in cMTs containing cardiomyocytes with a RYR2 mutation. A screen of FDA-approved drugs identified 17 drugs that rescued the arrhythmic phenotype. Our findings underscore the scalability of cMTs and their utility in disease modelling and HTS. The advanced "technology-readiness-level" of cMTs supports their regulatory uptake and acceptance within the pharmaceutical industry.

cell biology↗

Gain of chromosome region 1q31.3 in human iPSCs confers growth advantage and alters contraction in derivative cardiomyocytes

hPSCs can acquire chromosomal aberrations such as copy number variations during prolonged maintenance in vitro, conferring growth advantages. However, the effect of these culture-acquired mutations on the phenotypes of the differentiated hPSCs is largely unstudied. Here, we identified mosaicism in a hPSC line in which some cells showed a gain of chromosome 1q31.3. We subcloned the wild-type and variant hPSCs and could maintain both as stable lines. While both variant and wildtype lines differentiated efficiently to cardiomyocytes (hPSC-CMs), molecular analysis revealed the variant hPSC-CMs had increased expression of TNNT2, a gene encoding one of the major sarcomere proteins mediating cardiomyocyte contractility and located within the gained chromosome 1q region. Moreover, the variant hPSC-CMs showed altered contraction kinetics. Together these results highlight the importance of careful monitoring of chromosome aberrations in hPSC lines as these could have confounding effects in various applications such as disease modelling and drug discovery.

cell biology↗

STRAIGHT-IN: A platform for high-throughput targeting of large DNA payloads into human pluripotent stem cells

Inserting large DNA payloads (>10 kb) into specific genomic sites of mammalian cells remains challenging. Applications ranging from synthetic biology to evaluating the pathogenicity of disease-associated variants for precision medicine initiatives would greatly benefit from tools that facilitate this process. Here, we merge the strengths of different classes of site-specific recombinases and combine these with CRISPR/Cas9-mediated homologous recombination to develop a strategy for stringent site-specific replacement of genomic fragments at least 50 kb in size in human induced pluripotent stem cells (hiPSCs). We demonstrate the versatility of STRAIGHT-IN (Serine and Tyrosine Recombinase Assisted Integration of Genes for High-Throughput INvestigation) by: (i) inserting various combinations of fluorescent reporters into hiPSCs to assess excitation-contraction coupling cascade in derivative cardiomyocytes, and; (ii) simultaneously targeting multiple variants associated with inherited cardiac arrhythmic disorder into a pool of hiPSCs. STRAIGHT-IN offers a precise approach to generate genetically-matched panels of hiPSC lines efficiently and cost-effectively.

cell biology↗

Cryopreservation of human pluripotent stem cell-derived cardiomyocytes is not detrimental to their molecular and functional properties

Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) have emerged as a powerful platform for in vitro modelling of cardiac diseases, safety pharmacology, and drug screening. All these applications require large quantities of well-characterised and standardised batches of hiPSC-CMs. Cryopreservation of hiPSC-CMs without affecting their biochemical or biophysical phenotype is essential for facilitating this, but ideally requires the cells being unchanged by the freeze-thaw procedure. We therefore compared the in vitro functional and molecular characteristics of fresh and cryopreserved hiPSC-CMs generated from two independent hiPSC lines. While the frozen hiPSC-CMs exhibited poorer replating than their freshly-derived counterparts, there was no difference in the proportion of cardiomyocytes retrieved from the mixed population when this was factored in. Interestingly, cryopreserved hiPSC-CMs from one line exhibited longer action potential durations. These results provide evidence that cryopreservation does not compromise the in vitro molecular, physiological and mechanical properties of hiPSC-CMs, though can lead to an enrichment in ventricular myocytes. It also validates this procedure for storing hiPSC-CMs, thereby allowing the same batch of hiPSC-CMs to be used for multiple applications and evaluations.

cell biology↗

Versatile open software to quantify cardiomyocyte and cardiac muscle contraction in vitro and in vivo

Contraction of muscle reflects its physiological state. Methods to quantify contraction are often complex, expensive and tailored to specific models or recording conditions, or require specialist knowledge for data extraction. Here we describe an automated, open-source software tool (MUSCLEMOTION) adaptable for use with standard laboratory and clinical imaging equipment that enables quantitative analysis of normal cardiac contraction, disease phenotypes and pharmacological responses. MUSCLEMOTION allowed rapid and easy measurement of contractility in (i) single cardiomyocytes from primary adult heart and human pluripotent stem cells, (ii) multicellular 2D-cardiomyocyte cultures, 3D engineered heart tissues and cardiac organoids/microtissues in vitro and (iii) intact hearts of zebrafish and humans in vivo. Good correlation was found with conventional measures of contraction in each system. Thus, using a single method for processing video recordings, we obtained reliable pharmacological data and measures of cardiac disease phenotype in experimental cell- and animal models and human echocardiograms.

physiology↗