Search bioRxiv⌕ Search

Biology subjects

McCarthy, K. J.

Publications and source records attributed to McCarthy, K. J..

2 recordsLinked to original sources

Lipin-1-cardiolipin axis sustains mitochondrial respiration and efferocytosis in macrophages

Defective macrophage clearance of apoptotic cells contributes to persistent inflammation and cardiometabolic disease. Efferocytosis requires mitochondrial oxidative metabolism, but how macrophages maintain respiratory capacity during resolution remains unclear. Here, we show that lipin-1 supports efferocytosis through a cardiolipin-associated mitochondrial program. In IL-4-stimulated macrophages, lipin-1 deficiency reduced cardiolipin abundance and selectively lowered the abundance of inner mitochondrial membrane proteins, including respiratory-chain components, consistent with decreased mitochondrial respiratory capacity. These defects occurred without broad suppression of canonical metabolic transcriptional programs, and experimentally altering mitochondrial morphology failed to reproduce or rescue the functional phenotype. Disrupting cardiolipin synthesis impaired efferocytosis, whereas the cardiolipin-interacting peptide SS-31 improved mitochondrial respiration and apoptotic-cell clearance in lipin-1-deficient macrophages. Systemic SS-31 treatment also reduced apoptotic-cell accumulation after dexamethasone-induced thymic injury. Together, these findings implicate cardiolipin homeostasis in lipin-1-dependent macrophage bioenergetics and efferocytosis, identifying a potentially actionable pathway while leaving the mechanism connecting lipin-1 to cardiolipin abundance unresolved.

immunology↗

Strategic Debulking of the Femoral Stem Promotes Load Sharing Through Controlled Flexural Rigidity of the Implant Wall: Optimization of Design by Finite Element Analysis.

Hip arthroplasty prostheses are often constructed of metal alloys, and the inherent disparity in the modulus of elasticity between the implant and the femur is attributed to the altered stress-strain pattern in adjacent bone. Rigid implants shield surrounding bone from mechanical loading, and the reduction in skeletal stress required to maintain bone mass and density results in accelerated bone loss, the forerunner to implant loosening and implant failure. Femoral stems of various geometric profiles and surface modifications, materials and material distributions for graded functionality, and porous stem structures have been investigated to achieve mechanical properties of stems that are closer to bone to mitigate stress shielding. For improved load transfer from implant to femur, the proposed study investigated a strategic debulking effort to impart controlled flexibility while retaining sufficient strength and endurance properties of the femoral stem. Using an iterative design process, debulked configurations based on an internal skeletal truss framework were evaluated using finite element analysis as outlined in ISO 7206 standards, with implants offset in natural femur or potted in testing cylinders. The commonality across the debulked designs was the minimization of proximal stress shielding compared to conventional solid implants. Stem topography can influence performance, and the truss implants with and without the calcar collar were evaluated. Load sharing was equally effective irrespective of the collar however, the collar was critical to reducing the stresses in the implant. When bonded directly to bone or cemented in the femur, the truss stem was effective at limiting stress shielding. Nevertheless, a localized increase in principal stress at the lateral proximal junction could negatively affect cement integrity and the bonding of cemented implants. The study determined that superior biomechanical performance of the truss implant is realized with a collared stem that is placed in an interference fit. Mechanistically, the controlled accommodation of deformation of the implant wall provides contextual flexibility and load sharing characteristics to the truss implant.

bioengineering↗