Search bioRxiv⌕ Search

Biology subjects

Moazen, M.

Publications and source records attributed to Moazen, M..

5 recordsLinked to original sources

A Novel Computational Framework to Investigate the Biomechanics of Burrowing

Head-first burrowing likely imposes strong mechanical demands on the skull of fossorial vertebrates, but how cranial tissues respond to these loads remains obscure. Here, we developed a computational framework integrating the discrete element method (DEM) with finite element analysis (FEA) to investigate cranial biomechanics during burrowing. We used Blanus cinereus, a round-headed amphisbaenian, as a model to establish DEM predictions that were validated and calibrated against in vitro experiments across three substrates and compared with in vivo push forces. DEM-calibrated particle contact forces were then transferred to an anatomically detailed finite element model to quantify cranial loading. The analyses suggested that soft tissues accommodated substantial deformation, while the skull transmitted burrowing loads from the premaxilla towards the occipital region. Cranial sutures further redistributed stresses and strains within the skull. This validated DEM-FEA framework links particle-scale substrate interactions with internal cranial biomechanics and provides a quantitative approach for investigating the mechanics of head-first burrowing across fossorial vertebrates.

bioengineering↗

Effects of Mechanical Loading on Cranial Joint Mesenchymal Stem Cell Proliferation

Sutures are the primary sites of cranial bone growth, allowing the skull to accommodate the growing brain. External mechanical stimulus has been shown to delay suture fusion and induce tissue remodelling. Recent studies suggest that in vivo cyclic bone loading increased proliferation of mesenchymal stem cells (MSC) in the coronal suture. The overall aim of this study was to understand how many loading sessions (exposure-response) and how long after loading (time-course) did MSC proliferation increase in the coronal suture. In the exposure-response analysis, mice underwent 1, 3, or 5 loading sessions between Postnatal day 7 (P7) and P11, and in the time-course analysis, treated mice underwent 10 loading sessions between P7 and P21. Loading sessions were 10 minutes at a frequency of 1 Hz and a force of 10 g (0.1 N). The loading tip was positioned on the posterior aspect of the left frontal bone, dorsal to the coronal suture. The EdU marker shows a statistically significant increase in proliferation after one loading session and a decrease after three loading sessions. The PCNA marker shows a statistically significant increase after three and five loading sessions. The exposure-response analysis showed that when the results of both markers are combined, levels of proliferation cannot be interpreted until at least five loading sessions have been completed, after which a clear increase in proliferation was observed. In the time-course analysis, proliferation was highest immediately after the final treatment session and 24 hours after the final loading session the effects of mechanical bone loading gradually returned to baseline.

Developmental Biology↗

Resolving near-micron scale features within a whole sheep head using Hierarchical Phase-Contrast Tomography

