Search bioRxiv⌕ Search

Biology subjects

Mellot, A.

Publications and source records attributed to Mellot, A..

2 recordsLinked to original sources

Harmonizing and aligning M/EEG datasets with covariance-based techniques to enhance predictive regression modeling

Neuroscience studies face challenges in gathering large datasets, which limits the use of machine learning (ML) approaches. One possible solution is to incorporate additional data from large public datasets; however, data collected in different contexts often exhibit systematic differences called dataset shifts. Various factors, e.g., site, device type, experimental protocol, or social characteristics, can lead to substantial divergence of brain signals that can hinder the success of ML across datasets. In this work, we focus on dataset shifts in recordings of brain activity using MEG and EEG. State-of-the-art predictive approaches on M/EEG signals classically represent the data by covariance matrices. Model-based dataset alignment methods can leverage the geometry of covariance matrices, leading to three steps: recentering, re-scaling, and rotation correction. This work explains theoretically how differences in brain activity, anatomy, or device configuration lead to certain shifts in data covariances. Using controlled simulations, the different alignment methods are evaluated. Their practical relevance is evaluated for brain age prediction on one MEG dataset (Cam-CAN, n=646) and two EEG datasets (TUAB, n=1385; LEMON, n=213). When the target sample included recordings from the same subjects with a different task among the same dataset, paired rotation correction was essential ([Formula] (rest-passive) or +0.17 (rest-smt)). When the target dataset included new subjects and a new task, re-centering led to improved performance ([Formula] for rest-passive, [Formula] for rest-smt). For generalization to an independent dataset sampled from a different population and recorded with a different device, re-centering was necessary to achieve brain age prediction performance close to within domain prediction performance. This study demonstrates that the generalization of M/EEG-based regression models across datasets can be substantially enhanced by applying domain adaptation procedures that can statistically harmonize diverse datasets.

neuroscience↗

A reusable benchmark of brain-age prediction from M/EEG resting-state signals

Population-level modeling can define quantitative measures of individual aging by applying machine learning to large volumes of brain images. These measures of brain age, obtained from the general population, helped characterize disease severity in neurological populations, improving estimates of diagnosis or prognosis. Magnetoencephalography (MEG) and Electroencephalography (EEG) have the potential to further generalize this approach towards prevention and public health by enabling assessments of brain health at large scales in socioeconomically diverse environments. However, more research is needed to define methods that can handle the complexity and diversity of M/EEG signals across diverse real-world contexts. To catalyse this effort, here we propose reusable benchmarks of competing machine learning approaches for brain age modeling. We benchmarked popular classical machine learning pipelines and deep learning architectures previously used for pathology decoding or brain age estimation in 4 international M/EEG cohorts from diverse countries and cultural contexts, including recordings from more than 2500 participants. Our benchmarks were built on top of the M/EEG adaptations of the BIDS standard, providing tools that can be applied with minimal modification on any M/EEG dataset provided in the BIDS format. Our results suggest that, regardless of whether classical machine learning or deep learning was used, the highest performance was reached by pipelines and architectures involving spatially aware representations of the M/EEG signals, leading to R^2 scores between 0.60-0.71. Hand-crafted features paired with random forest regression provided robust benchmarks even in situations in which other approaches failed. Taken together, this set of benchmarks, accompanied by open-source software and high-level Python scripts, can serve as a starting point and quantitative reference for future efforts at developing M/EEG-based measures of brain aging. The generality of the approach renders this benchmark reusable for other related objectives such as modeling specific cognitive variables or clinical endpoints. Highlights- We provide systematic reusable benchmarks for brain age from M/EEG signals - The benchmarks were carried out on M/EEG from four countries > 2500 recordings - We compared machine learning pipelines capable of handling the non-linear regression task of relating biomedical outcomes to M/EEG dynamics, based on classical machine learning and deep learning - Next to data-driven methods we benchmarked template-based source localization as a practical tool for generating features less affected by electromagnetic field spread - The benchmarks are built on top of the MNE ecosystem and the braindecode package and can be applied on any M/EEG dataset presented in the BIDS format

neuroscience↗