Search bioRxiv⌕ Search

Biology subjects

Mellor, S. J.

Publications and source records attributed to Mellor, S. J..

5 recordsLinked to original sources

Magnetoencephalography Without a Shielded Room

Magnetoencephalography (MEG) offers non-invasive neuroimaging with high temporal and spatial precision - but its adoption is hampered by the prohibitive cost and infrastructure burden of a magnetically shielded room. We have overcome that burden and present a lightweight, low-cost, multichannel magnetoencephalography system that can image brain activity without needing a magnetically shielded room. The multichannel nature of the system facilitates not just detection but also localization of brain signals that are over 300 million times smaller than environmental interference, without requiring passive shielding. Our system weighs less than 75kg, more than 100 times lighter than a typical shielded room. This is made possible through low-cost active shielding and software-based spatial filtering. We also show that the signal to noise ratio of our in-vivo recordings is comparable to what can be obtained from a conventional cryogenically-cooled MEG system sited within a shielded room. This demonstration is a crucial step towards democratizing magnetoencephalography and making it a globally accessible neuroimaging technology for healthcare and discovery research.

neuroscience↗

Wearable MEG data recorded during human stepping

Non-invasive spatiotemporal imaging of brain activity during large-scale, whole body movement is a significant methodological challenge for the field of movement neuroscience. Here, we present a dataset recorded using a new imaging modality - optically-pumped magnetoencephalography (OP-MEG) - to record brain activity during human stepping. Participants (n=3) performed a visually guided stepping task requiring precise foot placement while dual-axis and triaxial OP-MEG and leg muscle activity (electromyography, EMG) were recorded. The dataset also includes a structural MRI for each participant and foot kinematics. We validate the fidelity of the OPM data by showing movement-related beta band desynchronization source localised to the primary motor cortex. This multimodal dataset offers a resource for methodological development and testing for OPM data (e.g., movement-related interference rejection), within-subject analyses, and exploratory analyses to generate hypotheses for further work on the neural control of human stepping.

neuroscience↗

Non-invasive evidence for rhythmic interactions between the human brain, spinal cord, and muscle

Voluntary human movement relies on interactions between the spinal cord, brain, and sensory afferents. The integrative function of the spinal cord has proven particularly difficult to study directly and non-invasively in humans due to challenges in measuring spinal cord activity. Investigations of sensorimotor integration often rely on cortico-muscular coupling, which can capture interactions between the brain and muscle, but cannot reveal how the spinal cord mediates this communication. Here, we introduce a system for direct, non-invasive imaging of concurrent brain and cervical spinal cord activity in humans using optically-pumped magnetometers (OPMs). We used this system to study endogenous interactions between the brain, spinal cord, and muscle involved in sensorimotor control during simple maintained contraction. Participants (n=3) performed a hand contraction with real-time visual feedback while we recorded brain and spinal cord activity using OPMs and muscle activity using EMG. We first identify the part of the spinal cord exhibiting a peak in estimated current flow in the cervical region during contraction. We then demonstrate that rhythmic activity in the spinal cord exhibits significant coupling with both brain and muscle activity in the 5-35 Hz frequency range. These findings evidence the possibility of concurrent spatio-temporal imaging along the entire neuro-axis.

neuroscience↗

Using OPMs to measure neural activity in standing, mobile participants

Optically pumped magnetometer-based magnetoencephalography (OP-MEG) can be used to measure neuromagnetic fields while participants move in a magnetically shielded room. Head movements in previous OP-MEG studies have been up to 20 cm translation and [~]30{degrees} rotation in a sitting position. While this represents a step-change over stationary MEG systems, naturalistic head movement is likely to exceed these limits, particularly when participants are standing up. In this proof-of-concept study, we sought to push the movement limits of OP-MEG even further. Using a 90 channel (45-sensor) whole-head OP-MEG system and concurrent motion capture, we recorded auditory evoked fields while participants were: (i) sitting still, (ii) standing up and still, and (iii) standing up and making large natural head movements continuously throughout the recording - maximum translation 120 cm, maximum rotation 198{degrees}. Following pre-processing, movement artefacts were substantially reduced but not eliminated. However, upon utilisation of a beamformer, the M100 event-related field localised to primary auditory regions. Furthermore, the event-related fields from auditory cortex were remarkably consistent across the three conditions. These results suggest that a wide range of movement is possible with current OP-MEG systems. This in turn underscores the exciting potential of OP-MEG for recording neural activity during naturalistic paradigms that involve movement (e.g. navigation), and for scanning populations who are difficult to study with stationary MEG (e.g. young children).

neuroscience↗

Magnetic Field Mapping and Correction for Moving OP-MEG

BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.

neuroscience↗