BackgroundHierarchical Phase-Contrast Tomography (HiP-CT) was developed to image ex vivo intact human soft-tissue organs with local near-micron scale resolution. PurposeWe demonstrate the application of HiP-CT in combination with the recently developed Eikonal Phase Retrieval (EPR) for resolving anatomical features in large hard and soft tissue structures on a sheep head, and show the applicability for zooming to resolve anatomical features with near-micron scale resolution. Materials and MethodsWe imaged an entire skinned sheep head prepared in 70 % ethanol with HiP-CT at an isotropic voxel size of 16.5 {micro}m using the recently developed Eikonal Phase Retrieval (EPR) to reduce artefacts from bones. Local tomography zooms were taken in regions of interest: the eye (4.23 {micro}m voxels) and the coronal suture (2.20 {micro}m voxels). To compare to clinical imaging, we acquired T2-weighted MRI and CT of the sheep head and evaluated the contrast-to-noise ratio for differentiation of white and grey matter in the brain for all modalities. Further evaluations on HiP-CT images include structure tensor analysis for structural orientation in the brain as well as fibre tracking in the coronal suture. ResultsHiP-CT combined with EPR achieved high contrast for both hard and soft tissue. Comparison to MRI showed similar soft-tissue contrast, but much higher spatial resolution. Structure tensor analysis in the brain revealed the orientation of the major white matter bundles. In the eye, near-micron scale features such as retinal layers and the bundles in the optic nerve were visualized. Fiber tracking allowed analysis of the orientation of collagen fiber bundles in the coronal suture. ConclusionThis work highlights the potential of HiP-CT to image a complete sheep head, ex vivo, and hierarchically zoom without sectioning to resolve few-microns features locally, enabling comprehensive three-dimensional visualization of intricate cranial structures and their spatial interrelations. Summary statementTechnical developments in HiP-CT enable ex vivo X-ray imaging of an intact sheep head with local resolution to near-micron scale, demonstrating future viability on a human head. Key resultsO_LIA whole sheep head was imaged with synchrotron-based hierarchical phase-contrast tomography coupled with Eikonal Phase-retrieval with 16.5 {micro}m isotropic voxels. C_LIO_LIThe high contrast for both hard and soft tissue enabled differentiation of brain white and grey matter, the optic nerve and bone features within the skull. C_LIO_LILocal tomography zoom scans in an eye (4.23 {micro}m voxels) and coronal suture (2.20 {micro}m voxels) allowed visualization and analysis of near-micron sized features. C_LI

bioengineering↗

Hindlimb kinematics, kinetics, and muscle dynamics during sit-to-stand and sit-to-walk transitions in emus (Dromaius novaehollandiae)

Animals not only need to walk and run but also lie prone to rest and then stand up. Sit-to-stand (STS) and sit-to-walk (STW) transitions are vital behaviours little studied in species other than humans so far, but likely impose biomechanical constraints on limb design because they involve near-maximal excursions of limb joints that should require large length changes and force production from muscles. By integrating data from experiments into musculoskeletal simulations, we analysed joint motions, ground reaction forces, and muscle dynamics during the STS and STW transitions in a large terrestrial, bipedal, and cursorial bird: the emu (Dromaius novaehollandiae, [~] 30 kg). Simulation results suggest that in both STS and STW, emus operate near the functional limits ([~] 50 % of shortening/lengthening) of some of their hindlimb muscles, particularly in distal muscles with limited capacity for length change and leverage. Both movements involved high muscle activations (> 50 %) and force generation of major joint extensor muscles early in the transition. STW also required larger net joint moments and non-sagittal motions, entailing greater demands for muscle capacity. Whilst our study involves multiple assumptions, our findings lay the groundwork for future studies to understand, for example, how tendon contributions may reduce excessive muscle demands, especially in the distal hindlimb. As the first investigation into how an avian species stands up, this study provides a foundational framework for future comparative studies investigating organismal morphofunctional specialisations and evolution, offering potential robotics and animal welfare applications. Summary statementThe study demonstrates the dynamics, biomechanical constraints, and musculotendinous control strategies during the sit-to-stand/walk transitions for a large bipedal bird - the emu - informing morphology, evolution, and potential robotic applications.

zoology↗

The mechanobiology of craniosynostosis in Crouzon syndrome

Children with syndromic forms of craniosynostosis undergo a plethora of surgical interventions to resolve the clinical features caused by the premature fusion of cranial sutures. While surgical correction is reliable, the need for repeated rounds of invasive treatment puts a heavy burden on the child and their family. This study explores a non-surgical alternative using mechanical loading of the cranial joints to prevent or delay craniofacial phenotypes associated with Crouzon syndrome. We treated Crouzon syndrome mice before the onset of craniosynostosis by cyclical mechanical loading of cranial joints using a custom designed set-up. Cranial loading applied to the frontal bone partially restores normal skull morphology, significantly reducing the typical brachycephalic appearance. This is underpinned by the delayed closure of the coronal suture and of the intersphenoidal synchondrosis. This study provides a novel treatment alternative for syndromic craniosynostosis which has the potential to be an important step towards replacing, reducing or refining the surgical treatment of all craniosynostosis patients.

biophysics↗